COPYRIGHT NOTICE
Copyright © 2016 ORing Industrial Networking Corp. All rights reserved. No part of this publication may be reproduced in any form without the prior written consent of ORing Industrial Networking Corp.
TRADEMARKS
is a registered trademark of ORing Industrial Networking Corp.
All other trademarks belong to their respective owners.
REGULATORY COMPLIANCE STATEMENT
Product(s) associated with this publication complies/comply with all applicable regulations. Please refer to the Technical Specifications section for more details.
WARRANTY
ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). ORing will repair or replace products found by ORing to be defective within this warranty period, with shipment expenses apportioned by ORing and the distributor. This warranty does not cover product modifications or repairs done by persons other than ORing-approved personnel, and this warranty does not apply to ORing products that are misused, abused, improperly installed, or damaged by accidents. Please refer to the Technical Specifications section for the actual warranty period(s) of the product(s) associated with this publication.
DISCLAIMER
Information in this publication is intended to be accurate. ORing shall not be responsible for its use or infringements on third-parties as a result of its use. There may occasionally be unintentional errors on this publication. ORing reserves the right to revise the contents of this publication without notice.
CONTACT INFORMATION
ORing Industrial Networking Corp.
3F., NO.542-2, Jhongjheng Rd., Sindian District, New Taipei City 231, Taiwan, R.O.C. Tel: + 886 2 2218 1066 // Fax: + 886 2 2218 1014 Website: www.oring-networking.com
Technical Support
Sales Contact
E-mail: [email protected] (Headquarters)
Page 3
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
2
Table of Content
Getting Started .................................................................................................................... 4
1.1 About the RDS-3086/3166G ................................................................................. 4
1.2 Software Features ................................................................ ................................ 4
1.3 Hardware Specifications ....................................................................................... 4
Hardware Overview ............................................................................................................. 5
2.1 Back Panel ........................................................................................................... 5
2.1.1 Ports and Connectors ....................................................................................... 5
2.2 Front Panel ........................................................................................................... 5
2.2.1 LED .................................................................................................................. 6
Hardware Installation .......................................................................................................... 7
3.1 Rack-mount Installation ........................................................................................ 7
3.2 Wiring ................................................................................................................... 8
3.2.1 Power Inputs ................................................................................................ .... 8
3.3 Connection ........................................................................................................... 8
3.3.1 Ethernet Port Pin Assignment ........................................................................... 8
3.3.2 SFP ................................................................................................................ 10
3.3.3 Serial Port Pin Assignment ............................................................................. 10
3.3.4 Console Port Pin Assignment.......................................................................... 11
Management ...................................................................................................................... 12
4.1 DS-Tool .............................................................................................................. 12
4.1.1 Install DS-Tool ................................................................................................ 12
4.1.2 Using DS-Tool ................................................................................................ 13
4.1.3 Configure Device Servers ............................................................................... 14
4.1.3.1 General .................................................................................................... 14
4.1.3.2 Networking ............................................................................................... 15
4.1.3.3 Upgrade Firmware .................................................................................... 16
4.1.3.4 Save/Load ................................................................................................ 16
4.1.4 Configure Serial Port ...................................................................................... 17
4.1.4.1 Serial Settings ...................................................................................................... 17
4.1.4.2 Service Mode ....................................................................................................... 20
4.2 Web Management ................................................................ .............................. 25
4.2.1 Basic Settings................................................................................................. 26
4.2.1.1 ........................................................................................................................... LAN
Page 4
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
3
........................................................................................................................................... 26
4.2.2 Serial Setting .................................................................................................. 28
4.2.2.1 Serial Configuration .................................................................................. 28
4.2.2.2 Port Profile ................................................................................................ 30
4.2.2.3 Service Mode............................................................................................ 30
4.2.3 System Tools .................................................................................................. 37
4.2.3.1 Login Setting............................................................................................. 37
4.2.3.2 Date & Time ................................................................ .............................. 37
4.2.3.3 Device Restart .......................................................................................... 38
4.2.3.4 Firmware Upgrade .................................................................................... 38
4.2.3.5 Save/Restore Configurations .................................................................... 39
4.2.3.6 Miscellaneous ........................................................................................... 40
4.2.4 System Status ................................................................................................ 40
4.2.4.1 System Info ........................................................................................................ 40
Page 5
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
4
Getting Started
1.1 About the RDS-3086/3166G
The RDS-3086/3166G is a RS-232/422/485-to-LAN device server with 8 or 16 serial ports and 6 Ethernet ports. Besides standard features such TCP/IP interface and versatile operation mode support (Virtual Com, Serial Tunnel, TCP Server, TCP Client, and UDP), the device can be managed using the Windows untility, DS-Tool, which allows you to configure multiple devices and set up the mappings of Virtual Com. I addition, the device can simultaneously transfer data to up to five redundant host PCs to aovid Ethernet connection breakdown or any host PC failure. The device provides 4x10/100/1000Base-T(X) Ethernet ports and 2x100/1000Base-X SFP ports to meet demand for high bandwidth and long distance transmission. With a wide operating temperature from -40 oC to 70oC, the device is ideal for harsh industrial environments.
1.2 Software Features
Redundant multiple host devices including Virtual COM, TCP Server, TCP Client modes
and four IP ranges
Supports multiple operating modes such as Virtual Com, Serial Tunnel, TCP Server, TCP
Client, UDP
NAT-pass through support  Event warning by Syslog, Email, and SNMP trap  Configurable by Web Interface  Various Windows O.S. supported: Windows NT/2000/ XP/ 2003/VISTA(32/64bit)/
Windows 7(32/64bit)
1.3 Hardware Specifications
4 x 10/100/1000Base-T(X) Ethernet ports  2 x 100/1000Base-X SFP ports  8 or 16 x serial ports  1 x consol port  100-240VAC power supply  Operating Temperature: -10 to 70oC  Storage Temperature: -40 to 85oC  Operating Humidity: 5% to 95%, non-condensing  Dimensions: 443.7 (W) x 201 (D) x 45 (H) mm
Page 6
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
5
Hardware Overview
2.1 Back Panel
2.1.1 Ports and Connectors
The device provides the following ports on the back panel, including four RJ -45 Ethernet ports, two SFP ports, and sixteen RJ48 serial ports
Port
Description
LAN slots
4 x 10/100/1000Base-T(X) ports
SFP port
2 x 100/1000Base-T(X) ports
Serial port
16 x RS-232/422/485 ports
Power connector
1 x 100-240VAC with power socket
2.2 Front Panel
1. Serial ports
2. RJ-45 Ethernet LAN ports
3. SFP ports
4. Power socket
5. LNK/ACT LED for Ethernet LAN ports
6. Speed LED for Ethernet LAN ports
Page 7
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
6
1. Link/Act LED for serial ports
2. Link/Act LED for Gigabit ports
3. Faulty relay LED
2.2.1 LED
LED
Color
Status
Description
PWR
Green
On
Power module is on
ETH LNK/ACT
Green On
Port is running at 1000Mbps
Blinking
Transmitting data
Amber
On
Port is running at 10/100Mbps.
Speed
Green
On
Port is running at 1000Mbps
Amber
On
Port is running at 100Mbps
Green/Amber
Off
Port is running at 10Mbps
Serial TX / RX
Amber
On
Port is receiving data
Green
On
Port is transmitting data
4. Console port
5. Power indicator
6. Reset button
Page 8
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
7
Hardware Installation
3.1 Rack-mount Installation
The device comes with two rack-mount kits to allow you to fasten the device to a rack in any environments.
Rack-mount Kit Measurement (unit = mm)
Follow the following steps to install the device to a rack.
Step 1: Install left and right front mounting brackets to the device using 4 screws on each side. Step 2: With front brackets orientated in front of the rack, fasten the brackets to the rack using
two more screws. Note: You can install the brackets on both sides at back of the device and mount it to the rack with the rear panel facing outward if the space for front panel cabling is limited. Remember, when installing the brackets on the front sides, use the four screw holes at the top and bottom. When installing the brackets on the back sides, use the four screw holes at the top and middle.
Page 9
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
8
3.2 Wiring
3.2.1 Power Inputs
The device is powered by AC power. Simply insert the AC power cable to the power connector at the back of the device and turn on the power switch. The input voltage is 100V~240V / 50~60Hz.
3.3 Connection
3.3.1 Ethernet Port Pin Assignment
The device is equipped with standard Ethernet ports. According to the link type, the device uses CAT 3, 4, 5,5e UTP cables to connect to any other network devices (PCs, servers, switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications:
Cable
Type
Max. Length
Connector
10BASE-T
Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft)
RJ-45
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
RJ-45
ATTENTION
1. Be sure to disconnect the power cord before installing and/or wiring your devices.
2. Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.
3. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
4. Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
5. Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
6. You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring sharing similar electrical characteristics can be bundled together
7. You should separate input wiring from output wiring
8. It is advised to label the wiring to all devices in the system
WARNING
Do not disconnect modules or wires unless power has been switched off or the area is known to be non-hazardous. The devices may only be connected to the supply voltage shown on the type plate.
Page 10
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
9
1000BASE-T
Cat. 5/Cat. 5e 100-ohm UTP
UTP 100 m (328ft)
RJ-45
With 10/100Base-T(X) cables, pins 1 and 2 are used for transmitting data, and pins 3 and 6 are used for receiving data.
10/100Base-T(X) RJ-45 Port Pin Assignments:
Pin Number
Assignment
1
TD+
2
TD-
3
RD+
6
RD-
1000Base-T RJ-45 Port Pin Assignments:
Pin Number
Assignment
1
BI_DA+
2
BI_DA-
3
BI_DB+
4
BI_DC+
5
BI_DC-
6
BI_DB-
7
BI_DD+
8
BI_DD-
The device supports auto MDI/MDI-X operation. You can use a cable to connect the device to a PC. The table below shows the 10/100Base-T(X) MDI and MDI-X port pin outs.
10/100Base-T(X) MDI/MDI-X Pin Assignments:
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
Page 11
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
10
1000Base-T MDI/MDI-X Pin Assignments:
Pin Number
MDI port
MDI-X port
1
BI_DA+
BI_DB+
2
BI_DA-
BI_DB-
3
BI_DB+
BI_DA+
4
BI_DC+
BI_DD+
5
BI_DC-
BI_DD-
6
BI_DB-
BI_DA-
7
BI_DD+
BI_DC+
8
BI_DD-
BI_DC-
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
3.3.2 SFP
The device comes with SFP ports that can connect to other devices using SFP modules. The SFP modules are hot-swappable input/output devices that can be plugged into the SFP ports to connect the device with the fiber-optic network. Remember that the TX port of Device A should be connected to the RX port of Device B.
1. Insert clean dust plugs into the SFPs after the cables are extracted from them.
2. Clean the optic surfaces of the fiber cables before you plug them back into the optical bores of another SFP module.
3. Avoid getting dust and other contaminants into the optical bores of your SFP modules in cases of malfunction.
3.3.3 Serial Port Pin Assignment
The device provides serial ports in RJ48 connector type. Please refer to the following table for pin assignment.
Fiber cord
Page 12
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
11
3.3.4 Console Port Pin Assignment
The device provides a console port in RJ45 connector type for device management. You can connect the port to a PC via the RS-232 cable with a DB-9 female connector. The DB-9 female connector of the RS-232 cable should be connected the PC while the other end of the cable (RJ-45 connector) should be connected to the console port of the device server.
PC pin out (male) assignment
RS-232 with DB9 female connector
DB9 to RJ 45
Pin #2 RD
Pin #2 TD
Pin #2
Pin #3 TD
Pin #3 RD
Pin #3
Pin #5 GD
Pin #5 GD
Pin #5
Pin #
RS-232
RS-422
RS-485 (4 wire )
RS-485 (2 wire )
1
NC
NC
NC
NC 2 DCD
TXD -
TXD -
DATA-
3
RXD
TXD +
TXD +
DATA+
4
TXD
RXD +
RXD +
5
DTR
RXD -
RXD -
6 GND
GND
GND
7 DSR
8 RTS 9
CTS 10
RI RS 232 mod act as DTE
Page 13
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
12
Management
4.1 DS-Tool
The Windows utility DS-Tool is a powerful Windows utility for DS series. It supports device discovery, device configuration, group setup, group firmware update, and monitoring functions. The tool enables you to easily install and configure devices on the network.
4.1.1 Install DS-Tool
Follow the steps below to install the tool.
Step 1: Run the Setup program by clicking Start after selecting the folder for DS-Tool.
Page 14
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
13
Step 2: When installation completes successfully, click OK.
Step 3: You can launch the tool right immediately by checking Launch DS-Tool Now or launch it later by checking Launch DS-Tool Later.
4.1.2 Using DS-Tool Explore device servers
DS-Tool will broadcast to the network and search all available DS devices in the network automatically. The default IP address of the device is “192.168.10.2”. Select the device you wish to use and press Add button.
You can set a static IP address or use the DHCP client mode to acquire an IP address automatically. Click OK and the device will be added.
Page 15
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
14
4.1.3 Configure Device Servers
4.1.3.1 General
This page enables you to perform general configuration for the device, includes the device name, SNTP server, and auto IP report.
Page 16
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
15
Label
Description
Device Name/Location
You can input the device name or related information in this field. By clicking Locate On, you can locate the serial server’s position.
Using SNTP Time Server
If you want to set the time via a SNTP time server, check the box and input related information such as the SNTP server domain name or IP address and the port number, and select a time zone.
Auto IP Report
Check the Auto IP Report box if you want to receive IP report regularly. By Clicking the Get Current Host, you will get your local IP address. Input a value in the Report Interval time based on how often you want the device server to report its status.
4.1.3.2 Networking
You must assign a valid IP address for the device before attaching it in your network environment. Your network administrator should provide you the IP address and related settings. The IP address must be unique within the network (otherwise, DS will not have a valid connection to the network). You can choose from three possible “IP configuration” modes: Static, DHCP/BOOTP. The factory default IP address is “192.168.10.2”
Label
Description
Using Static IP
Manually assign an IP address to the device.
Using DHCP/BOOTP
Check this box to have the IP address automatically assigned by a DHCP server in your network.
IP Address
Enter the IP address of the device
Page 17
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
16
Netmask
All devices on the network must have the same subnet mask to communicate on the network.
Gateway
Enter the IP address of the router in you network.
DNS1/2
Enter the IP addresses of the primary and secondary DNS servers, The DNS server translates domain names into IP address.
4.1.3.3 Upgrade Firmware
You can find up-to-date firmware from ORing’s website. To update firmware for the device, save the firmware file in your host PC, and then specify the file location by clicking on the Browsing button and continue operation by pressing Update.
4.1.3.4 Save/Load
This page allows you to save the current configuration file to any local drive or any network drive to which your management computer can connect.
Label
Description
Apply and Save
Click this button will save all applied settings into the flash of the appliance
Load Default
All parameters changes to factory’s default except network
Page 18
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
17
settings. If you want to load all factory default, you need to press
Reset button on the device (Hardware restore).
Reboot Device
Click this button will reboot device and need to broadcast again in order to search the device (warm start).
Import Configuration
Click this button will retrieve saved configuration file and apply it to in current device
Export Configuration
Saving the current parameters to a file and export it to a current host.
4.1.4 Configure Serial Port
You can configure the settings for each serial port by clicking on the port number in the left panel of the window. Once you click on a port, the following screen will show up in the right panel.
4.1.4.1 Serial Settings
The page allows you to configure serial parameters, serial communication modes, data packing options, and event notifications.
Page 19
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
18
Label
Description
Port Alias
Port alias enables the device server to easily identify the serial devices connected to it. Enter an identifying name to be identified by the connected device.
Baud rate
Baud rate is the rate at which data is transferred over a serial link. When setting the baud rate to 9600bps, the serial port will transfer a maximum of 9600 bits per second. You can select a baud rate from the drop-down list which ranges from 110bps to 460800bps
Parity
Parity is a simple form of error detection which guards data on the cable between the connected devices and the serial port. Available options include: None: parity checking is not performed and the parity bit is not transmitted. Odd: the number of mark bits in the data is counted, and the parity bit is asserted or unasserted to obtain an odd number of mark bits. Even: the number of mark bits in the data is counted, and the parity bit is asserted or unasserted to obtain an even number of
Page 20
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
19
mark bits. Mark: the parity bit is always set to the mark signal condition (logical 1)
Space: the last transmitted data bit will always be a logical 0
Data Bits
Choose the number of data bits to transmit. You can configure data bits to be 5, 6, 7, or 8. Data is transmitted as a series of five, six, seven, or eight bits (five and six bit data formats are used rarely for specialized communications equipment).
Stop Bits
Choose the number of bits used to indicate the end of a byte. You can configure stop bits to be 1 or 2(1.5). If Stop Bits is 1.5, the stop bit is transferred for 150% of the normal time used to transfer one bit. Both the computer and the peripheral device must be configured to transmit the same number of stop bits.
Flow Control
Serial communication consists of hardware flow control and software flow control, so called as the control is handled by software or hardware. XOFF and OXN is software flow control while RTS/CTS or DTR/DSR is hardware flow control. Choose XOFF to tell the computer to stop sending data; then the receiving side will send an XOFF character over its Tx line to tell the transmitting side to stop transmitting. Choose XON to tell the computer to begin sending data again; then the receiving side will send an XON character over its Tx line to tell the transmitting side to resume transmitting. In hardware flow control mode, when the device is ready to receive data, it sends a CTS (Clear To Send) signal to the device on the other end. When a device has something it wants to send, it will send a RTS (Ready To Send) signal and waits for a CTS signal to come back its way. These signals are sent apart from the data itself on separate wires.
Interface
Choose an interface for your serial device. Available interfaces include RS-232, RS-422, RS-485(2-wires), and
RS-485(4-wires),
Performance
Throughput: guarantees highest transmission speed. Latency: guarantees shortest response time.
Delimiter Settings
Serial to Ethernet / Ethernet to Serial
For advanced data packing options, you can specify
Page 21
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
20
delimiters for Serial to Ethernet and / or Ethernet to Serial communications. You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be hold until the delimiters are received or the option. Flush Serial to Ethernet data buffer times out. 0 means disable. Factory default is 0.
Flush Data Buffer After:
The received data will be queuing in the buffer until all the delimiters are matched. When the buffer is full (4K Bytes) or after "flush S2E data buffer" timeout the data will also be sent. You can set the time from 0 to 65535 seconds.
Force TX Interval Time
Force TX interval time is to specify the timeout when no data has been transmitted. When the timeout is reached or TX buffer is full (4K Bytes), the queued data will be sent. 0 means disable. Factory default value is 0.
4.1.4.2 Service Mode
Virtual COM Mode
In Virtual COM Mode, the driver establishes a transparent connection between host and serial device by mapping the port of the serial server serial port to a local COM port on the host computer. Virtual COM Mode also supports up to 5 simultaneous connections, so that multiple hosts can send or receive data by the same serial device at the same time.
Page 22
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
21
Label
Description
Data Port
Set the port number for data transmission.
Idle Timeout
When a serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts. 0 means the function is disabled which is also the factory default value. If multilink is configured, only the first host connection is effective for this setting.
Alive Check
The serial device will send a TCP alive-check package in each defined time interval (Alive Check) to remote host to check the the status of TCP connections. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 means the function is disabled which is also the factory default value.
Max Connection
The number of max connections can be supported simultaneously is 5; default values is 1.
Map Virtual COM
Select a Virtual COM name to map on.
Page 23
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
22
TCP Server Mode
In TCP Server mode, the serial port on the device server is assigned a unique port number. The host computer initiates contact with the device server, establishes the connection, and receives data from the serial device. Five simultaneous connections are supported in this mode, enabling multiple hosts to collect data from the same serial device at the same time.
Label
Description
Data Port
Set the port number for data transmission.
Auto Scan
Scan the data port automatically.
Idle Timeout
When a serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts. 0 means the function is disabled which is the factory default value. If multilink is configured, only the first host connection is effective for this setting.
Alive Check
The serial device will send a TCP alive-check package in each defined time interval (Alive Check) to remote host to check the TCP connection. If the TCP connection is not alive, the
Page 24
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
23
connection will be closed and the port will be freed. 0 means the function is disabled which is the factory default value.
Max Connection
The number of maximum connections can be support simultaneously is 5; default values is 1.
Destination Host
Input the IP address of the host.
TCP Client Mode
In TCP Client mode, the device can establish a TCP connection with the server by the method you have settled (Startup or any character). After the data has been transferred, the device can disconnect automatically from the server by using the TCP alive check time or idle time settings.
Label
Description
Destination Host
Input the IP address of the host.
Port
Set the port number of data port.
Idle Timeout
When a serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts. 0 means the function is disabled which is the factory default value. If multilink is configured, only the first host connection is effective for this setting.
Page 25
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
24
Alive Check
The serial device will send a TCP alive-check package in each defined time interval (Alive Check) to remote host to check the TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 means the function is disabled which is the factory default value.
Connect on Startup
The TCP Client will build a TCP connection once the connected serial device is started.
Connect on Any Character
The TCP Client will build a TCP connection once the connected serial device starts to send data.
UDP Mode
Compared to TCP communication, UDP is faster and more efficient as you can unicast or multicast data from the serial device server to host computers, and the serial device can also receive data from one or multiple host.
Label
Description
Listening Port
IP port for listening incoming messages
Destination Host Begin / End
If there are more than one destination hosts, specify the IP address range by inputting a value in destination host IP begin / end fields. You can also auto scan the sending port number of the device
Sending Port
IP port for sending outgoing messages
Page 26
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
25
For Modbus mode settings, please refer to the next section.
4.2 Web Management
The device can be managed via a built-in web server which supports Internet Explorer (Internet Explorer 5.0 or above versions) and other Web browsers such as Chrome. Therefore, you can manage and configure the device easily and remotely. You can also upgrade firmware via a Web browser. The Web management function not only reduces network bandwidth consumption, but also enhances access speed and provides a user-friendly viewing screen.
Note: By default, IE5.0 or later version do not allow Java applets to open sockets. You need to modify the browser setting separately in order to enable Java applets for network ports.
Management via Web Browser
Follow the steps below to manage your device via a Web browser
System Login
1. Launch an Internet Explorer.
2. Type http:// and the IP address of the device. By default, this is 192.168.10.2. Then press Enter.
3. A login screen appears.
4. Log in with the default user name “admin”. By default, no password is required; however, you can set up a password later in the management page.
5. Press Enter or click OK, the management page appears.
Page 27
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
26
Note: you can use the following default values: IP Address: 192.168.10.1 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.10.254 User Name: admin
After logging in, you will see the information of the device as below.
On the left hand side of the management interface shows links to various settings. Clicking on the links will bring you to individual configuration pages.
4.2.1 Basic Settings
4.2.1.1 LAN
This page allows you to configure the IP settings of the LAN for the device. The LAN IP
Page 28
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
27
address is private to your internal network and is not visible to Internet.
Label
Description
Device Name
Enter the name of your device
Protocol
Choose to use static or DHCP protocols. Choose DHCP if your ISP dynamically assigns an IP address on connection. Choose static if the ISP provides you with a static (permanent) IP address and does not assign it dynamically. You need to set up IP address, subnet mask, and gateway information from your ISP.
IP Address
The IP address of the LAN. The default value is 192.168.10.1
Subnet Mask
The subnet mask of the LAN. The default value is
255.255.255.0
Gateway
Enter the IP address of default gateway.
DNS Server 1/2
Enter a valid IP address of the primary DNS server and a valid
Page 29
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
28
IP address of the secondary DNS server.
G5/G6 SFP Speed
Select a speed for the SFP port.
4.2.2 Serial Setting
4.2.2.1 Serial Configuration
This page allows you to configure serial port parameters.
Label
Description
Port Alias
Enter the COM port number that modem is connected to
Interface
Choose an interface for your serial device. Available interfaces include RS-232, RS-422, RS-485-2W, and RS-485-4W.
Baud Rate
Choose a baud rate in the range between 110 bps and 11520 bps
Data Bits
Choose the number of data bits to transmit. You can configure data bits to be 5, 6, 7, or 8. Data is transmitted as a series of five, six, seven, or eight bits (five and six bit data formats are used rarely for specialized communications equipment).
Page 30
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
29
Stop Bits
Choose the number of bits used to indicate the end of a byte. You can configure stop bits to be 1 or 1.5(2). If Stop Bits is 1.5, the stop bit is transferred for 150% of the normal time used to transfer one bit. Both the computer and the peripheral device must be configured to transmit the same number of stop bits.
Parity
Chose the method of detecting errors in transmission. Parity control bit modes include None, Odd, Even, Mark, and Space. None: parity checking is not performed and the parity bit is not transmitted. None is the most common parity setting with error detection handled by a communication protocol. Odd: the last data bit transmitted will be a logical 1 if the data transmitted had an odd amount of 0 bits Even: the last data bit transmitted will be a logical 1 if the data transmitted had an even amount of 0 bits. Mark: the parity bit is always set to the mark signal condition (logical 1)
Space: the last transmitted data bit will always be a logical 0
Flow Control
Serial communication consists of hardware flow control and software flow control, so called as the control is handled by software or hardware. XOFF and OXN is software flow control while RTS/CTS or DTR/DSR is hardware flow control. Choose XOFF to tell the computer to stop sending data; then the receiving side will send an XOFF character over its Tx line to tell the transmitting side to stop transmitting. Choose XON to tell the computer to begin sending data again; then the receiving side will send an XON character over its Tx line to tell the transmitting side to resume transmitting. In hardware flow control mode, when the device is ready to receive data, it sends a CTS (Clear To Send) signal to the device on the other end. When a device has something it wants to send, it will send a RTS (Ready To Send) signal and waits for a CTS signal to come back its way. These signals are sent apart from the data itself on separate wires.
Force TX Interval Time
This setting will specify the timeout when no data has been transmitted. When the timeout is reached or TX buffer is full (4K Bytes), the queued data will be sent. 0 means disable. Factory default value is 0.
Page 31
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
30
Performance
Throughput: This mode is optimized for the highest
transmission speed.
Latency: This mode is optimized for the shortest response time.
4.2.2.2 Port Profile
Label
Description
Local TCP Port
Indicates the TCP port the device uses to listen to connections, and that other devices must use to contact the device. To avoid conflicts with well-known TCP ports, the default is set to 4000.
Command Port
Indicates the listen TCP port for IP-Serial Lib commands from the host. In order to prevent a TCP port conflict with other applications, the user can set the Command port to another port if needed.
Flush Data Buffer After
The received data will be queuing in the buffer until all the delimiters are matched. When the buffer is full (4K Bytes) or after “Flush Data Buffer After” times out the data will also be sent. You can set the time from 0 to 65535 seconds.
Delimiter
For advanced data packing options, you can specify delimiters for Serial to Ethernet and / or Ethernet to Serial communications. You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be hold until the delimiters are received or the option Flush Serial to Ethernet data
buffer times out. 0 means disable. Factory default is 0.
4.2.2.3 Service Mode
Virtual COM Mode
Page 32
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
31
In Virtual COM mode, the driver establishes a transparent connection between the host and the serial device by mapping the port of the serial server to a local COM port on the host computer. Virtual COM mode also supports up to 5 simultaneous connections, so that multiple hosts can send or receive data by the same serial device at the same time.
Label
Description
Data Encryption
Click Enable and the data will be encrypted with SSL.
Idle Timeout
When serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts. 0 indicate disable this function. Factory default value is 0. If Multilink is configured, only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check package in each defined time interval (Alive Check) to remote host to check the TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate disable this function. Factory default is 0.
Max Connection
The number of maximum connections can be supported. The maximum value is 5, default values is 1.
*Not allowed to mapping Virtual COM from web
TCP Server Mode
In TCP Server mode, IMG is configured with a unique port combination on a TCP/IP network. In this case, IMG waits passively to be contacted by the device. After the device establishes a connection with the serial device, it can then proceed with data transmission. The TCP Server mode also supports up to 5 simultaneous connections, so that multiple device can receive data from the same serial device at the same time.
Page 33
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
32
Label
Description
Data Encryption
Click Enable and the data will be encrypted with SSL.
TCP Server Port
Set the port number for data transmission.
Idle Timeout
When serial port stops data transmission for a defined period of time (Idle Timeout), the connection will be closed and the port will be freed and try to connect with other hosts. 0 indicate disable this function. Factory default value is 0. If Multilink is configured, only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check package in each defined time interval (Alive Check) to remote host to check the TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate disable this function. Factory default is 0.
Max Connection
The number of maximum connections can be supported. The maximum value is 5, default values is 1.
TCP Client Mode
In TCP Client Mode, the device can establish a TCP connection with the server by the method you set (Startup or any character). After the data has been transferred, the device can disconnect automatically from the server by using the TCP alive check time or idle timeout settings.
Page 34
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
33
Label
Description
Destination Host
Set the IP address of host and the port number of data port. .
Idle Timeout
When serial port stops data transmission for a defined period of time, the connection will be closed and the port will be freed and try to connect with other hosts. 0 indicates disable this function. Factory default value is 0. If multilink is configured, only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check packages in each defined time interval to remote host to check the TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate disable this function. Factory default is 0.
Connect
Startup: the TCP Client will build TCP connection once the
connected serial device is started. Any Character: the TCP Client will build TCP connection once the connected serial device starts to send data.
UDP Mode
Compared to TCP communications, UDP is faster and more efficient. In UDP mode, you can uni-cast or multi-cast data from the serial device server to host computers, and the serial device can also receive data from one or multiple host.
Page 35
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
34
Label
Description
Listen Port
Allows the user to set a new TCP port number to listen on rather than the default value of the device
Host Start/End IP
If there are more than one destination hosts, specify the IP address range by inputting a value in Host Start / End IP. You can also auto scan the sending port number of the device
Send Port
Set the send port number.
Modbus RTU Slave Mode
The Modbus RTU Slave mode allows communications between a host computer and a slave device. After a host computer sends a command, the slave device processes the command and returns a response to the host computer. This process is repeated, allowing the host computer to monitor and control controller operation.
Label
Description
TCP Server Port
Indicates the port used for the Modbus/TCP communication
Max Connection
The total number of remote TCP/IP clients allowed to connect to this server.
Page 36
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
35
Max Try Time
The maximum number of request retries performed serially.
Request Pause
The delay between serial requests in milliseconds
Response Wait
The serial response timeout in milliseconds
Idle Timeout
Enter a TCP connection timeout in seconds. When no Modbus/TCP data is received within this timeout, the TCP connection will be dropped.
Modbus RTU Master Mode
The ModBus RTU Master mode is used to connect to the serial device which runs as RTU slave. Serial port server will connect to the remote TCP Server, which is also called Modbus TCP Slave.
Label
Description
Destination Host
Set the IP address of host and the port number of data port. .
Idle Timeout
When serial port stops data transmission for a defined period of time, the connection will be closed and the port will be freed and try to connect with other hosts. 0 indicate disable this function and is also the factory default value. If multilink is configured, only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check packages in each defined time interval to remote host to check the TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate disable this function. Factory default is 0.
Modbus ASCII Slave Mode
Modbus ASCII Slave mode works the same as Modbus/RTU Slave mode, except that the data format is Modbus/ASCII.
Page 37
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
36
Label
Description
TCP Server Port
Indicates the port used for the Modbus/TCP communication
Max Connection
The total number of remote TCP/IP clients allowed to connect to this server.
Max Try Time
The maximum number of request retries performed serially.
Request Pause
The delay between serial requests in milliseconds
Response Wait
The serial response timeout in milliseconds
Idle Timeout
Enter a TCP connection timeout in seconds. When no Modbus/TCP data is received within this timeout, the TCP connection will be dropped.
Modbus ASCII Master Mode
Label
Description
Destination Host
Set the IP address of host and the port number of data port. .
Idle Timeout
When serial port stops data transmission for a defined period of time, the connection will be closed and the port will be freed and try to connect with other hosts. 0 indicate disable this function. Factory default value is 0. If Multilink is configured,
Page 38
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
37
only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check packages in each defined time interval to remote host to check the TCP connection. If the TCP connection is not alive, the connection will be closed and the port will be freed. 0 indicate disable this function. Factory default is 0.
4.2.3 System Tools
4.2.3.1 Login Setting
Label
Description
Login Name
This field shows the current login username.
Old Password
Enter the password you currently use to login the system if any.
New Password
Enter a new login password. Acceptable characters of this field contains '0-9', 'a-z', 'A-Z' and must be between 0 and 15 characters in length.
Confirm New Password
Retype the new password for confirmation. Acceptable inputs of this field contains '0-9', 'a-z', 'A-Z' and must be between 0 and 15 characters in length.
4.2.3.2 Date & Time
In this page, you can set the date & time of the device. A correct date and time will help the system log events. You can set up a NTP (Network Time Protocol) client to synchronize date & time with a NTP server on the Internet.
Page 39
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
38
Label
Description
NTP
Enables or disables NTP function
NTP Server 1
The primary NTP server
Port
Enter the port name
Time Zone
Select the time zone you are located in
4.2.3.3 Device Restart
This page allows you to configure restart settings for the device.
Label
Description
Restart Now
Click to restart the device via warm reset
4.2.3.4 Firmware Upgrade
ORing launches new firmware constantly to enhance device performance and functions. To upgrade firmware, download new firmware from ORing’s website to your PC and install it via Web upgrade. Make sure the firmware file matches the model of your device. It will take several minutes to upload and update the firmware. After upgrade completes successfully, reboot the device.
Page 40
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
39
During firmware upgrading, do not turn off the power of the device or press the reset button.
4.2.3.5 Save/Restore Configurations
This page allows you to save configurations or return settings to previous status. You can download the configuration file from the Web. Note: users using old versions of Internet Explorer may have to click on the warning on top of the browser and choose Download File.
Label
Description
Save
Click to save existing configurations as a file for future usage.
Page 41
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
40
Restore Mode
You can restore configurations to previous status by installing a previous configuration file. To do this, choose Web Restore or Tftp Restore. If you choose Web Restore, you need to choose a file and click Web Restore. If you select Tftp Restore, fill in a Tftp server IP address and the file name before clicking Tftp Restore.
Restore Factory Default Setting
Click to reset the device to the factory settings. The device will reboot to validate the default settings.
4.2.3.6 Miscellaneous
This page enables you to run ping test which will send out ping packets to test if a computer is on the Internet or if the WAN connection is OK. Enter a domain name or IP address in the destination box and click Ping to test.
4.2.4 System Status
4.2.4.1 System Info
This page displays the detailed information of the device including model name, description, firmware version, WAN, LAN and wireless settings.
Page 42
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
41
Technical Specifications
ORing Device Server
Model
RDS-3166G
RDS-3086G
Physical Ports
10/100/1000Base-T(X) Ports in
RJ45
Auto MDI/MDIX
4
100/1000Base-X with SFP port
2
RS-232 Serial Console Port
RS-232 in RJ45 connector with console cable. 115200bps, 8, N, 1
Serial Ports
Connector (10-pin RJ48)
RJ48 x 16
RJ48 x 8
Operation Mode
RS-232/422/485
Serial Baud Rate
50 bps to 921.6 Kbps
Data Bits
7, 8
Parity
odd, even, none, mark, space
Stop Bits
1, 1.5, 2
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND
Flow Control
XON/XOFF, RTS/CTS, DTR/DSR
Network Protocol
Protocol
ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS,
SNMP V1/V2c, HTTPS
ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS,
SNMP V1/V2c, HTTPS, SMTP, DDNS, PPPoE
LED indicators
Power indicator
Green On: Power is on
10/100/1000Base-T(X) RJ45 port
indicator
Green for Link/Act indicator.
Dual color LED for speed indicator : Green for 1000Mbps, Amber for 100Mbps, Off for 10Mbps
LED Display System (Front panel)
Serial TX / RX LEDs: Green for Serial port transmitting data,
Amber for Serial port receiving data
G1~G6 : Green for port Link/Act
Fault : indicate unexpected event occurred
Power
Power Input
100-240VAC with power socket
Power consumption (Typ.)
14.4 watts.
13.4 Watts
Overload current protection
Present
Physical Characteristic
Dimension (W x D x H)
443.7 (W) x 211.5 (D) x 44 (H) mm
Weight (g)
2891 g
Environmental
Storage Temperature
-40 to 85oC (-40 to 185oF)
Operating Temperature
-40 to 70oC (-40 to 158oF)
Operating Humidity
5% to 95% Non-condensing
Regulatory approvals
EMI
FCC Part 15, CISPR (EN55022) class A, EN50155 (EN50121-3-2, EN55011, EN50121-4)
EMS
EN61000-4-2 (ESD)
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
Page 43
RDS-3086/3166G User Manual
ORing Industrial Networking Corp
42
EN61000-4-8,
EN61000-4-11
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
Safety
EN60950-1
Warranty
5 years