Osram EN-WS-2B-GB2-WH, EN-WS-SC5-GB2-WH, EN-WS-ZC3-GB2-WH, EN-WS-SC3-GB2-WH, EN-WS-ZC6-GB2-WH Wiring And Installation Manual

Page 1
Low-Voltage Wallstations
Wiring and installation manual
www.osram.us
Light is OSRAM
Page 2
Overview
The Low-voltage Wallstations with integrated LED indicators are available in a range of configurations for customized light level control. This low-voltage Wall­station obtains its operating power via GreenBus II® cable and features several options for functionality depending on the model installed.
The low-voltage wallstation obtains its address during the commissioning process and no actions are required during installation.
Important Safeguards
Note
Tip
!
STOP
When using electrical equipment, basic safety precautions should always be followed including the following:
— READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
— Do not mount near gas or electric heaters.
— Equipment should be mounted in locations and at heights where it will not
readily be subjected to tampering by unauthorized personnel.
— The use of accessory equipment is not recommended by OSRAM as it may
cause an unsafe condition.
— Do not use this equipment for other than the intended use.
Note
Tip
!
STOP
SAVE THESE INSTRUCTIONS
Low-voltage Works with ENCELIUM® Works with ENCELIUM EDGE™ Wallstation Ordering Code EXTEND Networked LMS Standalone LMS
2-But ton EN-W S-2B-GB2-WH X X 3-Scene EN-W S-SC3-GB2-W H X X 5-Scene EN-WS-SC5-GB2-WH X X 3-Zone EN-W S-ZC3-GB2-WH X 6-Zone EN-W S-ZC6 -GB2-WH X
2
Page 3
GreenBus II® Wiring
Communication Circuit: 24Vdc, Class 2
GreenBus II is a low-cost, high reliability communication standard used to report occupancy status signals, daylight readings and user inputs received via Wallstations to the ENCELIUM® EXTEND Networked Light Management System or the ENCELIUM EDGE™ Standalone Wireless Light Management System for the purpose of obtaining optimum brightness settings for an individual light fixture or a group of light fixtures.
When used in the ENCELIUM EXTEND Networked Light Management System, the GreenBus II wiring originates at an ENCELIUM EXTEND Manager and propagates in a daisy-chain or “T” fashion from device to device (or other compatible equipment).
When used in the ENCELIUM EDGE Standalone Wireless Light Management System, the GreenBus II wiring is used to connect a low-voltage wallstation directly to a Wireless Area Light Control Module (WALC).
Note
Tip
!
STOP
GreenBus II is an proprietary standard and proprietary connectors and jacks are used for ease of installation only.
Connect to the ENCELIUM EXTEND Networked Light Management System or the ENCELIUM EDGE Standalone Wireless Light Management System only. DO NOT CONNECT TO OTHER CIRCUITS.
GreenBus II must be laid out as per supplied system layout drawing. If changes are required, determine an optimum wiring path utilizing the supplied prefabricated cables, based on the position of light fixtures, sensors and Wallstations. The number of modules on each chain is limited since the modules obtain power via the GreenBus II cable.
Notes
— When used in the ENCELIUM EXTEND
Networked Light Management System, it is suggested to leave room for future system upgrades and to limit the number of modules per GreenBus II channel to 80 during initial installation.
GreenBus II wires can be inserted into either of the 2 ports. Press the corresponding button to insert the wires.
— Both ports may be used when connecting in a daisy-chain fashion
(e.g. ENCELIUM EXTEND Networked Light Management System device). To remove the wires, press the corresponding button and pull the wires out while rotating them in a circular motion.
3
Push Button Terminal Block
*Pair 2
*Pair 1
Faceplate
GreenBus II wires (Pairs 1 & 2) should not be crossed.
GreenBus II wires are polarity independent.
A shor t GreenBus II jumper can be used to interconnect ganged wallstations.
Page 4
Mounting bracket Old Work Low Voltage Mounting Bracket
Low Voltage Device Box:
4
Mounting bracket J-Box
Wallstation Installation
Electrical Metal Device Box:
Install the mounting bracket using the supplied screws. Ensure that the OSRAM logo and SINGLE GANG labels are facing up.
Page 5
Decorator Plate Installation
The low-voltage wallstation can also be installed with an off-the-shelf decorator-style wall plate. Multi-gang wallstation installations require multi-gang decorator wall plates.
Remove the button assembly from the OSRAM wall plate. This can be achieved by pressing the wall plate with your thumbs near the button assembly while grasping the OSRAM Wall Plate.
5
Wallstation Installation (continued)
Place the wallstation assembly into the mounting plate and push gently until ‘clicks’ are heard. This confirms that the pieces are secured.
Page 6
Orient the mounting bracket such that the DECORATOR and MULTI GANG labels are facing up. Insert the wallstation button assembly into the mounting plate until ‘clicks’ are heard. Clicks confirm that the pieces are secured.
Install the mounting bracket using the supplied screws. Install the decorator plate using screws supplied with the decorator plate.
6
Decorator Plate Installation (continued)
Install the supplied wall strips to the button assembly until they snap in.
Page 7
Installation Notes
Consult the OSRAM website for the most up-to-date version of the GreenBus II® system design guide and install this product according to the guidelines.
The Wallstation is to be installed in dry, indoor locations ONLY. Do not install the Wallstation in damp locations. Damp locations are defined as: interior locations subject to moderate degrees of moisture, such as basements, barns, cold-storage warehouses, as well as partially protected locations under canopies, marquees and open roofed porches.
Troubleshooting
There are no user-serviceable parts inside the Wallstation. Please return the device to OSRAM if service is required.
Regulatory Approvals
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under FCC rules.
This equipment has been tested and found to comply with Industry Canada ICES-003 Issue 5 (CAN ICES-3 (A)/NMB-3(A)).
Contains FCC ID: H79DFZM-E7220 Contains IC ID: 4259B-DFZM7220
7
Page 8
© 2018 OSRAM SYLVANIA Inc.
LM S135R 2 4-18
OSRAM SYLVANIA Inc.
200 Ballardvale Street
Wilmington, MA 01887 USA
888-531-7573
www.osram.us/ds