Ventilated Absorbers - AEPV Series
Ventilated absorber
> Applications:
• Chamber HVAC systems where air passage is critical
• Medium power applications
> Key features:
• Allows air to move freely through absorber
> Shape:
• Pyramidal
• Wedge
• Flat
> Frequency band:
• From 125 MHz to 18 GHz
> Standard base size:
• 2’ x 2’ (60.96 cm x 60.96 cm)
Adapted Absorbers
> Height:
• 4’’ to 72’’ (10.2 cm to 121.9 cm)
> Operating conditions:
• Temperature: 70º F +/- 10º (21º C +/- 3º)
• Relative humidity: 55 % RH +/-15 %
> Indoor/outdoor:
• Indoor
> Related certifications:
• NRL 8093 – 1, 2, 3
> Ordering code:
• AEPV-XX, where XX designates absorber
height in inches
27
1/ Description
Ventilated absorbers are manufactured from special reticulated (open cell) foam. When used as a vent material, this
product allows air to move freely.
2/ Specifications
AEPV-4 AEPV-6 AEPV-8 AEPV-12 AEPV-18 AEPV-24 AEPV-36 AEPV-48
Height in 4 6 8 12 18 24 36 48
cm 10.2 15.2 20.3 30.5 45.7 61 91.4 121.9
Pyramids per block 144 64 64 36 16 9 4 4
@ 125 MHz dB 28
@ 250 MHz dB 30 32 35
@ 500 MHz dB 30 35 37 40
@ 1.0 GHz dB 30 35 37 40 45 45
@ 3.0 GHz dB 30 33 37 40 45 45 50 50
@ 6.0 GHz dB 35 37 45 45 50 50 50 50
@ 10.0 GHz dB 40 40 50 50 50 50 50 50
@ 15.0 GHz dB 45 50 50 50 50 50 50 50
Absorption @ Normal Incidence
@ 18.0 GHz dB 50 50 50 50 50 50 50 50
Power Watt/in2 1 1 1 1 1 1 1 1
Watt/m2 1550 1550 1550 1550 1550 1550 1550 1550
Weight lbs/pc. 2.5 3.5 4.5 6.5 8 11.5 16 22
kg/pc. 1.1 1.6 2 2.9 3.6 5.2 7.3 10
3/ Medium Power Absorber Specifications
When the material is used as a medium power absorber,
it can safely dissipate 1 W/in2 CW with standard convection cooling. This is accomplished by the open cell characteristics of the reticulated foam, which increases the
ability of the absorber to dissipate the heat generated
by the absorption of the microwave energy. For higher
power applications of 2 - 3 W/in2 CW, material must be
force-cooled.
4/ Pressure Drop Specifications
HVAC professionals use pressure drop calculations to
ensure adequate air flow for proper air turn-over within
a chamber.
AEPV-18 mechanical drawing
18’’
6’’
24”
24”
3’’
28