Before designing and during the production, the safety of operators and products all have been
considered. Please following this users instructions strictly to operate or install the machine in
case of personal injury or accident occur.
(1)The installation of the inverter should be done by professionals or under the assistance of the local
dealer. (2)Verify whether the input DC voltage range meets the requirements ±15% and the correctness of
voltage polarity. (3)Confirm the grade of load device voltage ,power should not be more than rated output power of
the inverter
(4)Do not flow any liquid inside the inverter, or with a damp cloth to wipe the machine casing. Can
not be directly Contact the inverter input and output terminals when the machine is running,
especially with wet hands, otherwise electric shock injury will occur.
(5)If you need to change the working environment under the normal working state, do not change its
connection, your operated should be assistance and confirmation by the professionals or supplier.
(6)The operating environment of inverter should be well-ventilated, temperature range -20-45
degrees, keep away from the ignition sources spot and direct sunlight, Can not run in the
condensation, dust environment. During the operating, the heat is normal phenomenon, should
maintain the ventilation, clean installation environment, in particular, can not block the ventilation
holes.
(7)Minors can not use this product.
(8)Confirm weather the inverter can be connected with the earth wire,Live line and Zero line can not
be reversed, the diameter shall comply with the conditions of safe use, for the cable, keep it as
short as possible.
(9)Do not open the case of the inverter without any special circumstances; otherwise we will not
classify it as product warranty matter.
(10)Please keep this manual for future reference.
Attention:
A.Do not use in life-sustaining equipment without permission.
B.Do not use in high precision electrical equipment,need professional person`s confirmation.
C.Use to power computer,built-in power supply should be brand power.
Warring
No battery reverse connect.No wire zone line reverse connect. Do not using during flammable and explosive air. Pay attention to spark.
Please connect battery first then no disorder.
1.INV-A1 Solar inverter introduction:
This kind of power inverter upgraded and promote completely according to the adavantages and
disadvantages of old ones,use latest power efficiency technology.with high convert efficiency,stable
performance,low no load consumption,strong overload capacity,strong anti-jamming capability;
supply pure sine wave AC power for commercial,industry,communication,civilian,army.It is suitable
for DC12V 24V 48V 72V Solar power system,power air condition,TV set,cash register,fridge,
washing machine,computer,electrical tool,lighting,industry equipment,communication
equipment.etc.
2.F
unction:
(1)
:Description of the diagram
A、Give priority to the use of AC
Step1:When Utility Grid input is normal,AC power the load directly and recharge battery.
Step2:When Utility Grid shut off,the system will switch to give priority to the use of DC in 5ms automatically, ensuring normal working.
Step3:When Utility Grid is recovery, system will switch to give priority to use of AC and recharge
battery.
B、Give priority to the use of DC
Recharge battery mainly from solar energy,Utility Grid assist recharging.
Step1:When Utility Grid is normal,voltage of battery higher than 11V,DC turn into AC through inverter and power load.
Step2:When the voltage of battery is lower than 11V,the system switch to Utility Grid automatically and recharging battery.
Step3:When the voltage of battery up to 13.5V, system switch to photovoltaic power and power the load.
Step4:When both Utility Grid and photovoltaic power broke down, battey will shut off when voltage lower than 10v If Utility Grid is normal,AC will power load and recharge the battery.
If Utility Grid still broke down, photovoltaic power recharge battery until voltage up to 12v and turn on with conversion mode.
(2): Intelligent charge
1) Charge different kinds of batteries,refer to the parameter of product(page five of this
manual)
2)Three charge stages
Stage 1: the charger will run at full current in CC mode until the charger reaches the boost voltage.
Activate battery,promote power.(constant-current charging)
Stage2: the charger will keep the boost voltage in Boost CV mode.give battery enough time to absorb
energy,protect battery and electrode form over charge,extend life time.(constant-voltage charging)
Stage3:when the battery is full,It will turn into float voltage automatically to keep full power and
check battery power all the time,stop working when charge finish to save power..(Float charging)
(4)Power save mode(detect time is 5s):when boot under this mode,no load power consumption is
1w-6w,only CPU works,It will detect system cyclically,when load more than 30w ,system will boot
and enter normal working mode ,when load is less than 30w,It will enter energy-saving mode
in5s.This mode save unnecessary power.
3.Characters
1Pure sine wave output; do not harm electrical equipment, effective protection of the load; comes
with UPS conversion function, high-speed conversion, the conversion time less than 5ms; ensure
uninterrupted electricity;
2CPU management, intelligent control, modular composition, which is more convenient for
after-sale maintenance;
3、LED + LCD display, a visual display of all operating parameters of the machine,
4、High conversion efficiency,The conversion efficiency is 90-95% in half load situation ; more
than 99% in commercial situation; low-consumption, under the save power mode,the consumption is
between 1W ~ 6W; High efficiency and energy conservation.
5、Increased electricity auxiliary charging function; powerful charging function, three-stage
intelligent charging for different types of batteries, such as sealed lead-acid batteries, open lead acid
batteries, gel batteries, seven kinds of batteries,Note:lithium batteries need to setting as customers
use specifications before the delivery.
6、Intelligent temperature control fan, more energy and longer life.
7This series of products with a carrying capacity, superior anti-load capacity, it can with load of
water pumps, air conditioners, refrigerators, etc.rated power 1KW inverter can drive 1P air
conditioning, rated power 2KW inverter can drive 2P air conditioning, 3KW inverter 3P can drive air
conditioning
8、Using the most advanced frequency circuit design, with a new top-level electronic material, good stability, low failure rate, long life, normal use life can reach more than eight years;
9、Perfect protection features: Low voltage protection, high voltage protection, high temperature
protection, short circuit protection, leakage protection, over-current protection, over-load protection,
low voltage recovery, high voltage recovery, Intelligent temperature control fan, fault alarm, fault
recovery etc comprehensive protection
10、Power efficiency designing,resisting harmonic wave and inductive load ,safe and stable.
11、The frequency of 50/60HZ automatic selection,give priority to use AC and DC with automatic adjustment.display dynamic schematic diagram,comprehensive functions.easier to use.
12Pure copper transformer , blind post and wire.High density conformal coating.Double ball
bearing mute dc fan,Large LCD screen,Large current terminals,Best electric components,best
packing,safe,efficient and high level.
4.Type and specification
Specification Type Discribtion
DC12V-AC220V
300W,600W,800W,1KW,1.5KW,2KW
3KW
1:AC voltage
AC110V/100V/120V/230V/ 240V 2:Charge from Utility Grid,UPS function 3:Frequency 50HZ/60HZ
automatic selection
DC24V-AC220V
300W,600W,800W,1KW,1.5KW,2KW
3KW,4KW,5KW,6KW
DC48V-AC220V
300W,600W,800W,1KW,1.5KW,2KW 3KW,4KW5KW,6KW,7KW8KW 10KW12KW
DC72V-AC220V
1.5KW,2KW,3KW,4KW,5KW,6KW 7KW8KW10KW12KW
postscriptDC36V and any other would be customized.)
5.Parameters
Solar inverter parameters specifications
Power Specifications 300W~12KW
DC Input Specifications
Rated Voltage Specifications DC12/24/48/72V-AC220V DC12/24/48/72V-AC110V
Operating Voltage Range(Normal Operating Battery Voltage)
10V-16V (DC12V) 20V-32V (DC24V) 40V-64V (DC48V)
60V-96V (DC72V) Low Voltage Alarm(alarm to alert users when battery’s voltage is over low)
10.5Vdc ± 0.3Vdc 12V
21.0Vdc ± 0.6Vdc 24V
42.0Vdc ± 1.2Vdc 48V
63.0vdc ± 1.8Vdc 72V
Low Voltage Shut off (shut off when battery’s voltage is over low)
10.0Vdc ± 0.3Vdc 12V
20.0Vdc ± 0.6Vdc 24V
40.0Vdc ± 1.2Vdc 48V
60.0Vdc ± 1.8Vdc 72V Low Voltage Recovery (Automatic Boot when battery’s voltage returns to normal)
12.0Vdc ± 0.3Vdc (12V)
24.0Vdc ± 0.3Vdc (24V)
48.0Vdc ± 0.3Vdc (48V)
72.0Vdc ± 0.3Vdc (72V) High Voltage Alarm and shut off ( alarms and shut off when the battery’s voltage is over high)
16Vdc ± 0.3Vdc 12V 32Vdc ± 0.6Vdc 24V 64Vdc ± 1.2Vdc 48V 96Vdc ± 1.8Vdc 72V
High Voltage Recovery (Automatic boot when battery’s voltage returns to normal)
15.5Vdc ± 0.3Vdc(12V
31.0Vdc ± 0.6Vdc(24V
62.0Vdc ± 1.2Vdc(48V
93.0Vdc ± 1.8Vdc(72V
Inverter Efficiency ≥90% DC-priority type, battery low voltage conversion point when there is utility electricity bypass ( battery voltage is lower than this, turn to utility electricity to supply)
11Vdc ± 0.3Vdc 12V 22Vdc ± 0.6Vdc 24V 44Vdc ± 1.2Vdc 48V 66Vdc ± 1.8Vdc 72V
DC-priority type, after turning to utility electricity to supply, the battery low voltage recovery point (when
the battery’s voltage is higher than this, turn to battery to supply electricity)
13.5Vdc ± 0.3Vdc 12V
27.0Vdc ± 0.6Vdc 24V
54.0Vdc ± 1.2Vdc 48V
81.0Vdc ± 1.8Vdc 72V
AC Input Specifications
Rated Voltage Specifications 220VAC System 110VAC System
Input Voltage Waveform
Sine wave (utility electricity or generator)
Sine wave (utility electricity
or generator) Rated Input Voltage 220Vac/230Vac/240Vac 110Vac/120Vac/130Vac Low Voltage Shut off 180Vac±4% 85Vac±4% Low Voltage Recovery 195Vac ±4% 90Vac ±4% High Voltage Shut off 260Vac±4% 135Vac±4% High Voltage Recovery 255Vac±4% 130Vac±4%
Utility Electricity Charging rule
Three Stages: Constant current charging (constant stage)→constant voltage(constant voltage stage)→float (constant voltage stage)
Utility Electricity Supply ≥98%