OSNA LG 100, LG 200, LG 400, LG 500, LG 750 Original Operating Manual

Ver.16-08
Original Operating Manual
LG Piston Pump
OSNA-Pumpen GmbH
Brückenstrasse 3
49090 Osnabrück, Germany
Phone: +49 541 1211 - 0
Internet: http://www.osna.de
E-mail: info@osna.de
LG Piston Pump 1
Contents
1 GENERAL...................................................................................................................................5
1.1 About this operating manual..................................................................................................5
1.2 Target groups .......................................................................................................................5
1.3 Other valid documents ..........................................................................................................5
1.4 Warning notices and symbols................................................................................................6
1.5 Copyright/changes................................................................................................................6
2 SAFETY ......................................................................................................................................7
2.1 Correct and proper use .........................................................................................................7
2.2 General safety instructions....................................................................................................8
2.2.1 Product safety................................................................................................................8
2.2.2 Duties of the system owner ............................................................................................8
2.2.3 Duties of personnel ........................................................................................................9
2.3 Dangers of non-observance of the safety instructions..........................................................10
2.4 Unauthorized conversion and production of spare parts.......................................................10
2.5 Unauthorized modes of operation........................................................................................10
2.6 Special hazards ..................................................................................................................10
2.6.1 Explosion area.............................................................................................................10
2.6.2 Hazardous pumping media...........................................................................................10
2.6.3 Noise emissions...........................................................................................................10
3 LAYOUT AND FUNCTION ........................................................................................................11
3.1 Labeling..............................................................................................................................11
3.2 Scope of delivery, type LG piston pump ..............................................................................11
4 TRANSPORT AND INTERMEDIATE STORAGE.......................................................................13
4.1 Transport ............................................................................................................................13
4.1.1 Unpacking and checking the delivery condition.............................................................13
4.1.2 Lifting...........................................................................................................................13
4.2 Storage...............................................................................................................................13
4.3 Intermediate storage...........................................................................................................14
4.4 Disposal..............................................................................................................................14
5 LAYOUT AND MODE OF OPERATION ....................................................................................15
5.1 Mode of operation...............................................................................................................15
5.2 Functional and operating elements......................................................................................15
5.3 Layout of the piston pump with pressurized container..........................................................16
5.4 Technical data ....................................................................................................................17
6 ASSEMBLY AND INSTALLATION............................................................................................18
6.1 Preparing for installation......................................................................................................18
2 LG Piston Pump
6.1.1 Checking the surrounding conditions............................................................................18
6.1.2 Preparing the installation location.................................................................................18
6.1.3 Preparing the base surface and foundations.................................................................18
6.2 Installation ..........................................................................................................................18
6.2.1 Installing the pump.......................................................................................................18
6.2.2 Electrical connection ....................................................................................................19
6.2.3 Water connection.........................................................................................................19
6.2.4 Assembling the piston pump with additional pressurized container ...............................20
6.3 Installation ..........................................................................................................................21
6.3.1 Installing the V-belt.......................................................................................................21
6.3.2 Belt guard ....................................................................................................................22
6.3.3 Installing the snifter valve .............................................................................................24
7 COMMISSIONING/ DECOMMISSIONING ................................................................................25
7.1 Preparing for commissioning...............................................................................................25
7.1.1 Determining the pump configuration.............................................................................25
7.1.2 Filling the drive casing with oil ......................................................................................25
7.2 Commissioning ...................................................................................................................26
7.2.1 Filling the pump............................................................................................................26
7.2.2 Checking direction of rotation .......................................................................................27
7.2.3 Starting the piston pump ..............................................................................................27
7.3 Decommissioning................................................................................................................29
7.4 Recommissioning................................................................................................................30
8 MAINTENANCE AND REPAIR..................................................................................................32
8.1 Maintenance.......................................................................................................................32
8.1.1 Oil level........................................................................................................................32
8.1.2 V-belt...........................................................................................................................33
8.1.3 Adding air ....................................................................................................................33
8.1.4 Stuffing box..................................................................................................................34
8.2 Maintenance service ...........................................................................................................34
8.2.1 Oil change....................................................................................................................35
8.2.2 Sending the pump to the manufacturer.........................................................................35
8.3 Safety valve........................................................................................................................35
9 FAULTS AND TROUBLESHOOTING........................................................................................37
10 APPENDIX.............................................................................................................................39
10.1 Service, spare parts, accessories ....................................................................................39
10.2 Individual parts of the LG piston pump.............................................................................40
10.3 Motor assembly...............................................................................................................44
10.4 Declaration of Conformity as per EC Directive 2006/42/EC, Annex IIA .............................46
10.5 Clearance Certificate.......................................................................................................47
LG Piston Pump 3
List of Tables
Table 1: Target groups and their tasks ................................................................................................5
Table 2: Other valid documents and their purposes............................................................................5
Table 3: Warning notices and consequences of non-observance.........................................................6
Table 4: Symbols and their meanings..................................................................................................6
Table 5: Starting torques...................................................................................................................12
Table 6: Technical data.....................................................................................................................17
Table 7: Measures in the event of operational interruption................................................................29
Table 8: Measures depending on the behavior of the pumping medium.............................................29
Table 9: Measures following longer shut down time...........................................................................31
Table 10: Measures for return ...........................................................................................................35
Table 11: Selection of SIOS valves ...................................................................................................36
Table 12: Fault causes......................................................................................................................38
Table 13: Parts list for the LG 100-400 piston pump ..........................................................................41
Table 14: Parts list for the LG 500-750 piston pump ..........................................................................43
Table 15: Motor assembly parts list for LG 100-400...........................................................................44
Table 16: Motor assembly parts list for LG 500-750...........................................................................45
4 LG Piston Pump
List of Images
Figure 1: Model code ........................................................................................................................11
Figure 2: Scope of delivery for type LG..............................................................................................11
Figure 3: Functional elements 1 ........................................................................................................15
Figure 4: Functional elements 2 ........................................................................................................15
Figure 5: Layout with pressurized container.......................................................................................16
Figure 6: Dimensions in front view.....................................................................................................17
Figure 7: Dimensions in side view .....................................................................................................17
Figure 8: Installation area side view...................................................................................................19
Figure 9: Installation area front view..................................................................................................19
Figure 10: Motor protection switch.....................................................................................................19
Figure 11: Water connection .............................................................................................................20
Figure 12: Assembly with pressurized container................................................................................20
Figure 13: Assembly with pressurized container................................................................................21
Figure 14: Tensioning the V-belt........................................................................................................21
Figure 15: Belt guard for LG 100 - 400 ..............................................................................................22
Figure 16: Assembling the belt guard for LG 500 and 750 ................................................................23
Figure 17: Removing the belt guard for LG 500 and 750....................................................................24
Figure 18: Snifter valve .....................................................................................................................24
Figure 19: Drive casing.....................................................................................................................25
Figure 20: Water side........................................................................................................................26
Figure 21: Starting the piston pump...................................................................................................28
Figure 22: Draining the pump............................................................................................................30
Figure 23: Oil level............................................................................................................................32
Figure 24: V-belt guard .....................................................................................................................33
Figure 25: Adding air.........................................................................................................................33
Figure 26: Stuffing box......................................................................................................................34
Figure 27: Oil change........................................................................................................................35
Figure 28: Safety valve .....................................................................................................................36
Figure 29: Explosion diagram of the LG 100-400 piston pump...........................................................40
Figure 30: Explosion diagram of the LG 500-750 piston pump...........................................................42
Figure 31: Explosion diagram of the LG 100-400 motor assembly .....................................................44
Figure 32: Explosion diagram of the LG 500-750...............................................................................45
1 General
LG Piston Pump 5
1 General
1.1 About this operating manual
This operating manual contains important in­structions that must be observed during instal­lation, operation and maintenance. For this reason, ensure that it is read by specialist per­sonnel and the responsible operator/owner prior to assembly and commissioning. The manual must be available at all times at the lo­cation where the system is used.
Please observe the safety instructions de­scribed in this operating manual, along with the relevant national accident prevention regula­tions and any internal work, operational and safety specifications of the operator. We as­sume no liability for damages and operational interruptions resulting from non-observance of this operating manual.
WARNING
Pay particular attention to section 2 "Safety in­structions" during commissioning and all maintenance work.
Section 2 also provides an explanation of the symbols used in this manual. Knowledge of this operating manual is essential to preventing errors and ensuring safe and uninterrupted operation.
The operating specification does not take local safety regulations into account. The owner bears full responsibility for compliance with these, including on the part of the assembly personnel used.
This operating manual:
is part of the pump
is valid for all type series mentioned
describes safe and proper use in all
phases of operation
1.2 Target groups
Target group Task
System owner
Ensure that this manual is available at the location where the system is used, including for later reference.
Ensure that personnel read and observe this operat­ing manual and the other val­id documents, in particular the safety and warning infor­mation.
Observe additional sys­tem-related regulations and specifications.
Specialist person­nel, assembly staff
Read, observe and follow this operating manual and the other valid documents, in particular the safety and warning information.
Table 1: Target groups and their tasks
1.3 Other valid documents
Document Purpose
Installation diagram Installation dimen-
sions, connection di­mensions, etc.
Spare parts list Ordering spare parts
Clearance certificate Returning the pump
Declaration of conformity Conformity with
standards, content of the declaration of con­formity
Table 2: Other valid documents
and their purposes
1 General
6 LG Piston Pump
1.4 Warning notices and symbols
Warning notice Hazard
level
Consequenc­es of non­observance
DANGER
Immediate hazard
Death, severe physical injury
WARNING
Potential hazard
Death, severe physical injury
CAUTION
Potentially dangerous situation
Minor physical injury
NOTICE
Potentially dangerous situation
Material dam­age
Table 3: Warning notices and consequences of non-
observance
Symbol Meaning
Safety sign
Follow all instructions identified with safety signs in order to avoid death or injuries.
Instruction
1. , 2. , Instruction with multiple steps
Condition
Reference
Information, note
Table 4: Symbols and their meanings
1.5 Copyright/changes
The intellectual property and all copyrights re­lated to this technical documentation remain exclusively with OSNA-Pumpen GmbH. All rights reserved, in particular the right to repro­duction and distribution of this documentation, including translations thereof.
No part of this documentation may be repro­duced in any form (print, photocopy, microfilm or any others process), stored, processed, re­produced or distributed using electronic sys­tems without written permission.
Editorial changes reserved exclusively by OSNA-Pumpen GmbH.
Any violation is punishable and subject to compensation.
OSNA GmbH reserves the right to change the contents of this documentation without notice.
2 Safety
LG Piston Pump 7
2 Safety
The manufacturer shall not bear any liability for damages caused as a result of non­observance of this documentation.
2.1 Correct and proper use
Only use this pump for the purposes of conveying the agreed pumping media.
Comply with operating limits.
The water may not contain any abra-
sive or long-fibered components that may damage the pump materials. Consult the manufacturer if using other media.
Ensure that the pump is only commis­sioned with pumping medium and is not operated without it.
Open the suction-side fitting, and do not use it to control the flow rate.
Never operate the pump when the ar­mature on the delivery side is closed.
To avoid damaging the motor, observe the permitted number of times per hour that the motor can be switched on ( Manufacturer information).
Any other use must be agreed with the manufacturer.
The temperature of the pumping me­dium must not exceed 40 °C.
Avoiding obvious misuse (examples)
Observe the operating limits of the pump for temperature, pressure, flow rate and speed.
The main areas of use are:
Water supply to single-family and mul­tiple-family homes
Water supply to businesses and agri­culture
Sprinkling and irrigation of gardens and other usable areas
The pump is self-priming after being filled once with water.
Do not operate the pump without water. Dry running can lead to damage to the pump.
Ensure that the foot valve is in the water at all times.
WARNING
Any use that goes beyond the purposes described above shall be considered im­proper use. OSNA shall bear no liability for any resulting damages. The owner bears full risk for improper use.
2 Safety
8 LG Piston Pump
2.2 General safety instructions
Please observe the following specifications before performing any activities.
2.2.1 Product safety
This pump is constructed according to the lat­est state of the art and accepted safety rules. Nevertheless, risks to life and limb for the user or third parties are still possible when using the pump, as are impairments to the pump and other material assets.
Only use the pump in a technically perfect state and for the intended pur­pose. Ensure compliance with this op­erating manual and be aware of the hazards and safety issues during op­eration.
Keep this operating manual and all other valid documents in a complete and legible state, and store in a loca­tion that is accessible at all times to personnel.
Do not permit any activity that endan­gers personnel or uninvolved third par­ties.
In the event of a safety-relevant fault, stop the pump immediately and have the fault rectified by responsible per­sonnel.
In addition to this documentation, en­sure compliance with the statutory or other regulations for safety and acci­dent prevention, as well as the rele­vant standards and specifications of the respective country.
Do not remove any technical stickers.
2.2.2 Duties of the system owner
Safety-conscious work
Observe the safety specifications detailed in this operating manual, along with the occupa­tional safety regulations and all additional in­ternal safety regulations.
Only use the pump in a technically perfect state and for the intended pur­pose. Ensure compliance with this op­erating manual and be aware of the hazards and safety issues during op­eration.
Ensure compliance and monitoring:
- correct and proper use
- statutory or other safety and acci-
dent prevention regulations
- safety specifications for handling
hazardous substances
Provide personal protective equip­ment.
Do not remove contact protection dur­ing operation.
Prevent any dangers from electrical energy (for details, please refer to the specifications of the VDE and the local energy supplier).
Switch off the motor during all assem­bly and maintenance works, and se­cure against reactivation.
Only work on the system when the pump is at a standstill.
2 Safety
LG Piston Pump 9
Personnel qualification
The owner of the system must ensure that the personnel tasked with working on the pump have read and understood this operating man­ual and all other valid documents before be­ginning work, in particular information on safe­ty, maintenance and repair.
Work of any kind on the machine may only be performed when it has been completely de­commissioned. Reinstall and reactivate all safety mechanisms after work.
Before restarting the machine, ensure that all necessary commissioning steps have been completed (7.2 Commissioning, pg 26).
Determine responsibilities, tasks and monitoring for personnel.
Only allow work of any kind to be per­formed by specialist technical person­nel:
- assembly, maintenance and repair
work
- work on the electrical systems
Only allow personnel undergoing train­ing to perform work on the pump under the supervision of specialist technical personnel.
Safety mechanisms
Provide the following safety mecha­nisms and ensure that they function correctly:
- for moving components: contact
protection for the pump, installed by the customer
- for potential electrostatic charges:
provide appropriate earthing
Guarantee
Please consult the manufacturer be­fore carrying out any conversions, re­pairs or changes during the guarantee period.
Only use original parts or parts ap­proved by the manufacturer.
2.2.3 Duties of personnel
Observe the information on the pump and ensure it is legible (e.g. direction of rotation arrow, fluid connection indi­cators).
Do not remove the contact protection for moving parts during operation.
Use personal protective equipment if necessary.
Only work on the system when the pump is at a standstill.
Switch off the motor during all assem­bly and maintenance works, and se­cure against reactivation.
Reinstall the safety mechanisms after working on the pump according to specifications.
2 Safety
10 LG Piston Pump
2.3 Dangers of non-observance of the safety instructions
Non-observance of the safety instruc­tions can lead to hazards to personnel, the machine and the environment.
Non-observance of the safety instruc­tions can also lead to the loss of any damage claims.
In particular, non-observance can lead to the following dangers:
- failure of important system func-
tions
- electrical and mechanical hazards
to personnel
2.4 Unauthorized conversion and production of spare parts
Conversions or changes to the machine are only permitted following consultation with the manufacturer. Original spare parts and acces­sories authorized by the manufacturer help en­sure safety. The manufacturer bears no liability for the consequences of the use of other parts.
2.5 Unauthorized modes of opera­tion
The operational safety of the machine is only guaranteed when it is used for the intended purpose according to the operating manual (
2.1 Correct and proper use, pg 7). Never exceed the limit values indicated in the technical data
.
2.6 Special hazards
2.6.1 Explosion area
Do not use the pump in areas where there is a risk of explosion.
2.6.2 Hazardous pumping media
Observe the safety regulations for handling hazardous substances (e.g. toxic, hazardous to health).
Use personal protective equipment when performing work on the pump.
2.6.3 Noise emissions
The maximum continuous sound pressure lev­el for a correctly installed and commissioned LG piston pump is 70 dB(A).
3 Layout and function
LG Piston Pump 11
3 Layout and function
3.1 Labeling
This operating manual applies to pumps of the LG 100 to LG 750 series.
Model code:
Figure 1: Model code
3.2 Scope of delivery, type LG pis­ton pump
The customer can order the pump:
in a preassembled state, i.e. delivery without motor, accessories enclosed unassembled. The motor is installed by the customer.
in a fully assembled state, i.e the pump is fitted with motor ex-works.
The scope of delivery corresponds to the scope indicated in the order. Please check that the delivery is complete upon receipt. Notify the delivery company of any transport damage immediately. Please also refer to our condi­tions of sale and delivery. If using other motor brands, please ensure that the motors have the following drive torques as a multiple of the nominal torque.
Figure 2: Scope of delivery for type LG
Key:
1 Pump
2 Accessories (includes items 3 to 9, fully as-
sembled in complete version)
3 V-belt
4 Belt guard with holder and clamping set
5 V-role pulley key for motor shaft with lock
screw
6 Motor with motor fastening set
7 Snifter valve
8 Oil dipstick
9 Assembly and operating manual
LG 100
Size
OSNA - piston pump with gear unit
3 Layout and function
12 LG Piston Pump
Motor power
Starting torque ratio
[kW]
Ms/Mn
Mn [Nm]
0.37 1.9 2.5
0.55 1.7 3.7
0.75 1.6 5.0
1.1 2.0 7.3
1.5 2.3 9.9
2.2 2.6 14.6
3.0 2.8 20.0
Table 5: Starting torques
Ms= Starting torque
M
n
= Nominal torque
kW = Kilowatt
Nm = Newton meter
List applies only to three-phase motors.
4 Transport and intermediate storage
LG Piston Pump 13
4 Transport and intermediate storage
4.1 Transport
Weight information ( Other valid docu­ments)
NOTICE
Transport the pumps carefully and secure them to prevent damage.
Avoid applying pressure to the pump-side
V-role pulley key.
4.1.1 Unpacking and checking the de­livery condition
1. Check that the delivery is complete upon receipt.
2. Unpack the pump/unit upon delivery and check for transport damage.
3. Notify the delivery company of any transport damage immediately.
4. Dispose of the packaging material in line with the applicable local regula­tions.
4.1.2 Lifting
DANGER
Risk of death or crushed limbs from falling transported goods!
Choose lifting equipment that is suitable for the total weight to be transported.
Do not stand under suspended loads.
4.2 Storage
NOTICE
Material damage due to incorrect storage!
Ensure that the pump is correctly stored.
1. Close all openings with blank flanges, blind plugs or plastic covers.
2. Ensure that the storage area meets the following conditions:
dry
free of frost
free of vibrations
3. Move the piston rod once per month.
4 Transport and intermediate storage
14 LG Piston Pump
NOTICE
Damage to bearings due to high water pressure or splashing water!
Do not use water jets or steam jet cleaners
to clean the bearing areas.
NOTICE
Damage to seals due to incorrect cleaning agent!
Ensure that the cleaning agent does not
corrode the seals.
1. Choose the cleaning agent according to the area of use.
2. Dispose of preservatives in line with the applicable local regulations.
3. When storing for longer than 6 months:
Check all elastomers (round seals, shaft seal rings, gaskets and gland packing) for elasticity, and replace if necessary.
4.3 Intermediate storage
Ensure during intermediate storage that the pump is not exposed to any weather conditions for a long period of time. If the pump is de­commissioned for a longer period of time (ap­proximately 2 to 3 months), ensure that it is ful­ly drained. (7.3 Decommissioning, pg 29)
4.4 Disposal
Plastic parts may be contaminated by toxic or radioactive pumping media. If this is the case, cleaning is not sufficient.
WARNING
Risk of poisoning and environmental dam­age from pumping medium!
Use personal protective equipment when
performing work on the pump.
Before disposing of the pump:
Collect the oil and dispose of it in line with the applicable local regu­lations.
Neutralize any pumping medium residues in the pump.
Dispose of the pump in line with the appli-
cable local regulations.
Loading...
+ 36 hidden pages