Oregon BAR112 USER MANUAL

DIGIT AL WEATHER FORECASTER
WITH REMOTE THERMO-HYGRO
SENSOR AND RADIO CONTROLLED
CLOCK
MODEL NO.: BAR112HGA
USER’S MANUAL
Congratulations on your purchase of the Weather forecaster with cable free sensor and radio-controlled calendar clock BAR112HGA.
This unit has a large four-line liquid crystal display (LCD) for
displaying weather forecast information, in/outdoor temperatures
and relative humidity, radio frequency (RF) controlled calendar
clock and daily alarm. Also, the main unit can support up to three remote sensors.
Other features include day of week display in three abbreviated languages, crescendo alarm, and interchangeable clock display modes.
GB
MAIN FEA TURES: MAIN UNIT
A
A1
B C
D EF
MAX
MAX
433MH CABLE FREE
Z
TEMP
RH
1
1
CHANNELMEMMODE / SET
CHANNELMEMMODE / SET
J
I H G
K
L M N
MODEL N O. BAR112H GA
RESET
Tested To Comply With FCC Standards
FOR H O ME OR OF F ICE U SE
O
P Q
R
S
T
1
GB
A . FRONT DISPLAY
A four line easy-to-read LCD
A1. WEATHER FORECAST WINDOW
Graphically illustrates a weather forecast
B. [ ] BATTERY-LOW INDICATOR
Activates when the remote-sensor or main unit battery power is low
C. [ ] RADIO-RECEPTION SIGNAL
Indicates the condition of radio reception
D . [ MODE/SET ] BUTTON
Changes the display mode of the clock and alters time/date setting
E. [
] BUTTON
Displays the alarm time or changes the alarm set time
F. [ MEM ] BUTTON
Displays minimum and maximum temperature and humidity readings and erases memory data
G. [ CHANNEL ] BUTTON
Toggles between the remote sensor channels
H. [ ((.)) ] ALARM ICON
Appears when the alarm time is displayed
1
I. [
] ALARM-ON ICON
Appears when the alarm is activated
J. US - TIME ZONE MAP ICON
Displays Pacific (P), Mountain (M), Eastern (E) or Central
(C) time-zone
K. WALL-MOUNT HOLE
For mounting the unit on a wall
TEMPERATURE & RELA TIVE HUMIDITY ALARM :
( for Channel - 1 only ) L. [ ON/OFF ] BUTTON
Enables / disables HI/LO temp alarm and HI/LO % RH alarm
M. [ HI/LO ] BUTTON
- Set the upper or lower temperature and humidity alarm limits
- Confirms alarm settings
N. [ s ] BUTTON
Advances the value of the settings for the HI/LO temperature and humidity alarm
CLOCK : O. [ s ] BUTTON
Advances the value of a setting
P. [ AL ON/OFF] BUTTON
Enables or disables the daily alarm
Q. [ ZONE ] BUTTON
Toggles between the 4 US time-zones : Pacific, Mountain, Eastern or Central
R. [ RESET ] BUTTON
Returns all settings to default values
S. BATTERY COMP ARTMENT
Accommodates four (4) UM-3 or “AA” size batteries
T. REMOV ABLE TABLE ST AND
For standing the main unit on a flat surface
2
FEATURES: REMOTE THERMO-HYGRO
SENSOR
A. TWO-LINE LCD
Displays the current temperature and humidity monitored by the remote unit
B. LED INDICA TOR
Flashes when the remote sensor transmits a reading
C. °C/°F SLIDE SWITCH
Selects between Centigrade (°C) and Fahrenheit (°F)
D . CHANNEL SLIDE SWITCH
Select the remote sensor Channel 1, Channel 2 or Channel 3
E. RESET
Returns all user programmed settings to original factory set
values
F. BATTERY COMP ARTMENT
Accommodates two (2) UM-3 or AA-size batteries
G. BATTERY DOOR H. WALL-MOUNT HOLDER
Supports the remote unit in wall-mounting
I. REMOVABLE T ABLE ST AND
For standing the remote unit on a flat surface
BEFORE YOU BEGIN
For best operation,
1. Assign different channels to different remote units.
2. Insert batteries for remote units before doing so for the main unit.
3. Place the main unit as close as possible next to the remote unit, reset the main unit after installing batteries. This will ensure
3
GB
GB
easier synchronization between the transmission and reception of signals.
4. Position the remote sensor and main unit within effective transmission range, which, in usual circumstances, range of 100
feet (30 meters) under ideal conditions.
Note that the effective range is vastly affected by the building
materials and where the main and remote units are positioned. Try various set-ups for best result.
Though the remote sensors are weather resistant, they should be placed away from direct sunlight, rain or snow.
BATTER Y INST ALLA TION: MAIN UNIT
1. Gently lift up the tab on the battery compartment door.
2. Insert four (4) UM-3 or “AA” size batteries.
3. Replace the battery compartment door.
BATTER Y AND CHANNEL INST ALLA TION:
REMOTE UNIT
The remote thermo-hygro sensor unit uses two (2) UM-3 or “AA
size batteries.
Follow these steps to install / replace batteries:
1. Remove the screws on the battery compartment.
2. Select the channel number on the [CHANNEL] slide switch.
3. Select the temperature display unit on the °C/°F slide switch.
4. Insert the batteries strictly according to the polarities shown therein.
5. Replace the battery compartment door and secure its screws.
Replace the batteries when the low-battery indicator of the particular channel lights up on the main unit. (Repeat the steps described in section “BEFORE YOU BEGIN”)
Note that once a channel is assigned to a remote unit, you can only change it by removing the batteries or resetting the unit.
4
LOW BATTER Y W ARNING
When it is time to replace batteries, the low-battery indicator will be displayed for the selected channel.
HOW TO USE THE T ABLE ST AND OR WALL
MOUNTING
The main unit has a removable table stand which when connected can support the unit on a flat surface. Or you can remove the stand
and mount the unit on a wall using the recessed screw hole.
The remote sensor comes with a wall mount holder and a table stand.
Main unit
Wall-mount Table Stand
MAX
TEMP
RH
MAX
1
1
CHANNELMEMMODE / SET
433MH CABLE FREEZ
Remote unit
GB
Wall-mount Table Stand
THE RESET BUTTON
This button is used when the unit is operating in an unfavorable way or malfunctioning. To return all user programmed settings to their original factory values, press [ RESET ] by using a blunt stylus to hold down the button.
GETTING STA RTED
Once batteries are placed in a given remote sensor unit, it will start transmitting information at 40-second intervals.
For approximately a 3-minute duration, the main unit will
automatically search for signals once batteries are installed. Upon successful reception, the individual channel temperature reading will be displayed on the second line and the respective humidity reading on the third line. The main unit will automatically update its readings at about 40-second intervals.
5
Loading...
+ 10 hidden pages