Oransi OVHP44, V-hepa Plus OVHP44 User Manual

Part#: OVHP44
V-hepa Plus
www.sylvane.com 1-800-934-9194
Table of Contents:
Safety Instructions 1
Know Your Air Purifier 2
Functions 2
Assembly and Maintenance 3
Cleaning and Maintenance 3
How to Remove the Cover 4
How to replace the UV Lamp 4
Safety Instructions:
WARNING: RISK OF ELECTRICAL SHOCK Safety precautions should always be used when operating this or any electrical appliance. Decrease the risk of electrocution, electric shock, injury or fire by reading and following all of the warnings below. To reduce the risk of electric shock, do not attempt to service the air purifier in any way other than to replace or clean the air filter. Read all instructions before operating the air purifier. This product operates at 115V AC, 60Hz only. Do not run the power cord under carpets, and do not cover with throw rugs. This product is not intended to filter oil or grease from air. Always unplug the power cord from the electrical outlet when the air purifier is not in use or when changing the filter. Never run the air purifier unless it is fully assembled. Do not alter the plug in any way. Always turn the manual control knob to the off position before unplugging the air purifier from outlet. Do not place the cord near a heated surface. Never operate the air purifier if the plug or cord is damaged or appears damaged. Only qualified service personnel should ever replace or attempt to replace a damaged power cord. Never use the power cord to pick up, carry, drag, pull, or lift the air purifier. Do not pull the cord against or around sharp corners and edges. Always remove the plug from its power outlet by holding onto the plug itself and pulling gently. Never pull on the cord itself to unplug it from its power outlet. Use care when operating the air purifier by keeping all foreign objects, fingers, body parts, hair, loose clothing and jewelry away from openings. Never touch the air purifier or its plug when your hands are wet.
www.sylvane.com 1-800-934-9194
Know Your Air Purifier:
Functions:
1. Washable pre-filter to capture large particles such as dust.
2. HEPA filter to remove microscopic particles down to 0.3 microns in size such as fine dust, smoke, pollen, bacteria and mold.
3. Low level and ozone safe negative ionizer to freshen and balance the air(ie neutralize a surplus of positive charges from Tv s and computer monitors).
4. Photocatalyst filter (TiO2): Photocatalytic oxidation is achieved when you combine UV rays with a Titanium Dioxide (TiO2) coa ted filter. This process creates hydroxyl radicals that remove harmful gases and VOC s (volatile organic compounds) such as formaldehyde, ammonia and many other common contaminants that are released by building materials, household cleaners, particle boards and carpeting.
5. UV-C lamp. Ultraviolet light possesses just the right amount of energy to break organic molecular bonds. As microorganisms pass by the UV rays this bond breakage translates into cellular or genetic damage to microorganisms such as germs, viruses and mold resulting in their destruction. 6 Three fan speed.
Assembly and Maintenance:
1.The washable pre-filter can be separated from the HEPA filter and cleaned with water or a low level suction vacuum cleaner. This is suggested every couple months if you have pet hair or above average dust levels.
2.The HEPA filter cannot be washed and the media in the filter will be damaged if it becomes wet.
3. If the air purifier begins to make a noise like the motor is straining due to increased air flow resistance it is best to replace the HEPA filter since the air flow through the air purifier is being greatly reduced.
UV Lamp
Front case
Pre-filter+Hepa filter
Main unit
Ionizer
TiO2 filter
Electric User Interface:
S
p
e
e
d
2Hr
8Hr
4Hr
n
o
I
/
V
U
r
e
T
i
m
Power
1. Press center button to turn on/off air purifier.
2. Air purifier will start on the medium fan speed with the UV/ion on.
3. Pressing the speed button will cycle the fan to high speed(red) ­ low speed(green) - medium speed(yellow)
4. Pressing the timer button will cycle between 2 Hours, 4 Hours, and 8 Hours setting. Once the selected time has passed, the air purifier will automatically turn off.
www.sylvane.com 1-800-934-9194
Pull back
Lift up
B.Push towards the unit body
A. Insert base of front cover
How to Remove the Cover:
1. Make sure the air purifier is turned off and unplugged.
2. Grab the cover near the top and pull toward you as shown below.
3.Clean or replace the filter. When placing the filter back into the air purifier ensure the black pre-filter side is facing towards you.
4.To re-install the front cover, place the bottom of the cover into the slots at the base of the air purifier first and then pivot the cover until the magnets near the top lock the cover in place.
How to replace the UV Lamp
1.Caution do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness of the lamp.
2.To remove the lamp, ensure the air purifier is unplugged and the UV lamp has been off for at least 15 minutes. Remove the front cover and all of the filters. Hold the white ceramic ends of the UV lamp and turn 90 degrees counter clockwise.
3.To install the lamp, hold the white ceramic ends, insert the copper pins into the UV lamp assembly and turn 90 degrees clockwise. Reinstall the filters and close the front cover.
www.sylvane.com 1-800-934-9194