Orion OT-U250PP, OT-U500PP Installation And Use Manual

Page 1
Installation and use manual
for OT-U250PP & OT-U500PP
Page 2
Installation and use manual for OT-U250PP & OT-U500PP
Contents
Package Content ........................................................................................................................................ 3
1.
Introduction of the Product ....................................................................................................................... 3
2.
Conditions of use and Warnings ................................................................................................................ 3
3.
Installation TIPS for fogging systems – RECOMMENDATION .................................................................... 4
4.
Technical Specifications ............................................................................................................................. 5
5.
How to Activate the System ...................................................................................................................... 5
6.
Main Power supply .................................................................................................................................... 6
7.
Power supply connections ......................................................................................................................... 7
8.
Description of input and output connections ........................................................................................... 7
9.
INPUTS ............................................................................................................................................... 7
9.1.
+ 12V Power input ..................................................................................................................... 7
9.1.1.
INPUT SIGNALS .......................................................................................................................... 8
9.1.2.
VALIDATION INPUT .................................................................................................................... 8
9.1.3.
OUTPUTS............................................................................................................................................ 8
9.2.
Example ................................................................................................................................................. 9
10.
Example of connection of inputs with outputs of a standard alarm system ................................ 9
10.1.
Example of connection of inputs to an alarm with relay outputs ................................................. 9
10.2.
Example of connection of inputs with outputs of an alarm with open collector outputs .......... 10
10.3.
Example of connection of outputs to drive LEDS and / or relays ................................................ 10
10.4.
Example of connection of outputs with inputs of an alarm normally opened............................ 11
10.5.
Example of connection of outputs with balanced inputs of an antitheft.................................... 11
10.6.
Example of connection of outputs with anti-robbery connection. ............................................. 12
10.7.
Meaning of front LEDS ......................................................................................................................... 12
11.
Shooting time setting and fog Flow direction. .................................................................................... 13
12.
FOG FLOW DIRECTION ................................................................................................................. 14
12.1.
Nozzle Tamper ..................................................................................................................................... 15
13.
Installation, Exchange and Bag reset ................................................................................................... 15
14.
Maintenance ........................................................................................................................................ 16
15.
Reset from Fault condition .................................................................................................................. 17
16.
Defects Possible solution ..................................................................................................................... 17
17.
Warranty .............................................................................................................................................. 19
18.
Page 3
Installation and use manual for OT-U250PP & OT-U500PP
Package Content
1.
Inside the package you will find:
1. The machine OT-U250PP or OT-U500PP.
2. One 1000 ml bag.
3. A label to indicate the device presence.
4. Installation and use manual (this manual)
Introduction of the Product
2.
Thank you for purchasing Orion Technology product. The great patented technological innovations such as the liquid injection system, the fact with the heating system, all of them make the FAST fog generators the best fog devices with the best performance in the security market.
- Simple: Easy to install machines Can be integrated to any existing alarm system
Conditions of use and Warnings
3.
The fog generated by Orion Technology does not create particular problems or injuries for a human being for a short stay in a fogged room if the system is used according to the manufacturer’s recommendations. Generated fog is certified as safe for people and animals from an authorized international certification company and is proved that it does not leave any residual. The systems are certified respecting European laws and regulations. Any certifications required in specific countries are a responsibility of the distributor of that specific country. The documents related to certifications can be requested by mail to admin@orion-technology.dk. It is not guaranteed by the manufacturer the use of Orion Technology system in the presence of objects that may be damaged anyway by the contact with substances based on glycol, water and alcohol. Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above. At the date of printing of this manual it has never been pointed out any problem related to any allergy. Orion Technology is in no way responsible for any damage or condition of use that has not been required and specifically approved by any specific written request prior to the installation of its products. For fog fluid please refer to Orion Technology fluid safety data sheet published on the website and carefully read it at www.Orion-technology.eu. Contact a doctor if for any reason you swallow fog fluid or if after contact with eyes or skin you have any kind of reaction, and in any case wash it immediately with water and soap. Do never stay for a long time in a room filled with fog. Do not use charged bags that are not the ones suggested by Orion Technology and never try to recharge them, they are made for a single use. Follow your national rules for the dispose of empty bags. Keep Orion Technology bags out of reach of babies and animals. The nozzle may be hot and touching it may cause burns. Do not look directly into the nozzle. Never use Orion Technology products for any purpose that is not related to protection from thief or robbery (the choice of the conditions of use in case of robbery will be suggested by your security consultant). Never use different fog fluids or add any other substance into the bags. Do not use or keep charged Orion Technology machines in vehicles and do never transport Orion Technology before 24 hours since it has been shut off. During transport it must be not armed.
Page 4
Installation and use manual for OT-U250PP & OT-U500PP
Installation TIPS for fogging systems – RECOMMENDATION
4.
Please observe the following instructions for installing Orion Technology:
1. The machine must be installed avoiding obstructing escape routes.
2. Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause:
falls down, injuries or any damage to persons.
3. Do not look directly into the nozzle. Do not add any other substance into the bags.
4. The nozzle may reach high temperatures, touch it may cause burns.
5. When Orion Technology produces fog avoid staying closer than 1 meter from the machine.
6. When Orion Technology is armed avoid staying closer than 50 cm from the nozzle.
7. Before testing Orion Technology, remember to report it in advance to the firefighters in your area
to avoid false alarms.
8. Remember to put warning labels about the presence of Orion Technology on the windows.
9. Report its installation to the firefighters in your area and eventually to other institutions if needed.
10. It is necessary to add an external switch to separate the fog generator from the alarm system and it
should be activated before the maintenance to avoid that input tests, for example, can activate the fog generator.
11. Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase
the suggested minimum distance. Thanks to the power of the jet, Orion Technology reaches and exceeds more than 10 meters away in the first 3 seconds from the point where the machine is installed.
12. Setting the shooting time interval between the minimum and maximum shown in the shooting
table, avoid “overshooting” even if the produced fog is dry and generally doesn’t leave residue. A shot that goes far beyond the recommended seconds can create a residue problem in the room.
13. Orion Technology continues to be effective for up to 2 hours without 220V main power thanks to
the insulation system which maintains the temperature in the heating system.
14. Install at a height of about 2.5 meters not to let it be reached, avoiding possible tampering.
15. Install with a maximum inclination of 20°.
16. Do not move the machine when it is still hot.
17. The main body of Orion Technology, which has the heating system enclosed inside a metal frame,
should not be opened unless by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours Orion Technology has been shut off. The internal part may reach really high temperature.
18. Do not activate the Orion Technology machine before the installation is completed.
19. Insert the bags as the last procedure and verify the anti-tampering function.
20. When the installation is finished, always test the system.
21. From the moment of Orion Technology activation, at least one hour is necessary to reach the
minimum temperature needed for the fog shooting.
22. Install Orion Technology avoiding any obstacles in front of it which can prevent the spreading of the
fog.
23. The external temperature of Orion Technology can change from room temperature to 50 °C.
24. The tip of a stranded conductor should not be soft-soldered where the conductor is subjected to
contact pressure.
25. The Orion Technology machine should not be exposed to water spray or dripping.
26. Request to Orion Technology or its distributors to take part in courses for installers to ensure the
optimal installation of the equipment.
Page 5
Installation and use manual for OT-U250PP & OT-U500PP
Technical Specifications
5.
OT-U250PP OT-U500PP Weight without tanks 11,8 KG 15,0 KG Max fog emission in a single shot 200 m3 400 m3 Total fog emission capacity 900 m3 1800 m3 Fog bag capacity 1 x 1000 ml 1 x 1000 ml Working time without mains power 2 hours 30 min. 2 hours Max power on heating system 300 W 300 W Average power consumption during heating 270 W 270 W Heating time about 50 minutes about 2 hours Maximum consume at 12 V 45 W 42 W Maximum current consumption at 12 V 4A 4A Batteries type Pb 2 Ah 12V Pb 2 Ah 12V Door tamper screw to ground screw to ground Anti-tear off and anti-shift Accelerometer Accelerometer
The “empty” signal doesn’t mean only that the bag is empty, but also warns you that the system has shot at least 100 seconds. For this reason is very important to make the “reset” only when you really exchange the bag, or you will lose the seconds counting. (See paragraph 14)
How to Activate the System
6.
It is always recommended to fix the fog generator to a wall even when it is placed on a flat surface. The optional bracket, mainly recommended for ceiling installation, can also simplify standard installation, by allowing to use back holes for the passage of cables. Remember to
use the fixing screw placed in the bag compartment. Always verify that the bracket or the support surface are suitable for the weight of the machine. It is suggested not to install the machine behind walls in a limited closed area without a specific ventilation, in order to prevent a possible overheating. CAUTION: to avoid injuries please securely fix the fogging machine to the wall according to the installation instructions. In case of installation behind a wall, it is possible to request a nozzle extension, (7 cm).
After removing the machine from the package, unscrew the two screws that stop the right side panel and remove it. Remove tamper screw and shell screws from inside. At this point it is possible to remove frontal shell and see electronic circuit, from here on called PCB.
To open the additional compartment in the lower part, it is necessary to remove bag compartment’s door and take off the frontal shell, unscrew and remove the screws below. The screw in lower left part of bag compartment’s door is longer than the others and its removal activates the tamper output.
Page 6
Installation and use manual for OT-U250PP & OT-U500PP
The screw in lower left part of bag compartment’s door is longer than the others and its removal activates the tamper output. After the screw has been positioned correctly, the machine emits 4 beeps and deactivates tamper output.
Main Power supply
7.
220V-230VAC power source supplies energy only to the heating system. The electronic board and the bag’s pump are supplied from the alarm system and batteries. The heating element is of 0,3KW, at the very beginning power consumption is about 250W and in some minutes it goes down reaching average consumption is about 40W - 60W.
Do not use inverter or UPS if you are not sure that they generate a true sine wave, not a rebuilt one. Ask please to the UPS manufacturer the correspondence of such features before proceeding with the connection.
The max current to be considered for the system is 4A
The connection to the 230V electricity grid must be performed by a qualified technician.
Connect the equipment to the electricity grid only after you have completed the installation.
It is necessary to connect the ground terminal.
The system must be connected to the mains trough on automatic switch:
(automatic switch, curie C, with Ih= 10 A and Idif= 30 mA,...) with breeching capacity based on the assumed fault current of the fogging system in the sampling point.
PLEASE NOTE THAT, AS ALL POWERED EQUIPMENT FROM THE ELECTRICITY GRID REQUIRING INSTALLATION, IT IS SUBJECT TO COMPLIANCE WITH RULES OF THE COUNTRY IN WHICH IT IS INSTALLED For section and types of wires, fuses, suitability of materials to installation sites etc..
IF YOU NEED TO REPLACE THE FUSE, USE ONLY FUSE WITH THE FOLLOWING SPECIFICATIONS: CERAMIC BODY FILLED WITH QUARTZ, REF. STD. EN60127-2-3/DIN41660 3,15AH (EXAMPLE OMEGA GT520231)
Page 7
Installation and use manual for OT-U250PP & OT-U500PP
Power supply connections
8.
The battery is necessary to use the system in a safe way. The battery is recharged by power supply.
The placing of the lead-acid battery 2 Ah 12 V is in the case under the heat exchanger.
In order to accede to the battery case is necessary to remove the frontal cover and the 2 locking
screws.
1) Power supply mains connections
2) Mains power
3) Ground connection
4) Battery holder (battery not included
Description of input and output connections
9.
INPUTS
9.1.
+ 12V Power input
9.1.1. In these inputs is necessary to provide a stable supply, between 11V and 14V DC from the alarm control
panel or from an external 12V power supply. This power is necessary to the operation of the LED. The heating system checking and the battery recharge, the logic part. In absence of voltage on this input, the logic part will continue to operate, but heating system and LEDS (except for the BLUE one, arm) will stop working. Until when the heating system allows (about 2.30 h) the machine may emit fog. After that time the PCB will switch off automatically.
Page 8
Installation and use manual for OT-U250PP & OT-U500PP
INPUT SIGNALS
9.1.2.
A
By connecting this input to positive, FOGGING SYSTEM is armed, blue frontal LED is switched on and
when the machine reaches proper temperature it means that it is ready for shooting. In case of alarm, opening ARM input, the fog emission stops immediately, even if the time set wasn’t reached.
S
Putting this input to positive, if FOGGING SYSTEM is hot and armed, starts fog emission for the set time
(see paragraph 12).
VALIDATION INPUT
9.1.3. In order to validate this input, it’s necessary to insert the jumper W4. This input automatically generates
AND function with input S. If any input receives the shooting command, the generator doesn’t emit fog if within 1 minute doesn’t receive the command also from the second input.
P+ Output positive to give power to a validation sensor or a remote control receiver, max 300 mA. P- Output negative to give power to a validation sensor or a remote control receiver, max 300 mA. PV Validation input. It’s possible to connect to this input a validation sensor with a contact normally closed
connected to the terminal P-. In order to check the correct operation of PV input, it’s necessary to remove the jumper W4. When AND function is disabled, to each opening of PV input you will hear a “beep” for 5’’. At the end of the test, re-establish AND function inserting jumper W4 again
OUTPUTS
9.2.
E
This output (NPN Open Collector) closes towards negative direction when the bag is empty. This output
(NPN open collector) closes towards negative when the fogging machine emitted fog for at least 100’’ or when the bag is empty. The signal is activated by a sensor that detects the absence of liquid just while shooting. The empty bag signal is deactivated only making the RESET (see paragraph 14). For this reasons, if the bag is not inserted, or there is an empty bag inside, FOGGING SYSTEM will detect it just after a shot.
F
This output (NPN Open Collector) closes towards negative when there is a malfunction (such as batteries
expired, fault of power supply or temperature control fault), which compromises the functioning of the device and which requires a technical action.
T
This output (NPN Open Collector) closes towards negative direction when you open the bag door or
when the accelerometer detects a sudden movement (such as the detachment from the wall).
C
This output (NPN open collector) closes towards negative only after that the system has emitted fog for
the set time. If the emission of fog is interrupted (if there is an interruption of ARM command, if the glycol finishes, if there is not thermal autonomy anymore) this output will not change its status.
Remember, it is necessary to connect all three outputs to an alarm central or an electronic panel that can see all those information in real time and take proper action. In order to avoid accidental activation with subsequent fog emission, the inputs are in
“negative security”, for this reason the disconnection of a wire does not cause activation. So it is necessary to check carefully the reliability of connections and protect the cables to the control panel to avoid the risk of accidental damages.
Page 9
Installation and use manual for OT-U250PP & OT-U500PP
Example
10.
1 Example of connection of inputs with outputs of a standard alarm system 2 Example of connection of inputs to an alarm with relay outputs 3 Example of connection of inputs with outputs of an alarm with open collector outputs 4 Example of connection of outputs to drive LEDS and / or relays 5 Example of connection of outputs with inputs of an alarm normally opened 6 Example of connection of outputs with balanced inputs of an antitheft 7 Example of connection of outputs with anti-robbery connection.
Example of connection of inputs with outputs of a standard alarm system
10.1.
In the diagram above the control panel, as example, provides to Orion Fogging system power supply between 11 and 14V DC 250 mA max. The ON/OFF output of this alarm is an Open Collector NPN opened when the system is off and it is stably closed to negative as long as the system turned on. The alarm output of the alarm is normally open and becomes positive during the alarm time.
Example of connection of inputs to an alarm with relay outputs
10.2.
ON/OFF output of this alarm central is an open relay when the system is off and it is stably closed to positive as long as the system is turn on.
Page 10
- 10 -
Installation and use manual for OT-U250PP & OT-U500PP
Example of connection of inputs with outputs of an alarm with open collector outputs
10.3.
Compared to B diagram, this alarm central has only open collector outputs. The simplest action to take is to use 2 relays to create a connection similar to the one shown in the previous diagram.
Example of connection of outputs to drive LEDS and / or relays
10.4.
In case of an empty bag, the EMP LED (EMPTY) will switch on. In case of a fault, the FLT LED (FAULT) will switch on. By opening the cylinders door, besides the TPR (TAMPER) turning on, the relay will switch as well.
Max power applicable on the outputs is 100mA
Page 11
- 11 -
Installation and use manual for OT-U250PP & OT-U500PP
Example of connection of outputs with inputs of an alarm normally opened
10.5.
The outputs shown in the diagram are not always necessary, but only in cases where the voltage of pull-up resistance is lower than that of power supply.
The outputs are normally opened and connected with input zones of the alarm control panel normally opened
Example of connection of outputs with balanced inputs of an antitheft
10.6.
In this diagram, by putting a resistance with a value required by the alarm control panel used, in Orion terminal with not used outputs the central will see the correct resistance. After the activation of an output, a pull-down will occur causing the alarm in the corresponding zone.
Page 12
- 12 -
Installation and use manual for OT-U250PP & OT-U500PP
Example of connection of outputs with anti-robbery connection.
10.7.
Using the special connector and enabling the option anti-robbery closing the Jumper W2, you will obtain the immediate emission of the fog for the seconds that you have set even if the fogging system is not armed.
N.B. Is recommend to use this function after a careful evaluation of the risks from a security consultant
Meaning of front LEDS
11.
LED BLUE
When ON it means the machine is armed and, if hot, it’s ready to shoot. Flashing means something is wrong.
LED RED
It is ON when the bag is empty
LED GREEN
Flashing means the heating process is in progress. In this step the machine is heating but is not ready to shoot. When ON (steady green light) means the machine is hot and ready for the fog emission
IF THE BLUE LED IS FLASHING, TOGETHER WITH A CONTINUOUS SOUND FROM THE BUZZER, A
PROBLEM IS DETECTED. SEE PARAGRAPH 16
The symbol of empty bag, has the meaning of “RESERVE” It means that, since the last bag reset the machine consumed at least 85% of the estimated range of the bag.
Page 13
- 13 -
Installation and use manual for OT-U250PP & OT-U500PP
Shooting time setting and fog Flow direction.
12.
To set the shooting time, after opening the cylinders compartment door, at the top of the PCB, facing the board you must move the jumper in left position P3 (closer to the buttons S1/S2). Then, holding down the button S1 “SET”, 6 LEDs on the front will flash and each flash is equivalent to one second. If you press the button again, the shooting time is not added to the one previously set, but will restart from zero.
N.B. Before opening side door ensure that the control panel is set to “service”, so that the opening of “anti-sabotage or tamper” circuit does not cause any shooting
There might be cases in which, due to specific characteristic of the location, nozzle type, levels of temperature and air pressure, degree of the fog density and light in the target area, the shooting time can be increased or decreased accordingly by referring to the following formula:
(HxLxP) x D x V x I
HxLxP--------Height x Width x Depth of the area to protect D-------------Density of the produced fog V-------------Temperature and air pressure R-------------Acceptable residue in case of saturation of V parameter I--------------Intensity of the surface light
The following guide indicate the suggested fog emission in relation to the number of seconds of shooting set in average condition of temperature, air pressure and humidity.
So these are the details for the OT-U250PP: Max. Shooting time per single Shoot: 30 seconds shooting speed: 8.5 cubic meters per second Bag Low fluid signal after 100 seconds (average) Total Bag shooting capacity: 116 seconds equivalent to 1500 cubic meters
SHOOTING TABLE OT-U250PP
m³ to
protect
Seconds of
emission
m³ to
protect
Second
of
emission
m³ to
protect
Second
of
emission 13 - 20 1 78 – 120 6 143 - 220 11 26 - 40 2 91 – 140 7 156 - 240 12 39 - 60 3 104 - 160 8 169 - 260 13 52 - 80 4 117 - 180 9 182 - 280 14
65 - 100 5 130 - 200 10 195 - 300 15
Page 14
- 14 -
Installation and use manual for OT-U250PP & OT-U500PP
SHOOTING TABLE OT-U500PP
m³ to protect
Seconds
of
emission
m³ to protect
Second
of
emission
m³ to protect
Second
of
emission
13 - 20 1 147 - 220 11 280 - 420 21 27 - 40 2 160 - 240 12 293 - 440 22 40 - 60 3 173 - 260 13 306 - 460 23
53 - 80 4 187 - 280 14 320 - 480 24 67 - 100 5 200 - 300 15 333 - 500 25 80 - 120 6 213 - 320 16 347 - 520 26 93 - 140 7 226 - 340 17 360 - 540 27
107 - 160 8 240 - 360 18 373 - 560 28 120 - 180 9 253 - 380 19 386 - 580 29 133 - 200 10 267 - 400 20 400 - 600 30
The first value indicates in m³ the area to protect, the second one indicates the seconds of emission. The value in m³ may vary depending on the density that you desire to obtain. Considering the first value you obtain a density that guarantees a visibility of zero meters. With the second value you obtain a density that guarantees a visibility of 1.5 meters. Naturally, in places where a slight residue is not a problem, it is possible to increase the time of shooting. We remind you that more fog is released more time it takes to have visibility again. Higher levels of fog over suggested limits may fill the room and leave a residue. Any residue usually goes away by itself within 24/48 hours, otherwise, being soluble in water, it is enough to use a wet cloth for cleaning. If you desire to obtain an average of 1 meter visibility after 60 seconds, as specified by the standard, as used as reference by all manufacturers of Fog generators, the number of shooting seconds must be doubled.
FOG FLOW DIRECTION
12.1.
To ensure the right direction of the fog flow, it is recommended to insert a screwdriver of the diameter of the hole and, without forcing, orient the nozzle in the correct fog emission direction. This allows you to clearly see the direction and keep it in place while tightening. To screw and unscrew the nozzle you should use a pair of pliers in good condition to avoid damaging the plating. Do not over screw the nozzle; it is sufficient that the Teflon nozzle does not move. Do not direct the fog jet towards objects and walls less than 2 meters away or to the floor if it is installed at a height lower than 2.50 meters (we advise against the installation on the floor).
WARNING! After the fog emission and for a few minutes the nozzle is very hot RISK OF BURNS IF TOUCHED by bare hands.
Page 15
- 15 -
Installation and use manual for OT-U250PP & OT-U500PP
Nozzle Tamper
13.
The check of the obstruction of the nozzle is done with a little air flow, while a sensor check the pressure of the internal circuit. In case the sensor detects an increase of the internal pressure, means that there is an obstruction inside the nozzle. In the meantime, the output of Tamper will be activated; the buzzer will emit a sound with a fast frequency with the flash of the red LEDs. This condition of the alarm will continue until the system is disarmed and armed again. As the little compressor that introduces the air flow emits some vibrations, its activation occurs only in the following cases:
When you press the button RESET for more than 5 seconds, besides the activations of the drop of
the motors, will start a cycle of monitoring of 15 minutes, in order to simulate the obstruction and check the correct working.
When the system is armed the cycle of monitoring starts. This cycle is the most important, because
as the system was disarmed probably was easier to go near the machine and obstruct the nozzle. After 15 minutes, the compressor will stop automatically. If the system is disarmed and armed again, the cycle will start again for 15 minutes.
After the emission of the fog, as normally the zone where the machine is installed is the last where
the visibility is reduced, the generator remains vulnerable, giving the possibility to who generated the alarm to attempt the sabotage. For this reason, after the emission of the fog the compressor will be activated for 15 minutes.
Do not obstruct the nozzle when the generator is armed and bag is in.
Installation, Exchange and Bag reset
14.
After removing the screws of the door, is sufficient to remove the bag and reset the LED of empty bag.
In order to make the reset the jumper P3 must be on the right position as you can see in the picture.
After that, insert a new bag until you hear the “click” of the plastic support entering in its housing, then close the door.
N.B. When you close the door, the buzzer will make a sound to confirm the tamper is closed. Attention: Before opening the side doors, make sure that the alarm control panel is in “service” mode, so that the opening of the “anti-sabotage or tamper” circuit does not cause
any alarm
Page 16
- 16 -
Installation and use manual for OT-U250PP & OT-U500PP
Maintenance
15.
Orion generators do not require special care however, it is recommended the support of qualified and authorized personnel for periodic annual monitoring, taking into account the following:
Annually verify the functioning of the pump.
Check the air tightness of the circuit and the switch functioning.
The efficiency of the batteries is crucial to guarantee the operation
CHECKING OF THE PNEUMATIC CIRCUIT AND THE PRESSURE CONTROL SYSTEM
THE TEST CAN BE DONE JUST BY QUALIFIED PERSONNEL
Before starting the test of the pressure control it’s necessary:
to remove the bag
to be sure that the nozzle is cold
to be sure that the nozzle tamper pump is activated
The pneumatic seal test must be done within a few seconds when the pump for nozzle tamper control is turned on, as the nozzle temperature rises rapidly reaching temperatures that may cause serious burns.
The air coming out of the nozzle exceeds 200° C. IT’S ADVISABLE TO USE GLOWES
1. Obstruct the nozzle with soft and insulating material (for example an eraser).
2. Keep the nozzle obstructed, press the button P3 previously moved in RESET position (see paragraph
14) and keep it pressed until you hear that the pump is activated.
3. Wait 30’’ for the activation of the buzzer.
4. Remove the obstruction taking away your hand quickly to avoid being in contact with the hot
emission of air.
The buzzer must stop.
If there is any loss inside the pressure circuit, within 30’’ the buzzer will be activated.
If after 30’’ you don’t hear the buzzer, may be a loss inside the circuit; please contact the service
center.
If after removing the obstruction the buzzer doesn’t stop, it means that there is an obstruction;
please contact the service center.
Page 17
- 17 -
Installation and use manual for OT-U250PP & OT-U500PP
Reset from Fault condition
16.
This process is useful to discriminate false interpretations of faults caused by electrical shocks or serious problems on power supply from thermal loop problems.
1. Serious fault signal occurs with a first phase when the buzzer emits a continuous sound for 20
minutes and blue led flashes, the output FAULT immediately switch (if the generator is disconnected and connected again you can go directly at point 3)
2. After 20 minutes, the buzzer stops, while blue led goes on flashing, the FAULT output remains
closed. This phase remains permanently, until the machine is completely disarmed.
3. When you connect again the machine, blue and red LEDs flash alternately and no sound is emitted.
This phase lasts for 30 minutes, then, the output FAULT is reset and the generator start to work again. If during this process the generator is disconnected, when you connect it again the time start again from the beginning and for 30 minutes.
If at the end of this process, the generator start to work again regularly is not necessary any further operation. If occurs again the fault condition within the following 20 minutes, it’s necessary a check from the assistance center, or to send the machine back to the factory.
Defects Possible solution
17.
DEFECT FOUND
POSSIBLE CAUSE
POSSIBLE SOLUTION
When you arm the machine you hear an internal buzz, like a motor
The compressor is checking that there are no obstructions in the circuit of fog emission
When the machine is armed, for 15 minutes the compressor will monitor the nozzle. After this time it will deactivate automatically: if the fogging system is disarmed, the compressor will go on with it reaches 15 minutes. If the machine is disarmed and then armed again, the count will start again from zero.
When you arm the fogging system, a little fog flow goes out from the nozzle even if the machine has never shot before
During testing phase in the factory, we also test the quality of fog in all produced systems, a little quantity of the fog liquid remains in the ducts
This emission occurs just at first activation, it will decrease visibly with any activation, until disappearing completely. After an eventual disassembly and reinstallation or after the transport of the machine, with the first activations a little
flow of fog can occur again. The 3 frontal LED are flashing and the buzzer emits 1 beep per minute
The tension on +12 V input is too low or too high
Check the external power supply or the
alarm unit
The buzzer emits 2 beep per minute
Low battery but possible shot
Verify/replace battery - See paragraph
MAINTENANCE The buzzer emits 3 beep per minute
Low battery but possible shot
Verify/replace battery - See paragraph
MAINTENANCE
The buzzer emits 10 continuous beep per minute
Batteries not present Insert battery Connector not inserted correctly Remove and reinsert the connector Verify that jumper W5 is inserted Insert jumper W5
The machine is armed (BLUE LED ON) but doesn’t shoot
The front RED LED is on
Bag reset has not been made Reset as
described in paragraph 15
Bag is in reserve or empty-Change the bag
as described in paragraph 15
The front GREEN LED flashes
The heat exchanger has not yet reached
the minimum temperature of shooting,
wait for the led to stop flashing standard
heating time: 60 min.
Page 18
- 18 -
Installation and use manual for OT-U250PP & OT-U500PP
The machine doesn’t shoot immediately after arming
For safety reasons and to avoid false fog
emissions during power on, when the
machine is armed, it becomes operative
only after 20’. After this time, the emission
is instantaneous.
Wiring error
Verify that the alarm, once activated has
tension on connectors of at least 12 V
between GND(5) + SHOOTS(4)
BLUE LED is flashing The buzzer emits a continuous sound BLUE and RED LEDS are flashing alternately
Overvoltage power line (110/220 V)
Try to reset. See paragraph 17
In case of unsuccessful restore the PCB can
be damaged, contact the assistance
service.
Over temperature of the PCB
Check there is sufficient ventilation around
the machine. See paragraph 17
To reset see paragraph 17
Disturbance/ interference or potential differences between devices
In the case of strong interference
(lightning) can occur a thermocouple
reading error, make a reset.
See paragraph 17.
In case of unsuccessful restore can be
occurred a potential difference or a fault.
In large size plants or with more than on
fogging system connected with the same
central, in rare situations, it may occur
that there are potential differences
between the equipment and it could be
necessary to uncouple
Error in the thermal loop
Possible fault of: thermocouple, resistance
or fuse cable. Don’t try to repair
Contact the assistance service center.
Impossible to arm the machine BLUE LED doesn’t switch on
Wiring error
Check on the terminal with a tester that
when the alarm system is tuned on there
is a minimum voltage of 11 V between -
GND (5) + ARM (3).
Cannot arm, BLUE LED does not become on.
Wiring error
Test the terminal that there is a minimum
voltage of between 11V - GND (5) + ARM
(3), when the anti-theft system is activated When you press the reset button you don’t hear the sound of the buzzer, the frontal LED are flashing but the RED LED does not reset
The Jumper P3 is in the “SET” position
Warning in this case shooting time is reset to zero Bag reset - Paragraph 15
Shooting time setting - Paragraph 12
Setting the shooting time, the buzzer does not sound and the LEDs do not flash
The jumper P3 stands in the “RESET” position
See the setting mode of the shooting time
at paragraph 13
Page 19
- 19 -
Installation and use manual for OT-U250PP & OT-U500PP
Warranty
18.
The warranty of Orion Technology is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to take advantage of warranty with the copy of the purchase document that contains the serial number of the machine. Not included in the warranty: moving parts and/or damages depending on the incorrect use unless it is found a manufacturing defect in origin. Liquid and bags are not covered by warranty.
BY BREAKING THE SECURITY LABELS AND THE OPENING OF THE MACHINE YOU WILL ACCEPT WHAT IS WRITTEN ON THIS MANUAL
Serial number..........…………………………………………………………......................
Date of installation..........…………………………………………………………......................
Signature of installer ..........…………………………………………………………......................
At the end of the installation, write down the identification number of the machines, the date of the installation and sign in the dedicated spaces.