OSEE RMD7023 User Manual

RMD7023
USER MANUAL
MODEL: RMD7023 LCD MONITOR Version: V030000 Release Date: 2010-2-26
COMPANY NAME
Beijing Osee Digital Technology Ltd.
CONTACT INFORMATION
Address: Room 702, Tower D, Jinyujiahua Building, No.9, 3rd Shangdi Street, Haidian District, Beijing, China Post code:100085 Tel: 8610-62968823 Fax: 8610-62977165 Http://www.osee-dig.com E-mail:sales@osee-dig.com
About The USER MANUAL
The user manual applies to the following device types:
RMD7023-HSC RMD7023-SC RMD7023-V
The images of RMD7023-HSC are adopted in the following descriptions. Any of the different specifications between the device types are elaborated. Before reading the manual, please confirm the device type.
Contents
Chapter 1 Product Overview .............................................................................................. 1
Chapter 2 Safety Precaution for Use .................................................................................. 2
Chapter 3 Unpacking and Installation ............................................................................... 3
Chapter 4 Using the RMD7023 ........................................................................................... 4
4.1 Status Display of the Screen .......................................................................................................... 4
4.2 Front Panel Controls ...................................................................................................................... 5
4.3 Quick Button Descriptions ............................................................................................................ 7
4.3.1 ENTER BUTTON ............................................................................................................ 7
4.3.2 USER1~ USER3 BUTTON .............................................................................................. 7
4.3.3 MENU BUTTON .............................................................................................................. 9
4.4 Rear Panel ....................................................................................................................................... 9
Chapter 5 Main Menu Structure ....................................................................................... 11
5.1 STATUS Sub-menu .................................................................................................................. 11
5.2 VIDEO Sub-menu .................................................................................................................... 12
5.3 AUDIO Sub-menu .................................................................................................................... 12
5.4 MARKER Sub-menu ............................................................................................................... 14
5.5 OSD Sub-menu ......................................................................................................................... 15
5.6 USER CONTROL Sub-menu .................................................................................................. 19
5.7 USER CONFIG Sub-menu ...................................................................................................... 20
Chapter 6 Technical Specifications .................................................................................. 20
Chapter 7 Warranty for LCD Monitor ............................................................................ 23
RMD7023 LCD MONITOR User Manual
1
Chapter 1 Product Overview
The 3U rack mounted RMD7023 represents ne w trend in LCD monitor for broadcast and professional video applications. It has 800X480 high resolution, anti-glare TFT screens with full digital signal processing. HD-SDI, SD-SDI and analog composite video standards are accepted of this model. All video formats are scaled to fit on screen in the highest quality using full digital processing, precision scaling and Gamma correction to produce the best images available.
The monitor comes with many in monitor display features including WFM, Vectorscope as well as RS485.
Features
Auto- Sensing for HD/SD-SDI, Composite signal Embedded Audio Support4 or 8 Channels Audio Meter (VU & PPM) H/V Delay, Under Scan, Safe&Area Marker, As pect Ratio, Blue Only , Tally 1 Pair Audio Monitoring via Headphone Jack. Built-in speaker. Support COLOR temperature correction. Support Dynamic UMD, and TSL and IMAGE VIDEO protocols. RS485 connector. Waveform and Vectorscope display for SDI signal Support OSD TALLY (SPLIT TALLY); Support LED TALLY. Support SD ASPECT . When the input is CVBS or SD-SDI, it supports 16:9 and 4:3 display. An interface is displayed when USER menu is under operation. Support FPGA and MCU upgrade via RS485.
Product Number Description
RMD7023-HSC Two monitors: each monitor includes two video inputs (support HD-SDI /
SD-SDI / CVBS)four external audio input connectors. One RS485 input (RJ45), One RS485 output (RJ45).
RMD7023-SC Two monitors: each monitor includes two video inputs (support SD-SDI /
CVBS) four external audio input connectors. One RS485 input (RJ45), One RS485 output (RJ45).
RMD7023-V Two monitors: each monitor includes two video inputs (support CVBS) four
external audio input connectors. One RS485 input (RJ45), One RS485 output (RJ45).
RMD7023 LCD MONITOR User Manual
2
Chapter 2 Safety Precaution for Use
Read and keep these instructions. Heed all warnings. Follow all instructions.
About the Position
1. Do not block any ventilation openings.
2. Do not use this unit near water.
3. Do not expose the unit to rain or moisture.
4. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that product heat.
5. A nameplate indicating operating voltage, etc., is located on the rear panel. Install only in
accordance with the instructions in the section entitled, “Unpacking and Installation” on page 3.
6. The socket-outlet shall be installed near the equipment and shall be easily accessible.
About the Power-supply Cord
7. Do not defeat the safety purpose of the polarized or grounding-type plug.
8. Do not damage the power cord, place the heavy objects on the power cord, stretch the power
cord, or bend the power cord.
9. Protect the power cord from being walked on or pinched, particularly at plugs, convenience
receptacles, and the point where they exit from the unit.
10. If the power cord is damaged, turn off the power immediately. It is dangerous to use the unit
with a damaged power cord. It may cause fire or electric shock.
11. Unplug this apparatus during lighting storms or when unused for long periods of time.
12. Disconnect the power cord from the AC outlet by grasping the plug, not by pulling the cord.
13. Should any soli d object or liquid fall into the cabinet, unplug t he unit and have it checked by
qualified personnel before operating it any further.
Monitor
14. Do not beat with a hard object or scratch the LCD display.
15. Do not make the freeze picture displaying on the screen time too long, otherwise, it will leave
the afterimage on the screen.
16. Install in accordance with the manufacturer’s instructions
17. If the brightness is adjusted to the minimum, then it might be hard to see the display screen.
18. Refer all servicing to qualified service personnel. Servicing will be required under all of the
following conditions:
The unit has been exposed to rain or moisture. Liquid had been spilled or objects have fallen onto the unit. The unit has been damaged in any way, such as when the power-supply cord or plug is
damaged.
The unit does not operate normally.
19. Clean only with dry cloth.
20. Specifications are subject to change without notice.
RMD7023 LCD MONITOR User Manual
3
Chapter 3 Unpacking and Installation
1. Unpack the RMD7023 Monitor and inspect for any apparent physical damage that may have occurred in transit. We recommend you reta in the shipping carton for future use. If there be any damage, immediately contact OSEE DIGITAL TECHNOLOGY LTD at +86-010-62968823.
2. After inspection, install in your desired location of a standard EIA 19-inch equipment rack. Adequate ventilation is required when installed to prevent possible damage to the RMD7023 internal components.
3. Connect required cables for signal input and output. Please note that power must be applied to the RMD7023 for all outputs to be activated. For BNC connections use 75 rated connectors.
4. Connect A.C. Mains power using the included power cord. Please ensure an Earth ground present to ensure proper operation of the unit. Fasten the power protect accessory.
5. As a final step turn on each screen of the RMD7023 by depressing the power switch located on the front of the unit.
Supplied Accessories:
1.Monitor 1
2.12 V DC power supply 1
3.User Manual 1
4.Warranty Card 1
RMD7023 LCD MONITOR User Manual
4
Chapter 4 Using the RMD7023
4.1 Status Display of the Screen
1. LED Tally Light: This tri-color (red/green/amber) light is controlled through a DB9
connector on the rear panel. For more information about the DB9 connector, refer to “Rear Panel” on Chapter 4.4.
2. Input Signal Format: It displays the input signal format and can be set in the MAIN
Menu.
3. Safe Areas: Multiple safe areas are configurable in the MAIN Menu.
4. Audio Meters: Levels for the audio. For RMD7023-SC and RMD7023-V, only two
meters on the left side.
5. UMD: The MAIN Menu provides settings to customize the UMD (In-Monitor Display)
text area to show a line of characters, numbers, and/or some symbols.
6. Speakers: Audio may be selected for monitoring through the left and right speakers.
7. Time Code: The de-embedded time code from the HD/SD-SDI source displays in the
top right corner.
8. Waveform and Vectorscope: The signal waveform and vectorscope are configurable
in the MAIN Menu.
Referring to the circumstance of no sync ( power on):
1.
Will indicate on the top left hand of screen: IN A: NO SYNC
2. On the bottom of screen will UMD and METER be shown, but the display of
UMD and METER is subject to the current main menu setting. When in the main menu UMD DISP is set to ON and, no video input, UMD will display; when it is
Audio Meters
UMD
Input Signal format
Time Code
Safe Marker
Waveform or Vectorscope
Speakers
LED Tally Light
OSD Tally
RMD7023 LCD MONITOR User Manual
5
set OFF, UMD won’t be displayed. The same applies to the display of METER.
3. The main menu can still be displayed, but the value of parameter relating to image
is not adjustable; and the value of parameter relating to the display effect can be adjustable.
4.2 Front Panel Controls
1: Power On/Off Switch
When the indicator in the power switch is in green, it indicates that power is on. When the indicator is flashing, it indicates standby.
2: INA/B
Press to select one input signal from two input channels.
3: SCAN
Press to display the 100% image (UNDER SCAN) and 95% (NORMAL) image.
4/5/6: USER1~ USER3
USER1~ USER3” serve as the quick-button; its function can be assigned in the main MENU.
For more information, please refer to “Chapter 4.3.2”)
7: MENU
Press to display the main menu. For more information, please refer to “Chapter 4.3.3” and Chapter5
8/9: Two functions
Press “MENU” button to choose the function you need.
When the “MENU” is not in use, the button of 8/9 can achieve the following functions:
Loading...
+ 18 hidden pages