IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
Quick InstallationGuide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
The series isa managed industrialEthernet switch with
eight 10/100/1000Base-T(X)ports and four100/1000Base-X SFP ports.With
fiber opticalbypass design, theswitch can ensurecontinued network
operation whenany inline deviceon the networkfails. The switchsupports
Ethernet Redundancyprotocol, O-Ring (recoverytime < 30msover 250 units
of connection)and MSTP (RSTP/STPcompatible) to protectmission-critical
applications fromnetwork interruptions ortemporary malfunctions withfast
recovery technology. Witha wide operatingtemperature from -40 Cto 70 C,
the devicecan be managedcentrally via ORing’sproprietary Open-Vision
management utiltyas well asvia Web-based interfaces,Telnet, andconsole
(CLI). Theswitch is oneof the mostreliable choices forhighly-managed and
fiber Ethernetapplications.
IGS-9084GP-FB2
oo
Preparation
Before youbegin installing theswitch, make sureyou have allof the package
contents availableand a PCwith Microsoft InternetExplorer 6.0 orlater, for
using web-basedsystem management tools.
Elevated OperatingAmbient:
ReducedAir Flow:
Mechanical Loading:
If installed in a closed or multi-unit rack
assembly,the operating ambienttemperature of therack environment maybe
greater thanroom ambient. Therefore,consideration should begiven to
installing theequipment in anenvironment compatible withthe maximum
ambient temperature(Tma) specified bythe manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Safety & Warnings
Dimension
Panel Layouts
7
1. PowerLED
2. PWR1LED
3. PWR2LED
4. R.M.status LED
5. Ringstatus LED
6. Faultyrelay indicator
7. SFPport
8. Link/actionLED for
Gigabit Ethernetports
Package Contents
Contents
DIN-rail Kit
CD
IGS-9084GP-FB2
Pictures Number
X1
X1
X1
Front View
TopPanel
The device is shippedwith the followingitems. If anyof these itemsis
missing ordamaged, please contactyour customer servicerepresentative for
assistance.
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
QIG
Console Cable
X2
X1
X1
Wall-mountKit
33.0
30.0
12.5
105.5
10.9
15.0
70.5
154.0
96.4
87.0
48.0
17.5
94.0
124.0
48.0
58.0
7.50
R2.5
R3.95
80.5
62.0
87.9
10
14
1
2
3
4
5
6
Rear View
1
2
PWR-1PWR-2
1A@24V
DC48V
V2-V2+ V1-V1+
Fault
1
1. Wall-mountscrew holes
2. Din-railscrew holes
2
1. Terminalblocks: PWR1, PWR2
(12-48V DC),Relay
2. Groundwire.
1
Installation
Step 1:
Step 2:
Slant the switch and screwthe Din-railkit onto theback of theswitch, right in the
middle of the back panel.
Slide theswitch ontoa DIN-rail fromthe Din-rail kitand make surethe switch clicks
into therail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the twopieces of wall-mount kits onto bothends of the rear panel ofthe
switch. A total of six screws are required,as shown below.
Use the switch,with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Insert a screwhead through the large parts ofthe keyhole-shaped apertures,
and then slidethe switch downwards. Tighten thescrews for added stability.
Wall-mounting
QIG
1907-2-29-IGS9084GPFB2-1.0
Circuit Overloading:Consideration should begiven to theconnection of theequipment to the
supply circuitand the effectthat overloading ofthe circuits mighthave on overcurrentprotection
and supplywiring. Appropriateconsideration of equipmentnameplate ratings shouldbe used
when addressingthis concern.
11
8
9
Network Connection
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
9. DuplexLED for Gigabit
Ethernet ports
10. GigabitEthernet ports
11. Link/actionLED for SFPport
12. Bypassnetwork port
13. Bypassmonitor port
14. Consoleport
15. Resetbutton
12
13
IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
The switchprovides standard Ethernet ports. According to the link type, the
switch uses CAT 3,4, 5, 5e UTP cables to connect to any other network devices
(PCs, servers, switches, routers, or hubs). Please refer to the following table for
cable specifications.
Cable Typesand Specifications:
Cable Type Max. Length Conne ctor
10BASE-T Cat. 3, 4,5 100-ohm UTP 100m (328 ft) RJ-45
100BASE-TX Cat. 5100-ohmUTP UTP 100m(328 ft) RJ-45
1000BASE- T Cat. 5 /Cat. 5e 100-ohm UTP UTP1 00m (328 ft) R J-45
IGS-9084GP-FB2
IGS-9084GP-FB2
15

QIG
Quick InstallationGuide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Resetting
Toreboot the switch,press the button for2-3 seconds.
Torestore the switchconfigurations back tothe factory defaults,press the buttonfor 5 seconds.
Reset
Reset
Specifications
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
For pinassignments for differenttypes of cables,please refer tothe following
tables.
10/100 Base-T(X)MDI/MDI-X
Pin Number MDI port MDI-X port
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3 RD+(receive) TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
Note: “+”and “-” signsrepresent the polarityof the wiresthat make upeach
wire pair.
Toconnect the consoleport to anexternal management device,you need anRJ-45 to
DB-9 cable,which is alsosupplied in thepackage. Below isthe console portpin
assignment information.
Console PortPin Definition
PC (male) pi n assignment
RS-232 with DB9 (female) pin
assignment (RJ45-D B9 cable)
RJ45 pin as signment
PIN#2RxD PIN#2RxD PIN#2RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5GND PIN#5GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply2 (PWR2). Theconnections for PWR1,
PWR2 andthe RELAYare located onthe terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flatblade screwdriverto tighten thewire-clamp screws onthe front ofthe
terminal blockconnector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The twosets of relaycontacts of the6-pin terminal blockconnector are usedto detect user-configured
events. Thetwo wires attachedto the faultcontacts form anopen circuit whena user-configured when
an eventis triggered. Ifa user-configured eventdoes not occur,the faultcircuit remains closed.
Relay contact
Grounding andwire routing helplimit the effectsof noise dueto electromagnetic interference(EMI).
Run theground connection fromthe ground screwsto the groundingsurface prior toconnecting
devices.
Grounding
Configurations
After installingthe switch, thegreen power LEDshould turn on.Please refer tothe
following tabletfor LED indication.
1. Launchthe Internet Explorerand type inIP address ofthe switch.The default staticIP address is
192.168.10.1
2. Login with defaultuser name andpassword
(both are ). After loggingin, you should
see the following screen. For more information
on configurations, please referto the user
manual. Forinformation on operatingthe switch
using ORing’sOpen-Vision management utility,
please goto ORing website.
admin
Follow thesteps to setup the switch:
ORingSwitchModel
IGS-9084GP-FB2-SS
PhysicalPorts
Technology
EthernetStandards
IEEE802.3 for 10Base-T
IEEE802.3u for 100Base-TXand 100Base-FX
IEEE802.3z for 1000Base-X
IEEE802.3ab for 1000Base-T
IEEE802.3ad for LACP(Link Aggregation ControlProtocol)
IEEE802.3x for Flowcontrol, IEEE 802.1Dfor STP (SpanningTree Protocol)
IEEE802.1p for COS(Class of service)
IEEE802.1Q for VLANTagging
IEEE802.1w for RSTP(Rapid Spanning TreeProtocol
IEEE802.1s for MSTP(Multiple Spanning TreeProtocol)
IEEE802.1x for Authentication
Power
RedundantInput power
Powerconsumption(Typ.)
DualDC inputs. 12-48VDCon 6-pin terminalblock
13watts max.
Overloadcurrent protection
Present
PhysicalCharacteristic
Enclosure
IP-30
Dimension(WxDxH)
96.4(W) x 105.5(D)x 154(H) mm(3.8 x 4.15x 6.06 inch)
10/100/1000Base-T(X)Ports
inRJ45 Auto MDI/MDIX
MACTable
8K
RS-232Serial Console Port
PriorityQueues
8
Processing
Store-and-Forward
SwitchProperties
Switchlatency: 7 us
Switchbandwidth: 24Gbps
Max.Number of AvailableVLANs: 256
IGMPmulticast groups: 128for each VLAN
Portrate limiting: UserDefine
SecurityFeatures
DeviceBinding security feature
Enable/disableports, MAC basedport security
Portbased network accesscontrol (802.1x)
VLAN(802.1q) to segregateand secure networktraffic
Radiuscentralized password management
SNMPv3encrypted authentication andaccess security
Https/ SSH enhancenetwork security
SoftwareFeatures
STP/RSTP/MSTP(IEEE 802.1D/w/s)
RedundantRing (O-Ring) withrecovery time lessthan 10ms over250 units
TOS/Diffservsupported
Qualityof Service (802.1p)for real-time traffic
VLAN(802.1Q) with VLANtagging and GVRPsupported
IGMPSnooping for multicastfiltering
IP-basedbandwidth management
Application-basedQoS management
DOS/DDOSauto prevention
Portconfiguration, status, statistics,monitoring, security
DHCPServer / Clientsupport
SMTPClient
ModbusTCP
NetworkRedundancy
O-Ring,Open-Ring, O-chain, STP,RSTP,MSTP
RS-232in RJ45 connectorwith console cable. Baud ratesetting: 115200bps, 8,N, 1
Weight (g)
1205g
Warning/ Monitoring System
Syslogserver / clientto record andview events
IncludeSMTP for eventwarning notification viaemail
Eventselection support
8
100/1000Base-Xwith SFP port
4
Jumboframe
Upto 9.6K Bytes
Weight (g)
710g 740g722g 735g 735g 740g
Environmental
-40to85C(-40to185F)
oo
StorageTemperature
-40to70C(-40to158F)
oo
OperatingTemperature
5%to 95% Non-condensingOperatingHumidity
RegulatoryApprovals
FCCPart 15, CISPR(EN55022) class AEMI
EN61000-4-2(ESD), EN61000-4-3 (RS),EN61000-4-4 (EFT), EN61000-4-5(Surge),EN61000-4-6 (CS), EN61000-4-8,EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
FreeFall
Warranty
5years
1000Base- TMDI/MD I-X
Pin NumberMDI portMDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4BI_DC+BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD - B I_DC-
`LED Color Status Description
PWR Green On D Cpower on
PWR1 Green On D Cpower module1 activated
PWR2 Green On D Cpower module2 activated
R.M Green On Ring Master
On Ri ngenabled
Ring Green
Blinking
Ringstructure isbroken(i.e. partof thering is
disconnected)
Fault Amber On Faulty relay(powerfailure orport disconnected)
10/100/1000Base-T(X) Gigabit Ethernet ports
On Po rtis linked
LNK/ACT Green
Blinking Transmitted data
Duplex Amber On Port infull duplexmode
SFP
On Po rtlink up
LNK/ACT Green
Blinking Datatransmitted
IGS-9084GP-FB2
IGS-9084GP-FB2
1000Base-T RJ-45 Po rt
PinNumber Assignment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5BI_DC-
6BI_DB-
7BI_DD+
8BI_DD-
ORing IndustrialNetworking Corp.
Copyright© 2014 ORing
All rightsreserved.
TEL: +886-2-2218-1066
FAX:+886-2-2218-1014
Bypass Port Connection
The device provides two setsof bypass fiberports, giving theSFP
fiber portsaddition redundancy capabilities.Connect a LCfiber cable
from afiber port toa monitor port on the front panel and another
LC fiber cable from the corresponding network port to another
switch.
When theswitch breaks down,incoming traffic willtravel through the
bypass portboard and ontoanother active switch.
IGS-9084GP-FB2
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
A
A
Network
B
TX
RX
B
TX
RX
TX
RX
TX
RX
Monitor
Note: thefiber port willstill work ifit is notconnected to anymonitor
port. However,the fiberport will nothave bypass abilitywhen the
device isdown.
LCBypass Port Type
IGS-9084GP-FB2-MM
Single-Mode Multi-Mode
Reversepolarity protection
Present
10/100 Base-T(X) RJ-45 Port
Pin Number Assi gnments
1TD+
2TD-
3RD+
4 Not used
5 Not used
6RD-
7 Not used
8 Not used