Orion OT-U250PP, OT-U500PP Installation And Use Manual

Installation and use manual
for OT-U250PP & OT-U500PP
Installation and use manual for OT-U250PP & OT-U500PP
Contents
Package Content ........................................................................................................................................ 3
1.
Introduction of the Product ....................................................................................................................... 3
2.
Conditions of use and Warnings ................................................................................................................ 3
3.
Installation TIPS for fogging systems – RECOMMENDATION .................................................................... 4
4.
Technical Specifications ............................................................................................................................. 5
5.
How to Activate the System ...................................................................................................................... 5
6.
Main Power supply .................................................................................................................................... 6
7.
Power supply connections ......................................................................................................................... 7
8.
Description of input and output connections ........................................................................................... 7
9.
INPUTS ............................................................................................................................................... 7
9.1.
+ 12V Power input ..................................................................................................................... 7
9.1.1.
INPUT SIGNALS .......................................................................................................................... 8
9.1.2.
VALIDATION INPUT .................................................................................................................... 8
9.1.3.
OUTPUTS............................................................................................................................................ 8
9.2.
Example ................................................................................................................................................. 9
10.
Example of connection of inputs with outputs of a standard alarm system ................................ 9
10.1.
Example of connection of inputs to an alarm with relay outputs ................................................. 9
10.2.
Example of connection of inputs with outputs of an alarm with open collector outputs .......... 10
10.3.
Example of connection of outputs to drive LEDS and / or relays ................................................ 10
10.4.
Example of connection of outputs with inputs of an alarm normally opened............................ 11
10.5.
Example of connection of outputs with balanced inputs of an antitheft.................................... 11
10.6.
Example of connection of outputs with anti-robbery connection. ............................................. 12
10.7.
Meaning of front LEDS ......................................................................................................................... 12
11.
Shooting time setting and fog Flow direction. .................................................................................... 13
12.
FOG FLOW DIRECTION ................................................................................................................. 14
12.1.
Nozzle Tamper ..................................................................................................................................... 15
13.
Installation, Exchange and Bag reset ................................................................................................... 15
14.
Maintenance ........................................................................................................................................ 16
15.
Reset from Fault condition .................................................................................................................. 17
16.
Defects Possible solution ..................................................................................................................... 17
17.
Warranty .............................................................................................................................................. 19
18.
Installation and use manual for OT-U250PP & OT-U500PP
Package Content
1.
Inside the package you will find:
1. The machine OT-U250PP or OT-U500PP.
2. One 1000 ml bag.
3. A label to indicate the device presence.
4. Installation and use manual (this manual)
Introduction of the Product
2.
Thank you for purchasing Orion Technology product. The great patented technological innovations such as the liquid injection system, the fact with the heating system, all of them make the FAST fog generators the best fog devices with the best performance in the security market.
- Simple: Easy to install machines Can be integrated to any existing alarm system
Conditions of use and Warnings
3.
The fog generated by Orion Technology does not create particular problems or injuries for a human being for a short stay in a fogged room if the system is used according to the manufacturer’s recommendations. Generated fog is certified as safe for people and animals from an authorized international certification company and is proved that it does not leave any residual. The systems are certified respecting European laws and regulations. Any certifications required in specific countries are a responsibility of the distributor of that specific country. The documents related to certifications can be requested by mail to admin@orion-technology.dk. It is not guaranteed by the manufacturer the use of Orion Technology system in the presence of objects that may be damaged anyway by the contact with substances based on glycol, water and alcohol. Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above. At the date of printing of this manual it has never been pointed out any problem related to any allergy. Orion Technology is in no way responsible for any damage or condition of use that has not been required and specifically approved by any specific written request prior to the installation of its products. For fog fluid please refer to Orion Technology fluid safety data sheet published on the website and carefully read it at www.Orion-technology.eu. Contact a doctor if for any reason you swallow fog fluid or if after contact with eyes or skin you have any kind of reaction, and in any case wash it immediately with water and soap. Do never stay for a long time in a room filled with fog. Do not use charged bags that are not the ones suggested by Orion Technology and never try to recharge them, they are made for a single use. Follow your national rules for the dispose of empty bags. Keep Orion Technology bags out of reach of babies and animals. The nozzle may be hot and touching it may cause burns. Do not look directly into the nozzle. Never use Orion Technology products for any purpose that is not related to protection from thief or robbery (the choice of the conditions of use in case of robbery will be suggested by your security consultant). Never use different fog fluids or add any other substance into the bags. Do not use or keep charged Orion Technology machines in vehicles and do never transport Orion Technology before 24 hours since it has been shut off. During transport it must be not armed.
Installation and use manual for OT-U250PP & OT-U500PP
Installation TIPS for fogging systems – RECOMMENDATION
4.
Please observe the following instructions for installing Orion Technology:
1. The machine must be installed avoiding obstructing escape routes.
2. Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause:
falls down, injuries or any damage to persons.
3. Do not look directly into the nozzle. Do not add any other substance into the bags.
4. The nozzle may reach high temperatures, touch it may cause burns.
5. When Orion Technology produces fog avoid staying closer than 1 meter from the machine.
6. When Orion Technology is armed avoid staying closer than 50 cm from the nozzle.
7. Before testing Orion Technology, remember to report it in advance to the firefighters in your area
to avoid false alarms.
8. Remember to put warning labels about the presence of Orion Technology on the windows.
9. Report its installation to the firefighters in your area and eventually to other institutions if needed.
10. It is necessary to add an external switch to separate the fog generator from the alarm system and it
should be activated before the maintenance to avoid that input tests, for example, can activate the fog generator.
11. Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase
the suggested minimum distance. Thanks to the power of the jet, Orion Technology reaches and exceeds more than 10 meters away in the first 3 seconds from the point where the machine is installed.
12. Setting the shooting time interval between the minimum and maximum shown in the shooting
table, avoid “overshooting” even if the produced fog is dry and generally doesn’t leave residue. A shot that goes far beyond the recommended seconds can create a residue problem in the room.
13. Orion Technology continues to be effective for up to 2 hours without 220V main power thanks to
the insulation system which maintains the temperature in the heating system.
14. Install at a height of about 2.5 meters not to let it be reached, avoiding possible tampering.
15. Install with a maximum inclination of 20°.
16. Do not move the machine when it is still hot.
17. The main body of Orion Technology, which has the heating system enclosed inside a metal frame,
should not be opened unless by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours Orion Technology has been shut off. The internal part may reach really high temperature.
18. Do not activate the Orion Technology machine before the installation is completed.
19. Insert the bags as the last procedure and verify the anti-tampering function.
20. When the installation is finished, always test the system.
21. From the moment of Orion Technology activation, at least one hour is necessary to reach the
minimum temperature needed for the fog shooting.
22. Install Orion Technology avoiding any obstacles in front of it which can prevent the spreading of the
fog.
23. The external temperature of Orion Technology can change from room temperature to 50 °C.
24. The tip of a stranded conductor should not be soft-soldered where the conductor is subjected to
contact pressure.
25. The Orion Technology machine should not be exposed to water spray or dripping.
26. Request to Orion Technology or its distributors to take part in courses for installers to ensure the
optimal installation of the equipment.
Installation and use manual for OT-U250PP & OT-U500PP
Technical Specifications
5.
OT-U250PP OT-U500PP Weight without tanks 11,8 KG 15,0 KG Max fog emission in a single shot 200 m3 400 m3 Total fog emission capacity 900 m3 1800 m3 Fog bag capacity 1 x 1000 ml 1 x 1000 ml Working time without mains power 2 hours 30 min. 2 hours Max power on heating system 300 W 300 W Average power consumption during heating 270 W 270 W Heating time about 50 minutes about 2 hours Maximum consume at 12 V 45 W 42 W Maximum current consumption at 12 V 4A 4A Batteries type Pb 2 Ah 12V Pb 2 Ah 12V Door tamper screw to ground screw to ground Anti-tear off and anti-shift Accelerometer Accelerometer
The “empty” signal doesn’t mean only that the bag is empty, but also warns you that the system has shot at least 100 seconds. For this reason is very important to make the “reset” only when you really exchange the bag, or you will lose the seconds counting. (See paragraph 14)
How to Activate the System
6.
It is always recommended to fix the fog generator to a wall even when it is placed on a flat surface. The optional bracket, mainly recommended for ceiling installation, can also simplify standard installation, by allowing to use back holes for the passage of cables. Remember to
use the fixing screw placed in the bag compartment. Always verify that the bracket or the support surface are suitable for the weight of the machine. It is suggested not to install the machine behind walls in a limited closed area without a specific ventilation, in order to prevent a possible overheating. CAUTION: to avoid injuries please securely fix the fogging machine to the wall according to the installation instructions. In case of installation behind a wall, it is possible to request a nozzle extension, (7 cm).
After removing the machine from the package, unscrew the two screws that stop the right side panel and remove it. Remove tamper screw and shell screws from inside. At this point it is possible to remove frontal shell and see electronic circuit, from here on called PCB.
To open the additional compartment in the lower part, it is necessary to remove bag compartment’s door and take off the frontal shell, unscrew and remove the screws below. The screw in lower left part of bag compartment’s door is longer than the others and its removal activates the tamper output.
Installation and use manual for OT-U250PP & OT-U500PP
The screw in lower left part of bag compartment’s door is longer than the others and its removal activates the tamper output. After the screw has been positioned correctly, the machine emits 4 beeps and deactivates tamper output.
Main Power supply
7.
220V-230VAC power source supplies energy only to the heating system. The electronic board and the bag’s pump are supplied from the alarm system and batteries. The heating element is of 0,3KW, at the very beginning power consumption is about 250W and in some minutes it goes down reaching average consumption is about 40W - 60W.
Do not use inverter or UPS if you are not sure that they generate a true sine wave, not a rebuilt one. Ask please to the UPS manufacturer the correspondence of such features before proceeding with the connection.
The max current to be considered for the system is 4A
The connection to the 230V electricity grid must be performed by a qualified technician.
Connect the equipment to the electricity grid only after you have completed the installation.
It is necessary to connect the ground terminal.
The system must be connected to the mains trough on automatic switch:
(automatic switch, curie C, with Ih= 10 A and Idif= 30 mA,...) with breeching capacity based on the assumed fault current of the fogging system in the sampling point.
PLEASE NOTE THAT, AS ALL POWERED EQUIPMENT FROM THE ELECTRICITY GRID REQUIRING INSTALLATION, IT IS SUBJECT TO COMPLIANCE WITH RULES OF THE COUNTRY IN WHICH IT IS INSTALLED For section and types of wires, fuses, suitability of materials to installation sites etc..
IF YOU NEED TO REPLACE THE FUSE, USE ONLY FUSE WITH THE FOLLOWING SPECIFICATIONS: CERAMIC BODY FILLED WITH QUARTZ, REF. STD. EN60127-2-3/DIN41660 3,15AH (EXAMPLE OMEGA GT520231)