ORiNG TES-3082GT-M12-BP1 Quick Installation Manual

Quick InstallationGuide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
QIG
The is a managedEthernet switch designedfor industrial applications,such as rollingstock, vehicle, andrailway applications. Theswitch boasts EN50155 compliance and M12 connectors to ensure tight and robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. Besides eight 10/100Base-T(X) ports, the switch alsoprovides one set of bypass ports that ensure constant network connectivity if power outage or node failure occurs. In such situations, the device will bypass the inactive switch and continueto transfer networktraffic to thenext switch inthe relay.
TES-3082GT-M12-BP1
Package Contents
Installation
Wall-mount
The devicecan be fixedto the wall.Follow the stepsbelow to installthe device onthe wall.
Hold the evice upright against the wall Insert four screws through the large opening of the keyhole-shaped apertures at the
top and bottom of the unit and fastenthe screw tothe wall witha screwdriver.
Slide the evice downwards and tighten the four screws for added stability.
Step 1: Step 2:
Step 3:dd
The series is shipped with the following items. Ifany of these items is missing or damaged,please contact your customer service representative for assistance.
TES-3082GT-M12-BP1
Preparation
Before youbegin installing thedevice, make sureyou have allof the package contents availableand a PCwith Microsoft InternetExplorer 6.0 orlater, for using web-basedsystem management tools.
Elevated OperatingAmbient:
ReducedAir Flow:
Mechanical Loading:
Circuit Overloading:
If installedin a closed environment, makesure the operating ambient temperature is compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
Make surethe amount ofair flow requiredfor safe operation
of theequipment is notcompromised during installation.
Make surethe mounting ofthe equipment is not in a
hazardous conditiondue to unevenmechanical loading.
Consideration shouldbe given tothe connection ofthe equipment tothe supply circuitand the effectthat overloading ofthe circuits might haveon overcurrent protectionand supply wiring.Appropriate consideration ofequipment nameplate ratingsshould be used when addressing this concern.
Safety & Warnings
For pinassignments of power,console andrelay output ports,please refer tothe following tables.
Contents
TES-3082GT-M12-BP1
Pictures Number
1
CD
1
Dimension
Panel Layouts
Front View
1. Resetbutton
2. Power1status LED
3. Power2status LED
4. R.M.status LED
5. Ringstatus LED
6. FaultLED
7.Relayoutputport
8. Consoleport
9. Powerconnector
10. Ethernetports
11. LNK/ACTindicator for Ethernetport
12. Duplex/collisionindicator for Ethernetport
13. LNK/ACTindicator for GigabitEthernet port
14. Speedindicator for GigabitEthernet port
15. Gigabit Ethernet ports
Wiring
Grounding
Grounding andwire routing helplimit the effectsof noise dueto electromagnetic interference (EMI). Runthe ground connectionfrom the groundingpin on thepower connector tothe grounding surface priorto connecting devices.
Power portpinouts
The devicesupports two setsof power suppliesand uses theM23 5-pin female connector on the front panel for the dual power inputs.
Insert a power cableto the powerconnector on thedevice. Rotate theouter ring ofthe cable connectoruntil a snug fit is
achieved. Make sure the connection is tight.
Step 1: Step 2:
V1+
V1-
V2+
V2-
Relay outputport pinouts
Relay
N.C.
1A@24VDC
Network Connection
The switchhas eight 10/100Base-T(X)and two 10/100/1000Base-T(X)Ethernet ports inthe form of M12 connector.Depending onthe link type,the switch usesCAT 3, 4,5,5e UTPcables to connect to network devices (PCs,servers, switches, routers,or hubs). Pleaserefer to thefollowing table for cablespecifications.
4-Pin FastEthernet Port Definition
TES-3082GT-M12-BP1
TES-3082GT-M12-BP1
1907-2-29-TES3082GTM12-1.0
Switch
EN50155
EN50155 10-port managed
Ethernet switch
INDUSTRIAL
65.0
1
Instead ofscrewing the screwsin all theway, itis advised to leave aspace of about2mm to allowroom for slidingthe switch betweenthe wall andthe screws.
The switchuses the M12A-coded 5-pinmale connector on the frontpanel for relayoutput. Use apower cord withan M12A-coded 5-pin femaleconnector to connectthe relay. The relaycontacts will detectuser-configured events and form anopen circuit when an eventis triggered.
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4,5 100-ohm UTP100 m (328ft)
4-pin female M12
D-codingconnector
100BASE-TX Cat. 5100-ohmUTP UTP100m (328ft)
4-pin female M12
D-codingconnector
1000BASE-T Ca t.5/Cat. 5e 100-ohmUTP UTP 100m (328ft)
4-pin female M12
D-codingconnector
*2 (GxA&G xB)
For pinassignments of theLAN ports, pleaserefer to thefollowing tables.
QIG
1
170.1
196.0
R2.5
R4.00
155.8
75.0 21.3
15.0
6.50
178.0
151.6
132.1
G1B
G1A
G2B
G2A
Power Failure Bypass
P1 P5
P2 P6
P3 P7
P4 P8
LNK/ACT
DPX/COL
V1+
V1-
V2+
V2-
Power
Console
N.C.
RXD
RS-232,9600bps,8,N,1
GND
TXD
N.C.
3A@24VDC
Relay
N.C.
RelayOutput
FaultRingR.M.PWR2PWR1
TES-3082GT-M12-BP1
LNK/ACT
DPX/COL
LNK/ACT
DPX/COL
LNK/ACT
DPX/COL
GxA GxB
LNK/ACT
100M
Tx+
Rx+
Tx-Rx-
DA+
DB+
DA-DB-
DC+
DD+
DC-DD-
P1~P8
Power Failure Bypass
LNK/ACT
100M
Reset
G1B
G1A
G2B
G2A
Power Failure Bypass
P1 P5
P2 P6
P3 P7
P4 P8
LNK/ACT
DPX/COL
V1+
V1-
V2+
V2-
Power
Console
N.C.
RXD
RS-232,9600bps,8,N,1
GND
TXD
N.C.
3A@24VDC
Relay
N.C.
RelayOutput
FaultRingR.M.PWR2PWR1
TES-3082GT-M12-BP1
LNK/ACT
DPX/COL
LNK/ACT
DPX/COL
LNK/ACT
DPX/COL
GxA GxB
LNK/ACT
100M
Tx+
Rx+
Tx-Rx-
DA+
DB+
DA-DB-
DC+
DD+
DC-DD-
P1~P8
Power Failure Bypass
LNK/ACT
100M
Reset
7
8
9
10 12 15
2 3 4
6
5
11
14
13
2 Tx+
1
Rx+
Tx-4Rx-
3
Pin No. Description
#1
RD+
#2
TD+
#3
RD-
#4
TD-
4-Pin GigabitPort Definition
GxA GxB
2 DA+
1
DB+
DA-4DB-
3
2 DC+
1
DD+
DC-4DD-
3
Configurations
After installingthe router and connecting cables, start the evice by turning on power.The green powerLED should turnon. Please refer to the following tablet for LED indication.
d
Pin No. GxA Description
#1
DB+
#2
DA+
#3
DB-
#4
DA-
Pin No. GxB Description
#1
DD+
#2
DC+
#3
DD-
#4
DC-
QIG
Quick InstallationGuide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
ORing IndustrialNetworking Corp.
Copyright© 2014 ORing
All rightsreserved.
TEL: +886-2-2218-1066 FAX:+886-2-2218-1014
Website: www.oring-networking.com E-mail: support@oring-networking.com
Version 1.0
QIG
Specifications
Switch
EN50155
INDUSTRIAL
Power
RedundantInput Power
PowerConsumption(Typ.)
DualDC inputs. 12~48VDCon 5-pin M23connector
11Watts
Physical Characteristic
Enclosure
IP-30
Dimension(WxDxH)
125(W)x 65(D) x196(H) mm (4.92x 2.56 x7.66 inch.)
Weight (g)
1338g
Environmental
-40to85C(-40to185F)
oo
StorageTemperature
5%to 95% Non-condensing
OperatingHumidity
Regulatory Approvals
FCCPart 15, CISPR(EN55022) class A,EN50155 (EN50121-3-2, EN55011,EN50121-4)
EMI
EN61000-4-2(ESD), EN61000-4-3 (RS),EN61000-4-4 (EFT), EN61000-4-5(Surge), EN61000-4-6(CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27
Shock
IEC60068-2-32
IEC60068-2-6
Vibration
FreeFall
Warranty
5years
LED Indicators
PowerIndicator
Green:Power LED x2
EN60950-1
Safety
R.M.Indicator
Green:IndicatesystemoperatedinO-RingMastermode
10/100Base-T(X)M12 Port Indicator
Greenfor port Link/Act. Amber for Collision/Duplexindicator.
Fault Contact
Relay
Relayoutput to carrycapacity of 3Aat 24VDC onM12 connector (5-pinM12 A-coding)
OverloadCurrent Protection
ReversePolarity Protection
Present
Present
-40to70C(-40to158F)
oo
OperatingTemperature
ORing SwitchModel
10/100Base-T(X) Ports in M12Auto MDI/MDIX
8 xM12 connector (4pin D-coding)
Physical Ports
Technology
EthernetStandards
IEEE802.3 for 10Base-T IEEE802.3u for 100Base-TX IEEE802.3ab for 1000Base-T IEEE802.3x for Flowcontrol IEEE802.3ad for LACP(Link Aggregation ControlProtocol) IEEE802.1D for STP(Spanning Tree Protocol) IEEE802.1p for COS(Class of Service) IEEE802.1Q for VLANTagging IEEE802.1w for RSTP(Rapid Spanning TreeProtocol) IEEE802.1s for MSTP(Multiple Spanning TreeProtocol) IEEE802.1x for Authentication IEEE802.1AB for LLDP(Link Layer DiscoveryProtocol)
2KMAC addresses
MACTable
4
PriorityQueues
TES-3082GT-M12-BP1
LED Color Stat us Desc ription
PWR1 Green On DC power modul e 1 activated
PWR2 Green On DC power modul e 2 activated
R.M Green On Syst em running in Ri ng Master mode
On System running i n Ring mode
Ring G reen
Blinking Ring is brok en
Fault Amber On Errors occur (power f ailure or port link down)
10/100Base-T( X) Ports
On Port is linked
LNK/ACT Green
Blinking Transmitt ing data
On Port runnin g in full-d uplex mode
DPX/COL Amber
Blinking Collision occurs
10/100/1000Base- T Ports
On Port is linked
LNK/ACT Green
Blinking Transmitt ing data
100M Amber On Port spee d at 100M
1. Launchthe Internet Explorerand type inIP address ofthe device.The default static IP addressis 192.168.10.1
Follow thesteps below tolog in andaccess the system:
2. Login with defaultuser name andpassword (both are ).admin
3.After logging in,you should seethe following screen.For more informationon configurations, pleaserefer to theuser manual. Forinformation on operatingthe device using ORing’sOpen-Vision management utility, pleasego to ORingwebsite.
Resetting
Torestore the device configurations back to the factory defaults, press the button for a few seconds. Once the power indicator starts to flash, release the button. The device will then reboot and return to factory defaults.
Reset
10/100/1000Base-T(X)ports inM12
2x(combinig2xM12connectors4-pinD-codingfor1Gigabitport)
RS-232Serial Console Port
RS-232 inM12 connector (A-coding).Baud rate setting:9600bps, 8, N,1
Store-and-Forward
Processing
SwitchProperties
Switchinglatency: 7 us Switchingbandwidth: 5.6 Gbps Max.Number of AvailableVLANs: 4096 IGMPmulticast groups: 1024 Portrate limiting: UserDefine
SecurityFeatures
Enable/disableports, MAC basedport security Portbased network accesscontrol (802.1x) VLAN(802.1Q) to segregateand secure networktraffic SupportsQ-in-Q VLAN forperformance & securityto expand theVLAN space Radiuscentralized password management SNMPv1/v2c/v3 encrypted authenticationand access security
SoftwareFeatures
STP/RSTP/MSTP(IEEE 802.1D/w/s) RedundantRing (O-Ring) withrecovery time lessthan 10ms over250units TOS/Diffservsupported Qualityof Service (802.1p)for real-time traffic VLAN(802.1Q) with VLANtagging and GVRPsupported IGMPSnooping for multicastfiltering Portconfiguration, status, statistics,monitoring, security SNTPfor synchronizing ofclocks over network SupportPTP Client (PrecisionTime Protocol) clocksynchronization DHCPServer / Clientsupport PortTrunk support MVR(Multicast VLAN Registration)support ModbusTCP
NetworkRedundancy
O-Ring Open-Ring O-Chain MRP STP/RSTP/MSTP
Warning/ Monitoring System
Relayoutput for faultevent alarming Syslogserver / clientto record andview events IncludeSMTP for eventwarning notification viaemail Eventselection support
O-RingIndicator
Green:IndicatesystemoperatedinO-Ringmode
FaultIndicator
Amber:Indicate unexpected eventoccurred
10/100/1000Base-T(X)M12 PortIndicator
Greenfor Link/Act. Amber for 100Mbpsindicator
TES-3082GT-M12-BP1
TES-3082GT-M12-BP1
EN50155 10-port managed
Ethernet switch
Loading...