IGS-9164GF
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
G20
G19
G18
G17
1000FX
G16
G14
G12
G10
G15
G13
G11
G9
Quick InstallationGuide
Version 1.1
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
QIG
The is amanaged industrial Ethernetswitch with
16x10/100/1000Base-T(X) portsand 4 fixed optical fiber ports. The IGS9164GF provides4x1000Base-X fiber portsand the IGS-9164FXprovides
4x100Base-FX fiberports. The cost-effectivedevice with ahigh port density
can bemanaged centrally viaweb browsers, TELNET, Consoleor other
third-party SNMPsoftware as wellas Oring’s proprietaryOpen-Vision
management utility. With completesupport for Ethernetredundancy
protocols suchas O-Ring (recoverytime < 30msover 250 unitsof
connection) andMSTP (RSTP/STP compatible),the devices canprotect
your mission-criticalapplications from networkinterruptions or temporary
malfunctions withits fast recoverytechnology. Boastinga wide operating
temperature from-40 C to 75 C, the switch can meet the demanding
requirements of power substations and rollingstock applications.
IGS-9164GF/FX series
oo
Dimension
Panel Layouts
11
1. PowerLED
2. PWR1LED
3. PWR2LED
4. R.M.status LED
5. Ringstatus LED
6. Faultyrelay indicator
7. Consoleport
8. Opticalfiber ports
9. LNK/ACTindicator for
fiber ports
10. LNK/ACTindicator for
LAN ports
11. EthernetLAN ports
12. Speedindicator for LAN
ports
13. Resetbutton
Package Contents
Contents
DIN-rail Kit
CD
IGS-9164GF/FX
Pictures Number
X1
X1
X1
Front View
TopPanel
The are shippedwith the followingitems. If anyof
these itemsis missing ordamaged, please contactyour customer service
representative forassistance.
IGS-9164GF/FX eries
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
QIG
Console Cable
X2
X1
X1
Wall-mountKit
33.0
30.0
12.5
105.5
10.9
15.0
70.5
154.0
96.4
87.0
48.0
17.5
94.0
124.0
48.0
58.0
7.50
R2.5
R3.95
66.25
48.75
95.9
10
8
7
1
2
3
4
5
6
Rear View
1
2
PWR-1PWR-2
1A@24V
DC48V
V2-V2+ V1-V1+
Fault
1
1. Wall-mountscrew holes
2. Din-railscrew holes
2
1. Terminalblocks: PWR1, PWR2
(12-48V DC),Relay
2. Groundwire.
1
Installation
Step 1:
Step 2:
Slant the switch and screwthe Din-railkit onto theback of theswitch, right in
the middle of the back panel.
Slide theswitch ontoa DIN-rail fromthe Din-rail kitand make surethe switch
clicks intothe rail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the twopieces of wall-mount kits onto bothends of the rear panel ofthe
switch. A total of six screws are required,as shown below.
Use the switch,with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Insert four screwheads through the large parts ofthe keyhole-shaped apertures,
and then slidethe switch downwards. Tighten thefour screws for added stability.
Wall-mounting
IGS-9164GF/FX Series
1907-2-29-IGS9164GF-1.1
Network Connection
The switchprovides standard Ethernet ports. According to the link type, the switch
uses CAT 3, 4,5, 5e UTP cables to connect to any other network devices (PCs,
servers, switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Typesand Specifications:
Cable Type Max. Length Conne ctor
10BASE-T Cat. 3, 4,5 100-ohm UTP 100m (328 ft) RJ-45
100BASE-TX Cat.5 100-ohmUTP UTP100 m(328 ft) RJ-45
1000BASE- T Cat. 5 /Cat. 5e 100-ohm UTP UTP100 m (328 ft) RJ-4 5
IGS-9164GF/FX Series
Preparation
Before youbegin installing theswitch, make sureyou have allof the package
contents availableand a PCwith Microsoft InternetExplorer 6.0 orlater, for
using web-basedsystem management tools.
Elevated OperatingAmbient:
ReducedAir Flow:
If installed in a closed or multi-unit rack
assembly,the operating ambienttemperature of therack environment maybe
greater thanroom ambient. Therefore,consideration should begiven to
installing theequipment in anenvironment compatible withthe maximum
ambient temperature(Tma) specified bythe manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Safety & Warnings
Mechanical Loading:
Circuit Overloading:
Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Consideration shouldbe given tothe connection ofthe equipment to
the supplycircuit and theeffect that overloadingof the circuitsmight have onovercurrent
protection andsupply wiring.Appropriate consideration ofequipment nameplate ratings
should beused when addressing thisconcern.
IGS-9164GF
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
G20
G19
G18
G17
1000FX
G16
G14
G12
G10
G15
G13
G11
G9
9
12
IGS-9164GF
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
G20
G19
G18
G17
1000FX
G16
G14
G12
G10
G15
G13
G11
G9
13
IGS-9164FX
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
P20
P19
P18
P17
100FX
G16
G14
G12
G10
G15
G13
G11
G9
IGS-9164FX
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G7
G5
G3
G1
LNK/ACT
LNK/ACT
P20
P19
P18
P17
100FX
G16
G14
G12
G10
G15
G13
G11
G9
11
10
8
7
1
2
3
4
5
6
9
12
13
QIG
Quick InstallationGuide
PRINTED ON RECYCLED PAPER
Version 1.1
Quick Installation Guide
Resetting
Toreboot the switch,press the button for2-3 seconds.
Torestore the switchconfigurations back tothe factory defaults,press the buttonfor 5 seconds.
Reset
Reset
Specifications
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
For pinassignments for differenttypes of cables,please refer tothe following
tables.
1000Base- TRJ-45
Pin Number Assignment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5BI_DC-
6BI_DB-
7BI_DD+
8BI_DD-
10/100Base-T(X)MDI/MDI- X
Pin Number MDI port MDI-X port
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3 RD+(receive) TD+(transmit )
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
Note: “+”and “-” signsrepresent the polarityof the wiresthat make upeach
wire pair.
Toconnect the consoleport to anexternal management device,you need anRJ-45 to
DB-9 cable,which is alsosupplied in thepackage. Below isthe console portpin
assignment information.
Console PortPin Definition
PC (male) pi n assignment
RS-232 with DB9 (female) pin
assignment (RJ45-D B9 cable)
RJ45 pin as signment
PIN#2RxD PIN#2RxD PIN#2RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5GND PIN#5 GND PIN#5 GND
Configurations
After installingthe switch card,the green powerLED should turnon. Please referto the
following tabletfor LED indication.
1. Launchthe Internet Explorerand type inIP address ofthe switch.The default staticIP address is
192.168.10.1
2. Login with defaultuser name andpassword
(both are ). After loggingin, you should
see the following screen. For more information
on configurations, please referto the user
manual. Forinformation on operatingthe switch
using ORing’sOpen-Vision management utility,
please goto ORing website.
admin
Follow thesteps to setup the device:
ORingSwitch Model
IGS-9164GF-MM-SC
PhysicalPorts
FiberPorts Number
Technology
EthernetStandards
IEEE802.3 for 10Base-T
IEEE802.3u for 100Base-TXand 100Base-FX
IEEE802.3z for 1000Base-X
IEEE802.3ab for 1000Base-T
IEEE802.3ad for LACP(Link Aggregation ControlProtocol)
IEEE802.3x for Flowcontrol
IEEE802.1p for COS(Class of service)
IEEE802.1Q for VLANTagging
IEEE802.1w for RSTP(Rapid Spanning TreeProtocol
IEEE802.1s for MSTP(Multiple Spanning TreeProtocol)
IEEE802.1x for Authentication
IEEE802.1AB for LLDP(Link Layer DiscoveryProtocol)
Power
RedundantInput power
Powerconsumption(Typ.)
DualDC inputs. 12-48VDCon 6-pin terminalblock
16.32Watts
Overloadcurrent protection
Reversepolarity protection
Present
Present
PhysicalCharacteristic
Enclosure
IP-30
Dimension(WxDxH)
96.4(W) x 105.5(D)x 154(H) mm(3.8 x 4.15x 6.06 inch)
10/100/1000Base-T(X)Ports
inRJ-45 Auto MDI/MDIX
MACTable
8K
RS-232Serial Console Port
PriorityQueues
8
Processing
Store-and-Forward
SwitchProperties
Switchlatency: 7 us
Switchbandwidth: 40Gbps
Max.Number of AvailableVLANs: 256
IGMPmulticast groups: 128for each VLAN
Portrate limiting:User Define
SecurityFeatures
DeviceBinding security feature
Enable/disableports, MAC basedport security
Portbased network accesscontrol (802.1x)
VLAN(802.1q) to segregateand secure networktraffic
Radiuscentralized passwordmanagement
SNMPv3encrypted authentication andaccess security
Https/ SSH enhancenetwork security
SoftwareFeatures
STP/RSTP/MSTP(IEEE 802.1D/w/s)
RedundantRing (O-Ring) withrecovery timeless than 30msover 250 units
TOS/Diffservsupported
Qualityof Service (802.1p)for real-time traffic
VLAN(802.1Q) with VLANtagging and GVRPsupported
IGMPSnooping for multicastfiltering
IP-basedbandwidth management
Application-basedQoS management
DOS/DDOSauto prevention
Portconfiguration, status,statistics, monitoring, security
DHCPServer / Clientsupport
SMTPClient
ModbusTCP
NetworkRedundancy
O-Ring,Open-Ring, O-chain, MRP,MSTP (RSTP/STPcompatible), FastRecovery
RS-232in RJ45 connectorwith console cable. Baud ratesetting: 115200bps, 8,N, 1
FiberPorts Specification
FiberPorts Standard
1000Base-SX
FiberMode
Multi-mode Single-mode
FiberDiameter ( m)µ
62.5/125 m
50/125 mµµ
FiberOptical Connector
SC SC
TypicalDistance (Km)
0.55Km 30Km
Wavelength(nm)
850nm 1310nm
Max.Output Optical Power
(dbm)
-8dbm
Min.Output Optical Power
(dbm)
-15dbm
OpticalInput Powerminimum(Sensitivity)
-34dbm
0dbm -0dbm
-18dbm
OpticalInput Powermaximum(Saturation)
LinkBudget (db)
8.5db 19db
Weight (g)
1243g
16
9/125 mµ
IGS-9164FX-SS-SC
4
Processing
Upto 9.6K Bytes
FaultContact
Relay
Relayoutput tocarry capacity of 1Aat 24VDC
Weight (g)
710g 740g722g 735g 735g 740g
Environmental
-40to85C(-40to185F)
oo
StorageTemperature
-40to75C(-40to167F)
oo
OperatingTemperature
5%to 95% Non-condensingOperatingHumidity
RegulatoryApprovals
FCCPart 15, CISPR(EN55022) class AEMI
EN61000-4-2(ESD), EN61000-4-3 (RS),EN61000-4-4 (EFT), EN61000-4-5(Surge),EN61000-4-6 (CS), EN61000-4-8,EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
FreeFall
Warranty
5years
100Base-FX
10/100Base-T(X)RJ-45
Pin Numbe r Assignment
1TD+
2TD-
3RD+
4Notused
5Notused
6RD-
7Notused
8Notused
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
-4dbm
-9.5dbm
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply2 (PWR2). Theconnections for PWR1,
PWR2 andthe RELAYare located onthe terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flatblade screwdriverto tighten thewire-clamp screws onthe front ofthe
terminal blockconnector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The twosets of relaycontacts of the6-pin terminal blockconnector are usedto detect userconfigured events.The two wiresattached to thefault contacts forman close circuitwhen a
user-configured eventis triggered. Ifa user-configured eventdoes not occur,the fault
circuit remainsopened.
Relay contact
Grounding andwire routing helplimit the effectsof noise dueto electromagnetic
interference (EMI).Run the groundconnection from theground screws tothe grounding
surface priorto connecting devices.
Grounding
ORing IndustrialNetworking Corp.
Copyright© 2014 ORing
All rightsreserved.
TEL: +886-2-2218-1066
FAX:+886-2-2218-1014
Website: www.oring-networking.com
E-mail: support@oring-networking.com
LED Color Status Description
PWR Green On DC poweron
PW1 Green On DCpower mo dule 1 activ ated
PW2 Green On DCpower mo dule 2 activ ated
R.M Green On System running in Ri ng Master mode
On System runni ng in Ring mode
Ring Gre en
Blinking Ring structur e is broken
Fault Amber On F aulty relay (power fa ilure or port malfunct ioning)
10/100/1000Ba se-T(X) Etherne t ports
On Port is co nnected
LNK/ACT Green
Blinking Transmitting data
Green On Port i s running at 1000Mbps
Amber On P ort is runni ng at 100Mb ps
Speed
Off Port is r unning at 10 Mbps
1000Base-X or 100Base- FX fiber port s
On Port is co nnected
LNK/ACT Green
Blinking Transmitting data
Single-mode
SC
10Km
1310nm
-3dbm
-9.5dbm
-20dbm
-3dbm
10.5db
9/125 mµ
IGS-9164GF-SS-SC
1000Base-LX
IGS-9164FX-MM-SC
100Base-FX
Multi-mode
62.5/125 m
50/125 mµµ
SC
2Km
1310nm
0dbm
-31dbm
7.5db
-14dbm
-23.5dbm
18.5Watts
1228g
IGS-9164GF/FX Series
IGS-9164GF/FX Series