The Security Door Lock XC/XM series are a standalone, battery operated, motorized
lock with an encrypted reader, remote control unit (RCU) and applicable encrypted
cards. The programming of the lock and Keycards is done using the reader of the lock.
XC model- RFID with a Grade 1 cylindrical lock body
XM model- RFID with a Grade 1 mortise lock body
Keycards:
Keycards come with an imbedded RFID chip and antenna, there is no battery in the
keycards. The keycards are encrypted and only these cards can be used and
programmed to work with the security door lock. Encryption is on sector 1 of the cards,
other sectors can be used for other purposes independent of the lock. Keycards are
labeled with their “type” and function- a Keycard can only be programmed for their
labeled function.
Keycards exchange data with the lock by “swiping” the Keycard within the effective
reading distance (0 to ½”) of the lock reader surface that is located on the front face of
the lock. The Keycard needs to be authorized (programmed) before use with the lock.
For identification and Keycard control all Keycards have a unique serial number that is
printed on the Keycard surface.
250 keycards (combined total of User, Office and Lockdown Cancel Keycards) can be
programmed into each lock. 120 RCUs can be programmed into each lock.
The following is a description of the type of Keycards and function:
Construction Keycard- Used for opening the lock in the Factory Mode, the door will
relock within 5 seconds after opening. The lock is shipped from the factory in Factory
Mode, it is not programmed and any Factory Mode lock will work with any Construction
Keycard. It is recommended that the locks be programmed as soon as possible. The
Construction Keycard will not work in a programmed lock.
User Keycard- Used to open the lock once it is programmed. Under normal conditions
the lock will relock within 5 seconds after opening. During lockdown mode the User
Keycard will open the lock and will relock within 2 seconds.
Office Keycard- Used to open and lock the lock once it is programmed. Under normal
conditions the Office Keycard will open the lock and it will remain open until the Office
Keycard is used again and it will lock the lock. During lockdown mode the User Keycard
will open the lock and will relock within 2 seconds.
Remote Control Unit (RCU)- used to put lock in the Lockdown Mode. Pushing the
button for 1 second on the RCU will enter the lock in the Lockdown Mode. If the lock is
open it will lock. In the Lockdown Mode the User and Office Keycards will only open the
locks for 2 seconds before it relocks. Only the Lockdown Cancel Keycard can cancel the
- 2 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
Lockdown Mode. The RCU also has an Office Keycard imbedded in the unit. This can
be used and programmed exactly like the Office Keycard by swiping the RCU on the
lock reader.
Lockdown Cancel Keycard- Used to cancel the lockdown mode. The Lockdown Cancel
Keycard does not open the lock after the lockdown mode is canceled.
Programming Keycard- Used for programming User Keycards, Office Keycards, RCUs
and importing information into the lock. Can only program 1 Programming Keycard per
lock.
Clear Keycard- Used for deleting User Keycards, Office Keycards, RCUs and exporting
information from the lock. Can only program 1 Clear Keycard per lock.
Register Keycard- Used as a backup in the event that the Programming and/or Clear
Keycard(s) are lost. The Register Keycard can program a new Programming or Clear
Keycard and makes the previous Programming or Clear Keycards inactive. Can only
program 1 Register Keycard per lock.
Database Keycard- Used to download and upload data to and from the lock. Database
Keycard can be used to export information from 1 programmed lock and import that
information into another programmed lock. Database Keycard has more memory than
the other cards used.
The Programming, Clear and Register Keycards are critical to the overall control of the
lock system and it is recommended that these cards be kept in a secure location and
controlled. If possible the Register Keycard should be kept in a separate location.
Programming and Initialization of the RFID Lock:
Initialization: The lock needs to be initialized using the Programming, Clear and Register
Keycards. Once initialized the lock will not respond to the Construction Keycard or other
Programming/Clear/Register Keycards. Once initialized the lock is ready for
programming. Initialization can only be done on locks in Factory Mode.
Procedure for Initialization:
Swipe the keys in the listed order. Valid entry- Blue LED followed by a short and long
“beep”. Invalid entry- Red LED followed by 3 short “beeps”.
1. Programming Keycard (swipe)- Blue LED followed by a short and long “beep”
2. Clear Keycard (swipe)- Blue LED followed by a short and long “beep”
3. Register Keycard (swipe)- Blue LED followed by a short and long “beep”
IMPORTANT: All 3 Keycards must be used and accepted as valid to complete the
Initialization. In all cases the Register Keycard must but used last.
Once the unit is initialized it is ready for further programming.
- 3 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
Programming- Adding Keycards and RCUs to the lock:
This is to add /program Keycards (up to 250 per lock) and RCUs (up to 120 per lock) to
the lock. Swiping the Programming Keycard will put the lock in Programming Mode.
Programming Mode will continue for 8 seconds after the last valid card was swiped.
When the Programming Keycard is swiped the Programming Mode is indicated by a
long “beep” and a flashing blue LED (the LED will continue flashing until the lock is out
of Programming Mode). During Programming Mode the Keycards and RCUs can be
added (programmed into the lock).
Swipe the keys in the listed order (steps 3, 4, 5 can be done in any sequence):
1. Programming Keyca rd (swipe)- Long “beep” and a continuous flashing blue LED
2. User Keycards (swipe)- Blue LED followed by a short and long “beep”- LED will
continue flashing- can add as many User Keycards during this time as needed
(remember- combined total of all the User, Office and Lockdown Cancel
Keycards that can be added is 250).
3. Office Keycards (swipe)- Blue LED followed by a short and long “beep”- LED will
continue flashing- can add as many Office Keycards during this time as needed
(remember- combined total of all the User, Office and Lockdown Cancel
Keycards that can be added is 250).
4. Lockdown Cancel Keycards (swipe)- Blue LED followed by a short and long
“beep”- LED will continue flashing- can add as many Lockdown Cancel
Keycards during this time as needed (remember- combined total of all the User,
Office and Lockdown Cancel Keycards that can be added is 250).
5. RCUs (press emergency button)- Blue LED followed by a short and long “beep”-
LED will continue flashing- can add as many RCUs during this time as needed
(remember- total of all RCUs that can be added is 120).
Lock will stop flashing 8 seconds after the last valid card is swiped. When the LED stops
flashing it is out of programming mode. In order to put it back into programming mode
again- swipe the Programming Keycard. The Keycards and RCUs can be added in any
sequence when the lock is in programming mode. You cannot stack Keycards- the lock
will not recognize stacked Keycards- you must swipe Keycards 1 at a time.
Programming- Deleting Keycards and RCUs from the lock:
This is to delete Keycards and RCUs (that are in your possession) from the lock.
Swiping the Clear Keycard will put the lock in Delete Mode. Delete Mode will continue
for 8 seconds after the last valid card was swiped. When the Clear Keycard is swiped
the Delete Mode is indicated by a long “beep” and a flashing red LED (the LED will
continue flashing until the lock is out of Delete Mode). During Delete Mode the Keycards
and RCUs can be deleted (no longer valid).
Swipe the keys in the listed order (steps 3, 4, 5 can be done in any sequence):
1. Clear Keycard (swipe)- Long “beep” and a continuous flashing red LED
- 4 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
2. User Keycards (swipe)- Blue LED followed by a short and long “beep”- red LED
will continue flashing- can delete as many User Keycards during this time as
needed.
3. Office Keycards (swipe)- Blue LED followed by a short and long “beep”- red LED
will continue flashing- can delete as many Office Keycards during this time as
needed.
4. Lockdown Cancel Keycards (swipe)- Blue LED followed by a short and long
“beep”- red LED will continue flashing- can delete as many Lockdown Cancel
Keycards during this time as needed.
5. RCUs (press emergency button)- Blue LED followed by a short and long “beep”-
red LED will continue flashing- can delete as many RCUs during this time as
needed.
Lock will stop flashing 8 seconds after the last valid card is swiped. When the LED stops
flashing it is out of Delete Mode. In order to put it back into Delete Mode again- swipe
the Clear Keycard. The Keycards and RCUs can be deleted in any sequence when the
lock is in Delete Mode. You cannot stack Keycards- the lock will not recognize stacked
Keycards- you must swipe Keycards 1 at a time.
Programming- Deleting Keycards and RCUs from the lock that are lost:
This is to delete Keycards and RCUs, which are not in your possession, from the lock.
When you do not have the Keycard or RCU that you want to delete you have the ability
to delete all Keycards of a certain type or RCUs from that specific lock. Swiping the
Clear Keycard 2X will put the lock in this type of Delete Mode. Deleting a RCU in this
manner will delete all RCUs programmed for this specific lock. Deleting a Lockdown
Cancel Keycard will delete all Lockdown Cancel Keycards programmed for this specific
lock. Deleting a User or Office Keycard will delete all User and Office Keycards
programmed for this specific lock, User and Office Keycards are considered the same
type of Keycard and will be deleted regardless if an Office or if a User Keycard is used
for this deleting operation. When the Clear Keycard is swiped there is a long “beep” and
a flashing red LED- swipe the Clear Keycard again and there is a short “beep” and the
red LED will flash faster. Swipe (or push the lockdown button on the RCU) the Keycard
type you are deleting and follow this with swiping the Clear Keycard. The red LED will
stop flashing after the last Clear Keycard is swiped.
Swipe the keys in the listed order (Clearing/Deleting all Office and User Keycards):
1. Clear Keycard (swipe)- short “beep” and a continuous flashing red LED
2. Clear Keycard (swipe)- longer “beep” and the red LED will flash faster.
3. Office or User Keycard (swipe)- Blue LED followed by a long “beep”- red LED
will continue flashing.
4. Clear Keycard (swipe)- Blue and red LED followed by a short and long “beep”-
red LED will stop flashing.
Swipe the keys in the listed order (Clearing/Deleting all Lockdown Cancel Keycards)
1. Clear Keycard (swipe)- short “beep” and a continuous flashing red LED
- 5 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
2. Clear Keycard (swipe)- longer “beep” and the red LED will flash faster.
3. Lockdown Cancel Keycard (swipe)- Blue LED followed by a long “beep”- red
LED will continue flashing.
4. Clear Keycard (swipe)- Blue and red LED followed by a short and long “beep”-
red LED will stop flashing.
Swipe the keys in the listed order (Clearing/Deleting all RCUs)
1. Clear Keycard (swipe)- short “beep” and a continuous flashing red LED
2. Clear Keycard (swipe)- longer “beep” and the red LED will flash faster.
3. RCU (press lockdown button))- Blue LED followed by a long “beep”- red LED will
continue flashing.
4. Clear Keycard (swipe)- Blue and red LED followed by a short and long “beep”-
red LED will stop flashing.
After deleting the type of Keycard or RCU- the lost or misplaced keycard or RCU will no
longer work on this lock. In order to re-program the lock to add the Keycards and/or
RCUs that were deleted follow the instruction Programming- Adding Keycards and
RCUs to the lock. The programming may, also, be done using the Database Card-
follow the instruction Database Keycard Programming.
Programming- Deleting all Keycards and RCUs from the lock except the
Programming, Clear and Register Keycards:
This is to delete all Keycards and RCUs from the lock. The lock does not delete the
Programming, Clear or Register Keycards and the lock remains initialized.
Swipe the keys in the listed order (Clearing/Deleting all Keycards and RCUs from the
lock)
1. Clear Keycard (swipe)- short “beep” and a continuous flashing red LED
2. Programming Keycard (swipe)- short “beep” and the red LED will continue to
flash.
3. Programming Keycard (swipe)- Blue LED followed by a short and long “beep”-
red and blue LED will flash for 2 seconds.
After deleting the Keycards (User, Office and Lockdown Cancel) the lock is still
initialized and the Programming, Clear and Register Keycards still function. In order to
re-program the lock to add the Keycards and/or RCUs that were deleted follow the
instruction Programming- Adding Keycards and RCUs to the lock. The programming
may, also, be done using the Database Card- follow the instruction Database Keycard
Programming.
Factory Reset:
This is will delete all Keycards, RCUS and the lock is no longer initialized. The lock will
be in Factory Mode and the Construction Keycard will open the lock.
Swipe the keys in the listed order (puts lock into the Factory Mode)
1. Clear Keycard (swipe)- short “beep” and a continuous flashing red LED
2. Clear Keycard (swipe)- short “beep” and a continuous flashing red LED
- 6 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
3. Programming Keycard (swipe)- short “beep” and the red LED will continue to
flash.
4. Programming Keycard (swipe)- Blue LED followed by a short and long “beep”-
red and blue LED will flash for 2 seconds.
In order to re-program the lock to add the Keycards and/or RCUs that were deleted
follow the instruction Programming and Initialization of the RFID Lock and
Programming- Adding Keycards and RCUs to the lock. The programming may, also,
be done using the Database Card- follow the instruction Database Keycard
Programming.
Database Keycard Programming:
The Database Keycard is used to import and export information. The Database Keycard
can export or retrieve information from a programmed lock and this information can be
imported or passed on to another lock to clone that lock. Each lock will have the same
authorizations and the same Keycards/RCUs will work on both locks.
Database Keycard- Exporting (retrieving information from a lock):
Once a lock is programmed- you can use the Database Keycard to retrieve the
information from the lock and store it on the Database Keycard. The information will stay
on the Database Keycard until it is overwritten by using it again to export additional
information from a lock to the card- the original data is overwritten and only the newest
data is available. The Database Keycard is rated for 100,000 cycles minimum.
Swipe the keys in the listed order (exports information from the lock to the Database
Keycard)
1. Clear Keycard (swipe)- short “beep” and a continuous flashing red LED
2. Database Keycard (swipe and hold)- short “beep” and a continuous flashing
blue LED- after approximately 5 seconds you will get 2 short “beeps” and a final
blue LED.
The Database Keycard needs to be held against the reader until all the information is
exported to the card. The Database Keycard can now be used to import information into
a lock or it can be used as an archive of the information in the lock.
Database Keycard- Importing (transferring information to a lock):
This will program the lock using the information on the Database Keycard. The lock
can import information from the Database Keycard and the lock will be a “clone” of the
lock that the Database Keycard retrieved its information from- it will be programmed as a
clone in regard to Keycard and RCU authorizations (same initialization and
programming). The information can be transferred to the lock if the lock is in Factory
Mode or if it is already programmed.
Lock is already programmed- Swipe the keys in the listed order (the lock imports
information from the Database Keycard)
1. Program Keycard (swipe)- short “beep” and a continuous flashing blue LED
- 7 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
2. Database Keycard (swipe and hold)- short “beep” and a continuous flashing
blue LED- after approximately 5 seconds you will get 2 short “beeps” and a final
blue LED.
Lock is in Factory Mode- Swipe the keys in the listed order (the lock imports information
from the Database Keycard)
1. Database Keycard (swipe and hold)- short “beep” and a continuous flashing
blue LED- after approximately 5 seconds you will get 2 short “beeps” and a final
blue LED.
The Database Keycard needs to be held against the reader until all the information is
transferred to the lock. The Database Keycard can now be used to program additional
locks as needed.
Lost Programming and/or Clear Keycard:
If a Programming or Clear Keycard is lost this will instruct you on how to make a new
card and the lost cards will no longer be authorized. You must contact technical support
(phone number and website is listed on all the Keycards) and obtain a new
Programming or Clear Keycard to replace the lost Keycard. Once the new Keycard is
received do the following:
Swipe the keys in the listed order (steps 3, 4, 5 can be done in any sequence):
1. Register Keycard (swipe)- Long “beep” and a continuous flashing blue LED
2. New Programming or Clear Keycard (swipe)- Blue LED and a long “beep”- blue
LED will continue flashing.
3. Register Keycard (swipe)- Short and long “beep”- blue LED will stop flashing.
This will authorize the new Programming or Clear Keycard. No other Programming or
Clear Keycard will now work with that lock. These are standalone locks and this must be
done to each lock to authorize the new Keycard on each of those locks.
Lost Register Keycard:
If a Register Keycard is lost this will instruct you on how to obtain a new card and the
lost card will no longer be authorized. You must contact technical support (phone
number and website is listed on all the Keycards) and obtain a new Register Keycard to
replace the lost Keycard. Once the new Keycard is received do the following:
Swipe the keys in the listed order (1
st
lock):
1. Register Keycard (swipe)- Long “beep” and a continuous flashing blue LED
2. New Programming or Clear Keycard (swipe)- Blue LED and a long “beep”- blue
LED will continue flashing.
3. Register Keycard (swipe)- Short and long “beep”- blue LED will stop flashing.
Swipe the keys in the listed order (subsequent locks):
1. Register Keycard (swipe)- short and long “beep” and a continuous flashing blue
LED
- 8 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
2. New Programming or Clear Keycard (swipe)- Blue LED and a long “beep”- blue
LED will continue flashing for 8 seconds.
This will authorize the new Programming or Clear Keycard. No other Programming or
Clear Keycard will now work with that lock. These are standalone locks and this must be
done to each lock to authorize the new Keycard on each of those locks (1
st
lock
programming is different from the subsequent locks).
Lost Programming, Clear and Register Keycards:
If all 3 Keycards are lost this will instruct you on how to obtain a new set of cards and the
lost cards will no longer be authorized. If you have already used the Database Keycard
and it has the information from 1 of the programmed locks you send the Database
Keycard to the service center (technical support phone number and website is listed on
all the Keycards).
If you do not have a Database Keycard with the lock information:
1. Open the back cover
2. Press the Clear Button (see illustration) - wait for 1 short “beep” and a
continuous flashing blue LED
3. Swipe and hold the Database Keycard- short “beep” and a continuous flashing
blue LED- after approximately 5 seconds you will get 1 short and 1 long “beep”
and a final blue LED.
This will program a Database Keycard with the information from the lock that was used.
Send the Database Keycard to the service center.
The service center will issue new Keycards. Once the Keycards are received do the
following:
Swipe the keys in the listed order (1
st
lock):
1. Register Keycard (swipe)- Short “beep” and a continuous flashing blue LED
2. New Programming Keycard (swipe)- Wait for short and long “beep”- blue LED
will continue flashing.
3. Repeat steps 1 and 2 on all locks.
Low Battery warning:
The lock operates on 4 AA alkaline batteries only. Low battery warning will come on at
approximately 4.8 volts. The only way to reset the lock and get out of low battery
warning is to replace the batteries with new AA alkaline batteries. Important: Always
replace all 4 batteries with new batteries.
The following warnings will occur at different intervals:
1. The 1st 50 times you open the door after the low battery threshold (~4.8 volts) is
reached- Swipe an authorized Keycard- 3 “beeps” followed by 3 “beeps” (6
“beeps” total) and the lock unlocks
- 9 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
2. Using the lock 51-100 times after the low battery warning threshold is reached-
Swipe an authorized Keycard- 3 “beeps” followed by 3 “beeps” followed by 3
“beeps” (9 “beeps” total) and the lock unlocks
3. After 100 times or under very low voltage conditions- “3 beeps” 4 times (12
“beeps” total) and then only the Programming Keycard will unlock the lock.
Do not wait for the low battery warning- it is recommended under normal use that the
batteries be changed every 12 months. If the low battery warning has started it is
important to replace the batteries immediately to avoid any issues. Note: replacing or
removing the batteries does not affect the lock memory.
Keycard Control:
Keycard control is important to maintain the integrity and security of the system. Each
Keycard has a unique serial number printed on the face. Each Keycard is labeled with
the type of Keycard (User, Office, Clear… etc.). Keycards and the serial numbers should
be logged. Each lock should have a database showing what Keycards/RCUs are
authorized and the serial numbers of each Keycard. System and management
Keycards- Programming, Clear, Register, Lockdown Cancel and Database Keycards-
should be controlled by the department or person in charge of security. It is
recommended that these Keycards be placed in a secure location to prevent any
unauthorized use. It is important to report any lost or stolen Keycards and RCUs
immediately and take the action necessary to reinstate new Keycards and RCUs.
Swiping and holding the Keycards:
Swiping a RFID Keycard in this context means placing the Keycard flat on the reader in
front of the lock. It is recommended that the Keycard is placed so that the Keycard
essentially covers the reader. This will ensure proper transfer of data and reduce
programming errors. The Keycard should be left on for about 1 second or until the
confirmation (“beeps”) is heard. In some cased the Keycard needs to be held- usually
the Database Keycard- in order to ensure all the data is transferred. After the data
transfer is complete there is a second confirmation (“beeps”).
Troubleshooting:
If you have any issues please contact technical support (phone number and website is
listed on all the Keycards).
Some information and quick fixes:
Look on YOUTUBE for videos in regard to programming and troubleshooting (keywords-
Townsteel and RFID lock).
In general- if you receive 3 “beeps” after swiping the Keycard it is not valid or the
programming was incorrect.
When having issues- stop and read the Programming Manual.
When Initializing the lock- use the Programming, Clear and Register Keycards (in that
order) and do not stop in the middle- complete this sequence.
The Progamming and Clear modes last for 8 seconds after the last valid card was
swiped- let it timeout before attempting something different.
- 10 -
An Intelligent Security Alarm Door Locking System Rev. Oct. 29, 2014
User’s Manual The Security Door Lock XC /XM
Read the manual before programming, have all the Keycards and RCUs organized and
ready.
Check the Quick Start Guide for an easy (less wordy) method.
FCC STATEMENT:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.