Congratulations on choosing a ADB product! We thank you for your custom.
Please note that this product, as all the others in the rich ADB range, has been designed and made with total quality to ensure
excellent performance and best meet your expectations and requirements.
INDEX
1. SAFETY INSTRUCTION
2. TECHNICAL SPECIFICATIONS
3. THE UNIT CONSTRUCTION
4. INSTALLATION
5. POWER
6. CONTROL PANEL
7. MAIN FUNCTION
8. HOW TO CONTROL THE UNIT
8.1 DMX Address Setting
8.2 DMX Configuration
8.3 DMX Connection
9. TROUBLESHOOTING
10. FIXTURE CLEANING
LEXPERT PROFILE L
2
1. SAFETY INFORMATION
EN
IT
DE
ES
How to get your SAFETY INSTRUCTIONS in multilingual version.
You may always download the multilingual Safety Instruction manual for
this ADB product from:
www.adbstagelight.com
if: FIS00X - Safety Information LEXPERT PROFILE L
R
Come ottenere le INFORMAZIONI DI SICUREZZA nella versione
multilingue.
Puoi sempre scaricare la versione multilingue delle Informazioni di
Sicurezza per questo prodotto ADB al seguente link:
www.adbstagelight.com
Rif: FIS00X - Safety Information LEXPERT PROFILE L
So erhalten Sie Ihr INFORMATIONEN ZUR SICHERHEIT in der
mehrsprachigen Version.
Sie können die mehrsprachige Version des Handbuchs mit
Sicherheitshinweisen für dieses ADB Produkt unter folgendem Link
herunterladen:
www.adbstagelight.com
Rif: FIS00X - Safety Information LEXPERT PROFILE L
Cómo obtener tu INFORMACIONES DE SEGURIDAD en la versión
multilingüe.
Siempre puedes descargar la versión multilingüe del Manual de
Instrucciones de Seguridad para este producto ADB en el siguiente
enlace.
www.adbstagelight.com
Rif: FIS00X - Safety Information LEXPERT PROFILE L
FR
RU
Comment obtenir votre CONSIGNES DE SÉCURITÉ dans la version
multilingue.
Vous pouvez toujours télécharger la version multilingue du Manuel
d’Instructions de Sécurité pour ce produit ADB au lien suivant :
www.adbstagelight.com
Rif: FIS00X - Safety Information LEXPERT PROFILE L
Где достать ИНСТРУКЦИЮ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ на
нескольких языках.
Вы всегда можете скачать многоязычную инструкцию по технике
безопасности для данного изделия ADB пo ссылке:
www.adbstagelight.com
Rif: FIS00X - Safety Information LEXPERT PROFILE L
LEXPERT PROFILE L
3
Warning:
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
• Unpack and check carefully there is no transportation damage before using the unit.
• The unit is for indoor use only. Use only in a dry location.
• The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
• Disconnect main power before replacement or servicing.
• Make sure there are no flammable materials close to the unit while operating as it is fire hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always by taking its base.
•
• In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled
people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
• DO NOT touch any wire during operation as high voltage might be causing electric shock.
• To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.
• DO NOT open the unit within five minutes after switching off.
• The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
• Note: Use only the color gel that can resist high temperature. (> 300°C)
Caution:
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require
service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating.
And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also
always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture.
The equipment must be fixed by the professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.
LEXPERT PROFILE L
4
2. TECHNICAL SPECIFICATIONS
• DMX Control: 5 Channel Modes:
Mode 1: 8 bit dimming
Mode 2: 8 bit dimming + Strobe
Mode 3: 16 bit dimming
Mode 4: 16 bit dimming + Strobe
Mode 5: 16 bit dimming + Strobe + Control
• Control Modes: DMX 512, ArtNET, RDM, Web page, Master/Slave and local.
Loosen two screws on two sides of Main Body (MB), rotate the zoom as the arrow and align it with two triangles signs, put the zoom into the MB - Fig. 3
LEXPERT PROFILE L
6
Yellow/Green
Two triangles
signs
Two triangles
signs
S
crew
4
Rotate the zoom as the arrow shown, align it with two triangles sign, and tighten the two screws on two sides of the unit to fix the zoom - Fig. 4
5.POWER
The power requirements are as follows:
Voltage: AC100-240V, 50/60Hz
Power: 345W
The fixture is supplied with a power cable (14 AWG brown and blue cables) installed ready for connection.
5
Power cord colors - Fig. 5
Lock out power to the installation.
Connect the conductors in the power cable to the distribution circuit as follows:
Connect the brown wire to live (one phase).
Connect the blue wire to neutral.
Connect the yellow wire to ground (earth).
Check that all installation is completed and carry out appropriate tests and safety checks before applying power.
LEXPERT PROFILE L
7
6. CONTROL PANEL
6
1. Display: To show the various menus and the selected functions.
2. LED:
MASTER
SLAVE
DMX
3. Dimmer Adjust Knob: Adjust the lightness for the unit
4. Button:
MENU
DOWN
UP
ENTER
5. DMX IN: For DMX512 link, use 5-pin XLR cable to link the unit and the DMX controller;
6. DMX OUT: For DMX512 link, use 5-pin XLR cable to link the next unit and output DMX signal;
7. ETHERNET: Transfers fixture’s information to a main controller
8. Fuse (T 6.3A): To protect the unit from damage of over current;
9. MAINS IN/OUT: PowerCon connection from main power supply or to the next unit;
To select the programming functions
To go backward in the selected functions
To go forward in the selected functions
To confirm the selected functions
OnMaster Mode
OnSlave Mode
OnDMX input present
LEXPERT PROFILE L
8
7. MAIN FUNCTION
To select any functions, press the MENU button until the required function is showing on the display.
Select the function by pressing the ENTER button and the display will blink. Use the DOWN and UP button to change the mode.
Once the required mode has been selected, press the ENTER button to setup to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode. The main functions are shown below:
LEXPERT PROFILE L
9
LEXPERT PROFILE L
10
DMX Address
LinearQuadraticInverse SquareS-curve
To select the DMX Address, press the ENTER button to show DMX ADDRESS on the display. Use the DOWN/UP button to adjust the address from 1
to 512. Once the address has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button
again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Setup
To select Setup press the ENTER button to confirm, use the UP/DOWN button to select DMX Modes, Dimmer Settings, Output Modes, Data Input,
Ethernet Interface, Display Setting or Frequency.
MX Modes
D
To select the DMX Modes, press the ENTER button to show DMX Modes on the display. Use the DOWN/UP button to select the Mode1, Mode2,
ode3, Mode4 or Mode5. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press
M
the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Dimmer Settings
To select the Dimmer Settings, press the ENTER button to show Dimmer Settings on the display. Use the DOWN/UP button to select the Dimmer
Curve or Dimmer Speed. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes pressthe MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Dimmer Curve
To select the Dimmer Curve, press the ENTER button to show Dimmer Curve on the display. Use the DOWN/UP button to select the Quadratic,
Linear, Inv.square or S Curve. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changespress the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
DIMMER CURVES
Curve 1 - Linear:
The increase in light intensity appears to be linear as DMX value is increased.
Curve 2 - Quadratic:
Light intensity control is finer at low levels and coarser at high levels.
Curve 3 - Inverse Square:
Light intensity control is coarser at low levels and finger at high levels.
Curve 4 - (S-curve):
Light intensity control is finger at low levels and high levels and coarser at medium levels.
Dimmer Speed
To select the Dimmer Speed, press the ENTER button to show Dimmer Speed on the display. Use the DOWN/UP button to select the Fast or Smooth.
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one
Output Modes
To select the Output Modes, press the ENTER button to show Output Modes on the display. Use the DOWN/UP button to select the Boost, Regulated,
Silent or Ultra Silent. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the
MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Data Input
To select the Data Input, press the ENTER button to show Data Input on the display. Use the DOWN/UP button to select the Auto, DMX or Art-Net.
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Ethernet interface
To select the Ethernet Interface, press the ENTER button to show Ethernet Interface on the display. Use the DOWN/UP button to select the Network,
Art-net or Repeat on DMX. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changespress the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
LEXPERT PROFILE L
11
Network
o select the Network, press the ENTER button to show Network on the display. Use the DOWN/UP button to select the IP or Mask. Once the mode
T
has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press
the MENU button for one second or wait for one minute to exit the menu mode.
Art-net
To select the Art-net, press the ENTER button to show Art-net on the display. Use the DOWN/UP button to select the Net, Sub Net or Universe. Once
the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold
and press the MENU button for one second or wait for one minute to exit the menu mode.
Repeat on DMX
To select the Repeat on DMX, press the ENTER button to show Repeat on DMX on the display. Use the DOWN/UP button to select the Yes or No.
nce the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
O
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Display Settings
To select the Display Settings press the ENTER button to confirm, use the UP/DOWN button to select Display Inverse, Black Light Auto, Off Luminosity, Contrast orTemperature Unit.
Display Inverse
To select the Display Inverse, press the ENTER button to show Display Inverse on the display. Use the DOWN/UP button to select the Yes or No.
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Black Light Auto
To select the Black Light Auto, press the ENTER button to show Black Light Auto on the display. Use the DOWN/UP button to select the Yes or No.
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Off Luminosity
To select the Off Luminosity, press the ENTER button to show Off Luminosity on the display. Use the DOWN/UP button to adjust Luminosity from 1
to 10. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button
again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Contrast
To select the Contrast, press the ENTER button to show Inverted on the display. Use the DOWN/UP button to adjust Contrast from 1 to 30. Once the
mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and
press the MENU button for one second or wait for one minute to exit the menu mode.
Temperature Unit
To select the Temperature Unit, press the ENTER button to show the Temperature Unit on the display. Use the DOWN/UP button to select the °C or
°F. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any change press the MENU button again.Press and hold the MENU button about one second or wait for one minute to exit the menu mode.
Frequency
To select the Frequency, press the ENTER button to show the Frequency on the display. Use the DOWN/UP button to select the 600Hz, 1200Hz,
1800Hz, 2400Hz, 3000Hz, 3600Hz, 4200Hz, 4800Hz. Once the mode has been selected, press the ENTER button to setup, to go back to the functions
without any change press the MENU button again. Press and hold the MENU button about one second or wait for one minute to exit the menu mode.
Informations
To select the Informations press the ENTER button to confirm, use the UP/DOWN button to select Firmware, Network, Art-net, DMX Value ,Fan
Speed, DMX in Rate, Frequency, I out, Hours or Device ID.
Firmware
To select the Firmware, press the ENTER button to show Firmware on the display and the display will show the version of software of the unit. To go back to
the functions without any changes press the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu
mode.
Network
To select the Network, press the ENTER button to show Network on the display. Use the DOWN/UP button to select the IP , Mask or DHCP on/off.
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Art-net
To select the Art-net, press the ENTER button to show Art-net on the display. Use the DOWN/UP button to select the Net, Sub Net or Universe. Once
the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold
and press the MENU button for one second or wait for one minute to exit the menu mode.
DMX Value
To select the DMX Value, press the ENTER button to show DMX Value on the display. Use the DOWN/UP button to select the Dimmer, Dimmer Fine,
LEXPERT PROFILE L
12
Strobe or Control. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the
MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Fan Speed
To select the Fan Speed, press the ENTER button to show Fan Speed on the display. Use the DOWN/UP button to select the Led Fan or PCB Fan.
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Temperature
To select the Temperature, press the ENTER button to show the Temperature on the display. Use the DOWN/UP button to select the Led or CPU .
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any change press the MENU button again.
Press and hold the MENU button about one second or wait for one minute to exit the menu mode.
DMX in Rate
To select the DMX in Rate, press the ENTER button to show DMX in Rate on the display. Use the DOWN/UP button to select In ms. Once the mode
has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press
the MENU button for one second or wait for one minute to exit the menu mode.
Frequency
To select the Frequency, press the ENTER button to show Frequency on the display. Use the DOWN/UP button to select Freq Selec. Once the mode
has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press
the MENU button for one second or wait for one minute to exit the menu mode.
I out
To select the I out, press the ENTER button to show I out on the display. Use the DOWN/UP button to select the Unit or Led. Once the mode has been
selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press the MENU
button for one second or wait for one minute to exit the menu mode.
Hours
To select the Hours, press the ENTER button to show I out on the display. Use the DOWN/UP button to select the Unit or Leds. Once the mode has
been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press the
MENU button for one second or wait for one minute to exit the menu mode.
Device ID
To select the Device ID, press the ENTER button to show Device ID on the display and the display will show the Device ID of the unit. To go back to the func-
tions without any changes press the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Manual CTRL
To select the Manual CTRL press the ENTER button to confirm, use the UP/DOWN button to select Dimmer, Dimmer Fine or Strobe.
Dimmer
To select the Dimmer, press the ENTER button to show Dimmer on the display. Use the DOWN/UP button to adjust Dimmer from 0 to 255. Once the
mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and
press the MENU button for one second or wait for one minute to exit the menu mode.
Dimmer Fine
To select the Dimmer Fine, press the ENTER button to show Dimmer Fine on the display. Use the DOWN/UP button to adjust Dimmer from 0 to 255.
Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
Strobe
To select the Strobe, press the ENTER button to show Strobe on the display. Use the DOWN/UP button to adjust Dimmer from 0 to 255. Once the
mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and
press the MENU button for one second or wait for one minute to exit the menu mode.
Advanced
To select the Advanced press the ENTER button to confirm, use the UP/DOWN button to select RDM, Data Loss Settings, Slave Mode or Factory
Settings
RDM
To select the RDM, press the ENTER button to show RDM on the display. Use the DOWN/UP button to select the On or Off. Once the mode has been
selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold and press the MENU
button for one second or wait for one minute to exit the menu mode.
Data Loss Settings
To select the Data Loss Settings, press the ENTER button to show Data Loss Settings on the display. Use the DOWN/UP button to select the Black
Out, Last State or Master/Slave. Once the mode has been selected, press the ENTER button to setup, to go back to the functions without any changespress the MENU button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
LEXPERT PROFILE L
13
Slave Mode
CHANNEL
VALUE
FUNCTION
1
DIMMER
0 – 255
Close " Open ˄0% ~ 100% ˅
o select the Slave Mode, press the ENTER button to show Slave Mode on the display. Use the DOWN/UP button to select the Master or Slave. Once
T
the mode has been selected, press the ENTER button to setup, to go back to the functions without any changes press the MENU button again. Hold
and press the MENU button for one second or wait for one minute to exit the menu mode.
Factory Setting
To select the Factory Setting, press the ENTER button to show FACTORY SETTING on the display, use the DOWN/UP button to select No (keep the
present setting) or Yes (the fixture will reset to factory settings and exit menu mode). To go back to the functions without any changes press the MENU
button again. Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
8. HOW TO CONTROL THE UNIT
You can operate the unit in five ways:
1. Universal DMX controller
2. RDM.
3. Master/Slave.
4. Art-Net.
5. Manual.
8.1 DMX Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Functions, press the ENTER button to confirm, use the UP/DOWN button to select DMX Ad-dress, press the ENTER button to confirm, the present address will blink on the display, use the UP/DOWN button to adjust the address from 001 to
512, and press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 7 seconds to exit menu mode.
Please refer to the following diagram to set the DMX address for the first 4 units
Channel Mode
1 Channels
2 Channels
3 Channels
4 Channels
5 Channels
Unit 1
Address
1234
1357
14710
15913
161116
Unit 2
Address
Unit 3
Address
Unit 4
Address
8.2 DMX Configuration
1 Channel Mode
LEXPERT PROFILE L
14
2 Channel Mode
CHANNEL
VALUE
FUNCTION
1
DIMMER
0 – 255
Close " Open ˄0% ~ 100% ˅
2
Strobe
000 -00 9
010 -057
058 -059
060 -108
109 -110
111 -159
160 -161
162 -207
208 -209
210 -253
254 -255
Open
Strobe (variable speed)
Open
Pulse Slow closing fast opening variable speed
Open
Pulse fast closing slow opening variable speed
Open
Random Strobe Slow to Fast
Open
Random Pulse Slow to Fast
Open
CHANNEL
VALUE
FUNCTION
1
DIMMER
0 – 255
Close " Open ˄0% ~ 100% ˅
2
0 – 255
Dimmer Fine
0% ~ 100%
3 Channel Mode
LEXPERT PROFILE L
15
4 Channel Mode
CHANNEL
VALUE
FUNCTION
1
DIMMER
0
– 255
C
lose " Open ˄0% ~ 100% ˅
2
0 – 255
Dimmer Fine
0% ~ 100%
3
Strobe
000 - 009
010-057
058-059
060-108
109 -110
111 -159
160 -161
162 -207
208 -209
210 -253
254 -255
Open
Strobe (variable speed)
Open
Pulse Slow closing fast opening variable speed
Open
Pulse fast closing slow opening variable speed
Open
Random Strobe Slow to Fast
Open
Random Pulse Slow to Fast
Open
LEXPERT PROFILE L
16
5 Channel Mode
2
0 – 255
Dimmer Fine
0% ~ 100%
3
Strobe
000 - 009
010-057
058-059
060-108
109 -110
111 -159
160 -161
162 -207
208 -209
210 -253
254 -255
Open
Strobe (variable speed)
Open
Pulse Slow closing fast opening variable speed
Open
Pulse fast closing slow opening variable speed
Open
Random Strobe Slow to Fast
Open
Random Pulse Slow to Fast
Open
4
Control
000-009
010-045
046-080
081-115
116 -150
151 -235
236 -240
241 -245
246 -250
251 -255
No function
RDM ON
RDM OFF
Dimmer Speed smooth
Dimmer Speed auto
Reserved
Curve Quadratic
Curve Linear
Curve Inv Square Law
Curve S
CHANNEL
VALUE
FUNCTION
1
DIMMER
0 – 255
Close " Open ˄0% ~ 100% ˅
LEXPERT PROFILE L
17
8.3 DMX Connection
1
2
4
5
3
1
2
4
5
3
DMX OUTPUTDMX INPUT
COMMON
DMX -
DMX +
Not Used
Not Used
5
4
2
1
3
DMX Controller
DMX OUT
7
1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 5pin XLR-plug and plug it in the DMX-output of the last unit.
2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable cannot be branched
or split to a “Y” cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort
the signal and shut down the system.
3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 0-511 (usually 0 & 1 are equal
to 1).
5. The end of the DMX 512 system should be terminated to reduce signal errors.
6. 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used
LEXPERT PROFILE L
18
9. TROUBLESHOOTING
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors and cables to see if link properly.
2. If the DMX LED is on but no response check the address settings and DMX polarity.
3. If you have intermittent DMX signal problems check the cables on connectors.
4. Try to another DMX controller.
5. Check if the DMX cables run near or run alongside high voltage cables that may cause interference to DMX circuits.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave mode signal.
2. Wrong DMX address in the unit. Set the correct address.
. No response to the sound
D
1. Make sure the unit is set into the correct mode.
2. Check the microphone to see if it is good by tapping it.
3. Make sure the fixture is not set into Blackout mode.
10. FIXTURE CLEANING
The cleaning of external must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture
operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics.
• Clean with soft cloth using normal glass cleaning fluid.
• Always dry the parts carefully.
• Clean the external optics at least every 30 days.