Technical Information
Halogen reflector lamp for line voltage
HALOPAR 30
Product characteristics:
UV
UV
UVUV
Fi
Fillllte
ter
FiFi
terte
• Halogen lamp for line voltage without
need of transformer.
• 15% energy savings in comparison to
conventional reflector lamps.
• Brillant, white halogen light.
ALU
• Burner with UV-filter glass. Meets the
most stringent UV protection thresholds
(NIOSH). Reduction of bleaching effect.
COOL BEAM
• Open operation permitted acc. to IEC
60598-1.
• Cut glass reflector optional in aluminium
or cool-beam version.
Cool-beam reflectors carry off thermal
radiation to the back of the lamp, so they
are especially appropriate for illuminating
thermally susceptible objects.
Range:
Order-code
64841 SP (Alu)
64841 FL (Alu)
64845 SP (CB)
64845 FL (CB)
* Maximum permitted tol erance nominal value +8% acc. to IEC 60357.
Voltage Wattage* Luminous
intensity
230/240V 75W 6900 cd 10° 2000h HAGS/UB-75-230-E27-97/10
„ „ 2200 cd 30° „ HAGS/UB-75-230-E27-97/30
„ „ 7500 cd 10° „ HRGS/UB-75-230-E27-97/10
„ „ 2400 cd 30° „ HRGS/UB-75-230-E27-97/30
Beam
angle
Lampe life ILCOS-code
HAL M-M, Edition 10/03
Subject to alteration 1/3

Light data:
Maintenance
Colour temperature
UV-radiation
Light distribution
Geometry:
Technical Information
Halogen reflector lamp for line voltage
HALOPAR 30
Decrease of axial luminous intensity <20% after 75% of the nominal life time.
ALU: 2900 K ± 100
CB: 2950 K ± 100
The irradiance is clear below the NIOSH-threshold values for skin and eye.
Due to the cover lens the bleaching effect is clear reduced ( depending on the radiated
material! ).
Available on the Light programm CD-ROM, in the directory “Eulumdat”.
D
L
Values in mm Desig. HALOPAR 30
Overall length L max. 90,5 mm
Refl. diameter D max. 97,0 mm
Please note:
!
Dimensions and tolerances are subject to change within the IEC regulations!
Not explicitly given dimensions cannot be evaluated out of measuring lamp samples!
HAL M-M, Edition 10/03
Subject to alteration 2/3

Technical Information
Halogen reflector lamp for line voltage
HALOPAR 30
Temperature behaviour:
Max. permitted temperature
!
Operating conditions:
Burning position
Areas of application HALOPAR 30 is not suitable for exterior use.
Dimmable
Safety distance
!
Environmental
sensitivity:
Validity:
Burning position
acc. to 60432 - 1
Operating Temperature; free burning
75W
Measurement conditions:
Measurement in the mos t unfavourable burning position for the lamp.
Surrounding temperature: 25°C (ac c. to DIN 5032)
Voltage: 230V
Operating temperature for free burning use is not obliging and is useful for orientation
only.
any
100%
According to IEC 60598-1 "minimum safety distance" the max. temperature permitted on the
illuminated area is 90°C. This max. temperature has to be ensured by the minimum distance.
This distance has to be determined through the luminaire manufacturer by appropriate
measurements.
HALOPAR 30 be disposed as household waste.
These technical information sheets (TI-sheets) are updated in irregular intervals. The user is
responsible to ensure that the information they have is up to date and still valid. Once a new TIsheet has been issued, former editions are to be seen as invalid and disposed of.
Cap temperature
Base up
210°C
175°C
HAL M-M, Edition 10/03
Subject to alteration 3/3