Orpak Systems 800960000 User Manual

Universal Kit
nNR universal kit suits any spout diameter between 22mm and 32mm as it includes 4 grip kits. Choose your grip kit according to the table below:
Nozzle Model Grip Kit** Set Screws*
Husky 1A 30 6
Husky X 27 6
OPW 11 A/B Leaded 30 6
OPW 11 A/B Unleaded 27 6
OPW Avance HS/VR 32 6
OPW DEF 27 6
Tatsuno Leaded 30 6
Tatsuno Unleaded 27 6
ZVA 25 32 6
ZVA DEF 24 8
ZVA Slim Line 30 6
ZVA S.L. 2-GR 30 6
*Use 10mm set screws when spout diameter is 22mm or below.
** The 32mm grip kit includes only a two-pieces top lid instead of two lids.
Watch nNR Installation Tutorial
Specifications
Parameter Value
Supply Voltage 3.6 internal battery pack P/N 812560010
Power Consumption Active Mode: 160mA Standby Mode 20 μ A
Operating Temperature - 40°to +60° C
Storage Temperature - 40°to +85° C
IP Rating IP 67
Dimensions (HxWxD) 41x84x60.5mm
Weight 132g
Hazardous Area
Zone 1 Ex plos iv e at mos phere ( Ex) ia (i ntr ins ic s afety) prot ecti on l evel Group IIC type produc t TemperatureClass:T6 Rated Tem per atur es:- 40°< Tam b< + 60° C
The FCC Wants You to Know: This equipment has been tested and found to comply with the limits for a Class A & B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : a) Reorient or relocate the receiving antenna. b) Increase the separation between the equipment and receiver. c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. d) Consult the dealer or an experienced radio/TV technician.
FCC Compliance Statement Warning
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired operation. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
FUELING YOUR BUSINESS
FOR SUCCESS
nano Nozzle Reader
Assembly Guide
P/N 817460005
Installation Kit
9
4
7
8
6
3
5
2
3
1
1
3
3mm
5
7
2mm
# Part Name Part Number
1 Set Screws 815221300 (6) 815221380 (8) 815221310 (10)
2 Spout Adaptor 814360500
3 Lids 814360424 (24) 814160427 (27) 814160430 (30) 814360700 (32)
4 Rubber Filler 814160024 (24) 814160027 (27) 814160030 (30) 814160032 (32)
5 M4 Screws 815213424
6 nNR Assembly 819260000 (nNR)/819260100(nNR + Switch)
7 M3 Screws 815260300
8 Front Cover 814360200
9 M3x6 Screws 815260200
Required Tools
3mm Allen head ratchet (not ball ended)
2mm standard Allen key (not ball ended)
Loctite 222/ Holdtite T43 glue
Qty.
4
1
2
1
4
1
4
1
2
Slide the adaptor over the spout. Place it as close as possible to the nozzle body
2
Choose the proper grip kit for the nozzle (see rear table). Place a lid, the rubber filler and then the other lid
Installation Notes
Secure the gip kit with the M4 screws. Tighten them in stages and in a diagonal sequence. Use a 3mm head ratchet
4
2mm
Apply glue and place the set screws in the adaptor corners. Use a 2mm Allen key
Unit should be serviced only by authorized service personnel.
Slide the nNR assembly over the spout
6
2mm
Secure the nNR to the adaptor with the M3 screws. Use a 2mm Allen key
Opening of the unit by Service Personnel must not be done at the location of installation.
Place the nNR front cover on top of the assembly. Secure with the M3 screws. Use a 2mm Allen key
8
Program the unit
When replacing the battery, use only P/N 812560010.