Orno OR-DC-619 Quick Start Manual

1
Remove the three enclosed AA batteries and install them into the battery box. Observe the battery polarity markings at the bottom of the battery box.
When the batteries are first installed, the unit will beep one time and the red , green and yellow LEDs will flash one by one. “888 ppm will be displayed with blue backlight. After approximately 1 minute -2 minutes, the display and backlight will be off and the green light will flash every 4 seconds indicating that the unit is operational. Fit on battery cover. Your CO detector is now operational.
Carbon Monoxide Detector (Digital Display)
Model Number: OR-DC-619
Specifications:
Alarm Condition: EN50291 -1:2010 +A1:2012 Sensor: ECO-cellElectrochemical carbon monoxide sensor with more than 7
years lifetime
Power: 3 x1.5V AA alkaline batteries Temperature: Operating range -20°C to 50°C Humidity: Operating range 5%-100% relative humidity. Mounting: Accessories supplied for wall mounting Alarm: 85+ dB on 1m @ 3.4 ± 0.5 KHz pulsing alarm Test/Reset Button: Test button verifies proper unit operation. Accuracy of Digital Display: 25-999 ppm (±15%) when measured in condition
of 20˚C (±5˚C). Atmosphere pressure ±10% and 40% (±5%) relative humidity.
Size & Weight: 122mm×77mm×35mm /120g without battery Sensor Life Time: six years from first powered on but no longer then seven
years from production date printed on back side of unit. Warranty: Six-year limited warranty from date of purchase against defects in material and workmanship on CO detector unit.
Quick Set Up
Caution: Please do not press the test/reset button when you install the batteries!!!
2
LCD Display
LCD Display Shows
Alarm Sound
Units Status
Recommendation
“for example”
A display of CO concentration from 30-999 ppm. Blue backlight is lighted. Red LED flashes.
4 quick beeps, Repeated every 5 seconds.
Concentration of CO detected. Alarm condition.
Refer to “What to
do When the Alarm
Sounds”.
ttt displayed on
the LCD. Red LED, Green LED, Yellow LED will flash one by one.
One short beep on the beginning of self-test.
ttt means the detector is on self-testing.
If the status of the detector is normal, the LCD will display PAS. If the status is unnormal, Err will be displayed with two short beeps every 60 seconds.
Brief “888 ppm for approximately 1minute~2minute s. Blue backlight led is lighted at the same time.
None. (beep one time when install batteries is normal )
Self test when first powered up.
CO has not been detected. Numbers shown for test purpose only.
Display is blank. Green LED flashes every 4 seconds.
None.
Normal DC operation with good batteries. (now detecting CO)
None.
“Lb” displayed. Yellow LED flashes every 60 seconds.
One quick beep every 60 seconds
Batteries need to be replaced.
Replace all three AA batteries immediately.
“Err” displayed Yellow LED flashes every 60 seconds.
Two quick beeps every 60 seconds.
Unit is Error condition.
Unit has malfunctioned. Replace immediately.
HHH” displayed Blue backlight is lighted. Red LED flashes.
4 quick beeps, Repeated every 5 seconds.
Concentration s of CO is more than 999 ppm.
MOVE TO
FRESH AIR IMMEDIATELLY!!!
“End” displayed. Red LED flashes every 20 seconds.
Two quick beeps every 20 seconds.
End of unit life. About 72 months from first powered on.
Replace unit immediately.
Operating and Alarm Characteristics
Loading...
+ 4 hidden pages