ORiNG IGS-9084GP-FB2 Quick Installation Manual

Page 1
IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
G7
G5
G3
G1
Quick InstallationGuide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
The series isa managed industrialEthernet switch with eight 10/100/1000Base-T(X)ports and four100/1000Base-X SFP ports.With fiber opticalbypass design, theswitch can ensurecontinued network operation whenany inline deviceon the networkfails. The switchsupports Ethernet Redundancyprotocol, O-Ring (recoverytime < 30msover 250 units of connection)and MSTP (RSTP/STPcompatible) to protectmission-critical applications fromnetwork interruptions ortemporary malfunctions withfast recovery technology. Witha wide operatingtemperature from -40 Cto 70 C, the devicecan be managedcentrally via ORing’sproprietary Open-Vision management utiltyas well asvia Web-based interfaces,Telnet, andconsole (CLI). Theswitch is oneof the mostreliable choices forhighly-managed and fiber Ethernetapplications.
IGS-9084GP-FB2
oo
Preparation
Before youbegin installing theswitch, make sureyou have allof the package contents availableand a PCwith Microsoft InternetExplorer 6.0 orlater, for using web-basedsystem management tools.
Elevated OperatingAmbient:
ReducedAir Flow:
Mechanical Loading:
If installed in a closed or multi-unit rack assembly,the operating ambienttemperature of therack environment maybe greater thanroom ambient. Therefore,consideration should begiven to installing theequipment in anenvironment compatible withthe maximum ambient temperature(Tma) specified bythe manufacturer.
Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Safety & Warnings
Dimension
Panel Layouts
7
1. PowerLED
2. PWR1LED
3. PWR2LED
4. R.M.status LED
5. Ringstatus LED
6. Faultyrelay indicator
7. SFPport
8. Link/actionLED for Gigabit Ethernetports
Package Contents
Contents
DIN-rail Kit
CD
IGS-9084GP-FB2
Pictures Number
X1
X1
X1
Front View
TopPanel
The device is shippedwith the followingitems. If anyof these itemsis missing ordamaged, please contactyour customer servicerepresentative for assistance.
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
QIG
Console Cable
X2
X1
X1
Wall-mountKit
33.0
30.0
12.5
105.5
10.9
15.0
70.5
154.0
96.4
87.0
48.0
17.5
94.0
124.0
48.0
58.0
7.50
R2.5
R3.95
80.5
62.0
87.9
10
14
1 2 3 4 5 6
Rear View
1
2
PWR-1PWR-2
1A@24V
DC48V
V2-V2+ V1-V1+
Fault
1
1. Wall-mountscrew holes
2. Din-railscrew holes
2
1. Terminalblocks: PWR1, PWR2 (12-48V DC),Relay
2. Groundwire.
1
Installation
Step 1:
Step 2:
Slant the switch and screwthe Din-railkit onto theback of theswitch, right in the
middle of the back panel.
Slide theswitch ontoa DIN-rail fromthe Din-rail kitand make surethe switch clicks
into therail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the twopieces of wall-mount kits onto bothends of the rear panel ofthe
switch. A total of six screws are required,as shown below.
Use the switch,with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Insert a screwhead through the large parts ofthe keyhole-shaped apertures,
and then slidethe switch downwards. Tighten thescrews for added stability.
Wall-mounting
QIG
1907-2-29-IGS9084GPFB2-1.0
Circuit Overloading:Consideration should begiven to theconnection of theequipment to the
supply circuitand the effectthat overloading ofthe circuits mighthave on overcurrentprotection and supplywiring. Appropriateconsideration of equipmentnameplate ratings shouldbe used when addressingthis concern.
11
8
9
Network Connection
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
9. DuplexLED for Gigabit Ethernet ports
10. GigabitEthernet ports
11. Link/actionLED for SFPport
12. Bypassnetwork port
13. Bypassmonitor port
14. Consoleport
15. Resetbutton
12
13
IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
The switchprovides standard Ethernet ports. According to the link type, the switch uses CAT 3,4, 5, 5e UTP cables to connect to any other network devices (PCs, servers, switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable Typesand Specifications:
Cable Type Max. Length Conne ctor
10BASE-T Cat. 3, 4,5 100-ohm UTP 100m (328 ft) RJ-45
100BASE-TX Cat. 5100-ohmUTP UTP 100m(328 ft) RJ-45
1000BASE- T Cat. 5 /Cat. 5e 100-ohm UTP UTP1 00m (328 ft) R J-45
IGS-9084GP-FB2
IGS-9084GP-FB2
15
Page 2
QIG
Quick InstallationGuide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Resetting
Toreboot the switch,press the button for2-3 seconds.
Torestore the switchconfigurations back tothe factory defaults,press the buttonfor 5 seconds.
Reset
Reset
Specifications
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
For pinassignments for differenttypes of cables,please refer tothe following tables.
10/100 Base-T(X)MDI/MDI-X
Pin Number MDI port MDI-X port
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3 RD+(receive) TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
Note: “+”and “-” signsrepresent the polarityof the wiresthat make upeach
wire pair.
Toconnect the consoleport to anexternal management device,you need anRJ-45 to DB-9 cable,which is alsosupplied in thepackage. Below isthe console portpin assignment information.
Console PortPin Definition
PC (male) pi n assignment
RS-232 with DB9 (female) pin
assignment (RJ45-D B9 cable)
RJ45 pin as signment
PIN#2RxD PIN#2RxD PIN#2RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5GND PIN#5GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1 (PWR1) and Power Supply2 (PWR2). Theconnections for PWR1, PWR2 andthe RELAYare located onthe terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat­blade screwdriverto tighten thewire-clamp screws onthe front ofthe terminal blockconnector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The twosets of relaycontacts of the6-pin terminal blockconnector are usedto detect user-configured events. Thetwo wires attachedto the faultcontacts form anopen circuit whena user-configured when an eventis triggered. Ifa user-configured eventdoes not occur,the faultcircuit remains closed.
Relay contact
Grounding andwire routing helplimit the effectsof noise dueto electromagnetic interference(EMI). Run theground connection fromthe ground screwsto the groundingsurface prior toconnecting devices.
Grounding
Configurations
After installingthe switch, thegreen power LEDshould turn on.Please refer tothe following tabletfor LED indication.
1. Launchthe Internet Explorerand type inIP address ofthe switch.The default staticIP address is
192.168.10.1
2. Login with defaultuser name andpassword (both are ). After loggingin, you should see the following screen. For more information on configurations, please referto the user manual. Forinformation on operatingthe switch using ORing’sOpen-Vision management utility, please goto ORing website.
admin
Follow thesteps to setup the switch:
ORingSwitchModel
IGS-9084GP-FB2-SS
PhysicalPorts
Technology
EthernetStandards
IEEE802.3 for 10Base-T IEEE802.3u for 100Base-TXand 100Base-FX IEEE802.3z for 1000Base-X IEEE802.3ab for 1000Base-T IEEE802.3ad for LACP(Link Aggregation ControlProtocol) IEEE802.3x for Flowcontrol, IEEE 802.1Dfor STP (SpanningTree Protocol) IEEE802.1p for COS(Class of service) IEEE802.1Q for VLANTagging IEEE802.1w for RSTP(Rapid Spanning TreeProtocol IEEE802.1s for MSTP(Multiple Spanning TreeProtocol) IEEE802.1x for Authentication
Power
RedundantInput power
Powerconsumption(Typ.)
DualDC inputs. 12-48VDCon 6-pin terminalblock
13watts max.
Overloadcurrent protection
Present
PhysicalCharacteristic
Enclosure
IP-30
Dimension(WxDxH)
96.4(W) x 105.5(D)x 154(H) mm(3.8 x 4.15x 6.06 inch)
10/100/1000Base-T(X)Ports inRJ45 Auto MDI/MDIX
MACTable
8K
RS-232Serial Console Port
PriorityQueues
8
Processing
Store-and-Forward
SwitchProperties
Switchlatency: 7 us Switchbandwidth: 24Gbps Max.Number of AvailableVLANs: 256 IGMPmulticast groups: 128for each VLAN Portrate limiting: UserDefine
SecurityFeatures
DeviceBinding security feature Enable/disableports, MAC basedport security Portbased network accesscontrol (802.1x) VLAN(802.1q) to segregateand secure networktraffic Radiuscentralized password management SNMPv3encrypted authentication andaccess security Https/ SSH enhancenetwork security
SoftwareFeatures
STP/RSTP/MSTP(IEEE 802.1D/w/s) RedundantRing (O-Ring) withrecovery time lessthan 10ms over250 units TOS/Diffservsupported Qualityof Service (802.1p)for real-time traffic VLAN(802.1Q) with VLANtagging and GVRPsupported IGMPSnooping for multicastfiltering IP-basedbandwidth management Application-basedQoS management DOS/DDOSauto prevention Portconfiguration, status, statistics,monitoring, security DHCPServer / Clientsupport SMTPClient ModbusTCP
NetworkRedundancy
O-Ring,Open-Ring, O-chain, STP,RSTP,MSTP
RS-232in RJ45 connectorwith console cable. Baud ratesetting: 115200bps, 8,N, 1
Weight (g)
1205g
Warning/ Monitoring System
Syslogserver / clientto record andview events IncludeSMTP for eventwarning notification viaemail Eventselection support
8
100/1000Base-Xwith SFP port
4
Jumboframe
Upto 9.6K Bytes
Weight (g)
710g 740g722g 735g 735g 740g
Environmental
-40to85C(-40to185F)
oo
StorageTemperature
-40to70C(-40to158F)
oo
OperatingTemperature
5%to 95% Non-condensingOperatingHumidity
RegulatoryApprovals
FCCPart 15, CISPR(EN55022) class AEMI
EN61000-4-2(ESD), EN61000-4-3 (RS),EN61000-4-4 (EFT), EN61000-4-5(Surge),EN61000-4-6 (CS), EN61000-4-8,EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
FreeFall
Warranty
5years
1000Base- TMDI/MD I-X
Pin NumberMDI portMDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4BI_DC+BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD - B I_DC-
`LED Color Status Description
PWR Green On D Cpower on
PWR1 Green On D Cpower module1 activated
PWR2 Green On D Cpower module2 activated
R.M Green On Ring Master
On Ri ngenabled
Ring Green
Blinking
Ringstructure isbroken(i.e. partof thering is
disconnected)
Fault Amber On Faulty relay(powerfailure orport disconnected)
10/100/1000Base-T(X) Gigabit Ethernet ports
On Po rtis linked
LNK/ACT Green
Blinking Transmitted data
Duplex Amber On Port infull duplexmode
SFP
On Po rtlink up
LNK/ACT Green
Blinking Datatransmitted
IGS-9084GP-FB2
IGS-9084GP-FB2
1000Base-T RJ-45 Po rt
PinNumber Assignment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5BI_DC-
6BI_DB-
7BI_DD+
8BI_DD-
ORing IndustrialNetworking Corp.
Copyright© 2014 ORing
All rightsreserved.
TEL: +886-2-2218-1066 FAX:+886-2-2218-1014
Website: www.oring-networking.com E-mail: [email protected]
Bypass Port Connection
The device provides two setsof bypass fiberports, giving theSFP fiber portsaddition redundancy capabilities.Connect a LCfiber cable from afiber port toa monitor port on the front panel and another LC fiber cable from the corresponding network port to another switch.
When theswitch breaks down,incoming traffic willtravel through the bypass portboard and ontoanother active switch.
IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
Note: thefiber port willstill work ifit is notconnected to anymonitor
port. However,the fiberport will nothave bypass abilitywhen the device isdown.
LCBypass Port Type
IGS-9084GP-FB2-MM
Single-Mode Multi-Mode
Reversepolarity protection
Present
10/100 Base-T(X) RJ-45 Port
Pin Number Assi gnments
1TD+
2TD-
3RD+
4 Not used
5 Not used
6RD-
7 Not used
8 Not used
Loading...