The irradiance is clear below the NIOSH-threshold values for skin and eye.
Due to the integrated cover pan the bleaching is clear reduced (depending on radiated material).
Light distribution
Available on the Light programm CD-ROM, in the directory “Eulumdat”.
HAL M-M Edition 2/04; 2/4
Subject to alteration
Geometry:
Technical Information
Compact halogen line voltage reflector lamp
HALOPAR 16
N
N
D
S
GU 10 GZ 10
Distance of the pins Ds
Values in mm HALOPAR 16 (GU/GZ10) Nomin. IEC Norm
L
D
S
10 ± 0,2
L
10
Overall length L max. 55 Length of reflector N max. 46 44 – 47,5
Diameter of reflector ∅ D
max. 50,7 49,4 – 50,7
∅
∅
D
∅∅
D
∅∅∅∅
L
Values in mm HALOPAR 16 (E14) Nomin. IEC Norm
Overall length L max. 75 -
Diameter of reflector ∅ D
max. 50,7 49,4 – 50,7
Please note:
Dimensions and tolerances are subject to change within the IEC regulations! Not explicitly
given dimensions cannot be evaluated by measuring lamp samples!
*Special foils in the pi nch allow higher temperatures than IEC 60357.
Base up Base up Base up Base up Base up
370°C* 250°C 240°C - 210°C
Operating temperature; free burning
Reflector
(at the high of
filament)
Measurement conditions:
Measurement in the most unfavourable burning position for the pinch
Surrounding temperature: 25°C (acc. to DIN 5032)
Voltage: 230V
Operating temperatures for free burning use are not obliging and are useful for orientation only.
Operating conditions:
Burning position
any
Areas of application
For outdoor applications and operation in damp locations special approved fixtures are required.
Dimmable
100%
Safety informations
According to IEC 60598-1/DIN VDE 0711 "minimum security distance" the max. temperature
permitted is 90°C. This max. temperature has to be ensured by the minimum distance. This
distance has to be determined through the luminaire manufacturer by appropriate measurements and specified on the luminaire.
Environmental
sensitivity:
HALOPAR 16 can be disposed of as household waste.
Validity:
These technical information sheets (TI-sheets) are updated in irregular intervals. The user is
responsible to ensure that the information they have is up to date and still valid. Once a new TIsheet has been issued, former editions are to be seen as invalid and disposed of.
max. cap tempera-
(acc. to IEC 60432-1,
Annex K)
ture
HAL M-M Edition 2/04; 4/4
Subject to alteration