ELECTRICAL ADJUSTMENTS
10
Kohm
AGC TP210
4. Activate the adjustment mode display (Fig.
2-3)
and
press the 2 key.
5. Adjust VOL. UP/DOWN key on the remote control until
the waveform maker
(45.75MHz)
becomes as shown in
Fig. 2-4-b.
6.
7.
6.
9.
45.75 MHz
x
Fig. 2-4-t
_
Disconnect output terminal 01 the sweepmarker generator
from
TP201,
then connect it to TP al the tuner pack.
Disconnect the
10K
ohm and the
2.7K
ohm variable
resistors.
Disconnect input and output terminals of the
sweepmarker generator.
Connect the AFT adjustment oscillator
(45.75MHz)
to TP of the tuner pack.
1 O.Connect the digital voltmeter to TP206.
1
l.Activate
the adjustment
mode
display (Fig. 2-3) and press
the 3 key.
12.Adjust
VOL. UP/DOWN key on the remote control to find
the point where the voltage of
TP206
changes dramatically,
and adjust to
4.5VDC
at that point.
2-2: BRIGHT, AGC, TINT AND COLOR
2-2-A: BRIGHT
1.
Receive the monochrome pattern.
2. Activate the adiustment mode displav
(Fig. 2-3)
and
press the 7
ke;.
,.
”
3. Press the VOL. UP/DOWN key on the remote control
until the boundary between 0% and 10% white starts
to become visible.
2-2-B: AGC
NOTE
Adjust after performing adjustments in section 2-1.
In case of weak electric field.
1. Tune to a noisy channel.
2. Activate the adjustment mode display and press
the 4 key.
3. Press the VOL. UP/DOWN key on the remote control
until noise is at minimum.
4.
Change the channel. confirm that the other channels
are normal.
In case of strong electric field.
(Radio frequency interference can
cause
diagonal
streaks to appear.)
1. Activate the adjustment mcde display and press
rhe
4
key.
2.
Press the VOL. UP/DOWN key 0” the remote
control untit
diagonal streaks are at minimum.
3. If there is still a problem after pressing the VOL. UP/DOWN
key on the remote control. install an attenuator to the
antenr,
terminals. then repeat step
1.
4. Confirm that noise does not appear.
5. Change the channel. confirm that the other channels are
normal.
2-2-C: TINT
1.
Receive the color bar pattern.
2. Connect the oscilloscope to TP023.
3. Activate the adjustment
mode
display (Fig. 2-3) and press
the 6 key.
4. Press the VOL. UP/DOWN key on the remote control
until
the waveform becomes as shown in Fig.
2-5.
1
I
Fig.
2i
2-2-D: COLOR
1.
Receive the color bar pattern.
2. Connect the oscilloscope to TP022
3. Activate the adjustment mode (Fig. 2-3) display and press
the 5 key.
4. Adjust the VOLTS RANGE VARIABLE knob of the
oscilloscope until the range between white 0% and 1 CO%
is set to 5 scales on the screen of the oscilloscope.
5. Press the VOL. UP/DOWN key an the remote control
untii
the red color level is adjusted to
4.75scalesf95%1
for
:he
white level. (Refer to Fig. 2-6)
I
b+4
I
I
95%
LL
h-
J
--OX
k
I-_-_-
--
100%
7