OSRAM DALI MCU User Manual

DALI MCU
da+
da-LN
Digital potentiometer Fitting instructions
Description
A
Purpose and application
The DALI MCU digital potentiometer controls up to 25 DALI electronic control gears and enables the manual operation of luminaires with a DALI interface.
The potentiometer is mounted in ush device boxes.
Function
The potentiometer converts rotations of and pressure on the
rotary knob into DALI commands.
By switching multiple DALI MCU in parallel, the number of con­trol locations or the number of controllable luminaires can be in­creased. If multiple potentiometers are switched in parallel, the commands of the potentiometer actuated last apply. Automatic synchronization makes it possible to change the control location without disturbing effects (e.g. brightness uctuations).
The DALI MCU can be supplied directly from the DALI control line (= passive operation) or can deliver the required control current itself when connected to the mains voltage (= active
operation).
Design
The potentiometer is made up of the following components:
Rotary potentiometer (A)
Connections (B)
Control line (da+, da–)
– Neutral conductor (N)
Phase (L)
• Housing with rotary knob (C)
C
Installation
B
Safety instructions
The potentiometer must only be installed and put into operation by a qualied electrician. The applicable safety regulations and
accident prevention regulations must be observed.
WARNING!
Exposed, live cables.
Danger of electric shock!
• Only work on the potentiometer when it is de-
energised.
CAUTION!
Destruction of the potentiometer and other devices through incorrect mounting!
• The potentiometer is designed for mounting in ush device boxes. If mounted elsewhere, provi­deadequate cable strain relief and insulation.
• Do not wire the control line with an external volt­age, especially not a mains voltage of 230 V.
• Do not exceed the maximum number of ECGs and total line length.
IV 2009
DALI_MCU_ma0904en_we1.01.indd
OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC)
Steinerne Furt 62 86167 Augsburg Germany
Tel : +49 (0) 1803 677 - 200 (kostenpichtig / charges apply) Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de
40083211897216
4008321189721
Continued on the back page!
Installation (cont.)
da
+
da
-
L
N
L
N
DALI EVG
~
~
da
da
L
N
da
+
da
-
L
N
DALI EVG
~
~
da
da
L
N
da+
da-LN
71
71
51
32
4
Connecting the potentiometer
To control DALI ECGs, a maximum of 4 active potentiometers
can be connected in parallel.
C
D
• 1 active potentiometer: max. 25 ECGs
• 2 active potentiometers: max. 50 ECGs
• 3 active potentiometers: max. 75 ECGs
4 active potentiometers: max. 100 ECGs
C Active potentiometer (with mains connection)
D Passive potentiometer (without mains connection)
Appendix
Technical data
Operating voltage 230 V AC, 50-60 Hz
Maximum total length of
signal line
DALI connection Max. 25 DALI ECG with one
Maximum power consump­tion
Permissible line cross section
Permissible ambient tem­perature
300 m
active DALI MCU
3 W
1 – 4 mm²
0 °C to 50 °C
Protection type IP 20
Protection class II
Dimensions Flush-mounted part (Ø x H):
51 x 32 mm Mounting plate (L x W): 71 x 71 mm
Dimensions
The requirements as per EN 60928 und EN 61547 are fullled.
Conformity with the relevant EU directives is conrmed by the CE symbol.