Orientalmotor FPW540A2 U, FPW425A2 U, FPW425A2 J, FPW540A2 J, FPW560A2 J Operating Manual

...
HM-9211-2
OPERATING MANUAL
FPW Series
Dust Resistant, Water Tight Motors
Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety precautions.
Please read it thoroughly to ensure safe operation. Always keep the manual where it is readily available.
(Induction Motors)
Introduction
Before using the motor
Only qualified personnel should work with the product. Use the product correctly after thoroughly reading the section “Safety precautions”. Should you require the inspection or repair of internal parts, contact the Oriental Motor office where you purchased the product. The product described in this manual has been designed and manufactured for use in general industrial machinery, and must not be used for any other purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused through failure to observe this warning.
Standard and CE marking
Motors are recognized by UL and certified by CQC. Recognized name and certified name are motor model name. Voluntary display of the CE mark conforming to the Low Voltage Directives.
Standards
UL 1004, UL 2111, CSA C22.2 No.100, CSA C22.2 No.77, IEC 60529, IEC 60034-5, GB 12350
Standards File No.
UL File No.E64197, UL File No.166348 (Degree of protection), CQC
Applications for standard
EN 60034-1, EN 60034-5, IEC 60664-1
Installation conditions
Overvoltage category II, Pollution degree 3, Class I equipment (For EN/IEC Standards) When the machinary to which the motor is mounted requires overvoltage category III specifications, connect to power supply via an isolation transformer.
Standards for accessories
Capacitor: UL File No.E83671 (CYWT2), VDE License Nos.112847
(capacitors with a rated voltage of 250 VAC), 114747 (capacitors with a rated voltage of 450 VAC)
Capacitor cap: UL File No.E56078 (YDTU2)
Hazardous substances
RoHS (Directive 2002/95/EC 27Jan.2003) compliant
Safety precautions
The precautions described below are intended to prevent danger or injury to the user and other personnel through safe, correct use of the product. Use the product only after carefully reading and fully understanding these instructions.
Note
Handling the product without observing the instructions that accompany a “Warning” symbol may result in serious injury or death.
Handling the product without observing the instructions that accompany a “Caution” symbol may result in injury or property damage.
The items under this heading contain important handling instructions that the user should observe to ensure safe use of the product.
Do not use the product in explosive or corrosive environments,
in the presence of flammable gases, in water, or near combustibles. Doing so may result in fire, electric shock or injury.
Assign qualified personnel the task of installing, wiring,
operating/controlling, inspecting and troubleshooting the product. Failure to do so may result in fire, electric shock or injury.
Do not transport, install the product, perform connections or
inspections when the power is on. Always turn the power off before carrying out these operations. Failure to do so may result in electric shock.
Turn off the power in the event the overheat protection device
(thermal protector) is triggered. Failure to do so may result in injury or damage to equipment, since the motor will start abruptly when the overheat protection device (thermal protector) is automatically reset.
To prevent the risk of electric shock, use the motor for class I
equipment only. Motore zur Verwendung in Geräten der Schutzklasse I.
When installing the motor, ground the motor using a protective
grounding wire. Failure to do so may result in electric shock.
Erden Sie den Motor bei der Installation mit einem Schutzerdungskabel. Nichtbeachtung dieses Hinweises könnte einen elektrischen Schlag verursachen.
If the product is used in a place where it may come in contact
with water during operation, provide an earth leakage breaker. Failure to do so may result in electric shock.
Keep the input-power voltage within the specification to avoid
fire and electric shock.
Connect the cables securely according to the wiring diagram in
order to prevent fire and electric shock.
Do not forcibly bend, pull or pinch the cables. Doing so may
result in fire and electric shock.
Be sure to insulate the connection terminal of the capacitor.
Failure to do so may result in electric shock.
Turn off the power in the event of a power failure, or the motor
will suddenly start when the power is restored and may cause injury or damage to equipment.
Do not touch the connection terminal of the capacitor
immediately after the power is turned off (for a period of 30 seconds). The residual voltage may cause electric shock.
Do not disassemble or modify the motor. This may cause
electric shock or injury.
Do not use the motor beyond its specifications, or electric
shock, injury or damage to equipment may result.
Do not touch the motor during operation or immediately after
stopping. The surface is hot and may cause a burn.
Do not hold the motor output shaft or motor cable. This may
cause injury.
Keep the area around the motor free of combustible materials
in order to prevent fire or a burn.
1
To prevent the risk of damage to equipment, leave nothing
around the motor that would obstruct ventilation.
To prevent bodily injury, do not touch the rotating parts (output
shaft) of the motor during operation.
When an abnormality is noted, turn off the power immediately,
or fire, electric shock or injury may occur.
The motor’s surface temperature may exceed
70 °C, even under normal operating conditions. If a motor is accessible during operation, post the warning label shown in the figure in a conspicuous position to prevent the risk of
Warning label
burns.
To dispose of the motor, disassemble it into parts and
components as much as possible and dispose of individual parts/components as industrial waste.
Preparation
Checking the product
Upon opening the package, verify that the items listed below are included. Report any missing or damaged items to the branch or sales office from which you purchased the product.
Motor .................................. 1 unit
Capacitor............................. 1 piece (only for single-phase motors)
Capacitor cap ...................... 1 piece (only for single-phase motors)
Operating manual................ 1 copy
Set of mounting bolts.......... 1 set
(Mounting screws, Nuts, Washers 4 pieces each, Key 1 piece)
Checking the model name
Check the model number against the number indicated on the product.
100 V/110 V/115 V type
Model Motor model Capacitor model
FPW425A2-J FPW425A2- CH80CFAUL2
FPW425A2-U FPW425A2- CH65CFAUL2
FPW540A2-J FPW540A2- CH110CFAUL2
FPW540A2-U FPW540A2- CH90CFAUL2
FPW560A2-J FPW560A2- CH180CFAUL2
FPW560A2-U FPW560A2- CH120CFAUL2
FPW690A2-J FPW690A2- CH250CFAUL2
FPW690A2-U FPW690A2- CH180CFAUL2
200 V/220 V/230 V type
Model Motor model Capacitor model
FPW425C2-J FPW425C2- CH20BFAUL
FPW425C2-E FPW425C2- CH15BFAUL
FPW540C2-J FPW540C2- CH30BFAUL
FPW540C2-E FPW540C2- CH23BFAUL
FPW560C2-J FPW560C2- CH40BFAUL
FPW560C2-E FPW560C2- CH30BFAUL
FPW690C2-J FPW690C2- CH60BFAUL
FPW690C2-E FPW690C2- CH45BFAUL FPW425S2- FPW425S2- FPW540S2- FPW540S2- FPW560S2- FPW560S2- FPW690S2- FPW690S2-
The gear ratio appears at the model number indicated by the box ().
Installation
Location for installation
Install the motor in a well-ventilated location that provides easy access for inspection. The location must also satisfy the following conditions:
Indoors
Operating ambient temperature
10 to +40 °C (+14 to +104 °F) (non-freezing)
10 to +50 °C (+14 to +122 °F) for 100 V/200 V
Area that is free from an explosive atmosphere or toxic gas (such as
sulfuric gas) or liquid
Area not exposed to direct sun
Area free of excessive salt
Area not subject to continuous vibration or excessive shocks
Area free of excessive electromagnetic noise (from welders, power
machinery, etc.)
Area free of radioactive materials, magnetic fields or vacuum
1000 m or less above sea level
How to install the motor
Drill holes in the mounting plate and fasten the motor to the mounting plate with screws, nuts, and washers. Be sure that no gaps are left between the gearhead pilot section of the mounting plate. The maximum plate thickness applicable when the supplied screws are used is 10 mm (0.39 in.).
Installation holes
Model
FPW
425
FPW
540
FPW
560
FPW
690
Installation hole dimensions
[mm (in.)]
ØA ØB C 4-ØD
94
(3.70)
104
(4.09)
104
(4.09)
120
(4.72)
34
(1.34)
36
(1.42)
34
(1.34)
42
(1.65)
15
(0.59)
18
(0.71)
18
(0.71)
20
(0.79)
Note
ØB indicates the external dimension of the gearhead boss. Provide a hole with a sufficient allowance.
Washers
Nuts
Motor
Mounting plate
Screws provided with motor
Mounting screws
Model
FPW425 M5 P0.8 80 (3.15) 3.8 33
FPW540 M6 P1.0 90 (3.54) 6.4 (56)
FPW560 M6 P1.0 90 (3.54) 6.4 (56)
FPW690 M8 P1.25 100 (3.94) 15.5 (137)
Size of mounting screws
Thread size Length [mm (in.)]
Note
Do not disassemble the gearhead from the motor. Be sure to use the supplied screws and tighten within the
specified torque in order to ensure proper water proof fit.
ØB
ØA
5.5
(0.22)
6.5
(0.26)
6.5
(0.26)
8.5
(0.34)
4-ØD
C
Size of key
[mm (in.)]
4×25
(0.1575×0.984)
4×25
(0.1575×0.984)
5×25
(0.1969×0.984)
6×25
(0.2362×0.984)
Tightening
torque
[N·m (lb-in.)]
2
Loading...
+ 2 hidden pages