This guide describes the minimum steps you must perform to power on and boot your server for the first time.
Before installing the SPARC Enterprise M3000 server, check for late-breaking information about patches and
known issues. Information found in the
supersedes the information in this document.
Before performing an installation, refer to the following documents for safety information regarding the SPARC
Enterprise M3000 Server:
■Important Legal and Safety Information – Printed document included in the ship kit.
■SPARC Enterprise M3000 Server Safety and Compliance Manual – Available online at the documentation web
site.
Prepare the Site for Installation
1. Verify power, air conditioning, and floor area requirements.
See the SPARC Enterprise M3000 Server Site Planning Guide.
2. Check the delivered items against the “LIST OF ATTACHMENT” that came with the server.
Register the System
1. Locate the serial number for your system or the customer information sheet that came with the system.
2. Go to the following web site to register your system:
http://www.sun.com/service/warranty/index.xml#reg
1
Page 2
Install Optional Components
Before installing the server into the rack, you must first install any optional components that you ordered with
the server, such as DIMMs, PCIe cards, and so on. Refer to the SPARC Enterprise M3000 Server Service Manual for
the instructions on installing optional components.
Mount the System In a Rack
For rackmounting instructions, refer to the instructions in the SPARC Enterprise Rack Mounting Guide (online)
and the Rail Kit Instructions which ships with the rails.
Installation Steps for the SPARC Enterprise M3000 Server
For quick installation and configuration, follow these steps. For more detailed information, see the SPARC
Enterprise M3000 Server Installation Guide.
Caution – Make sure that the AC power source circuit breaker is in the OFF position before
connecting the AC power cords.
▼ Connect the Cables
1. Connect the power cords to the power supply units on the rear panel of the server.
2. Connect the power cords to the AC power supply system.
This server is shipped with grounding-type (three-wire) power cords. Always connect the power cords into
grounded power outlets.
FIGURE 1 Rear Panel of the Server
1234
5
Figure Legend
Location NumberComponent
1Power supply unit
2PCIe slot
3Serial port (for XSCF)
4LAN port (for XSCF)
5Gigabit Ethernet (GbE) port (for OS)
2
Page 3
3. Use the RS232C cable (serial cable, RJ-45 to DB-9) supplied with the server in the Accessory Kit, and
connect the administration console to the serial port (see
FIGURE 1, #3) on the rear panel of the server.
You can use any of the following devices with a DB-9 serial port as the administration console: ASCII
terminal, workstation, terminal server (or a patch panel connected to a terminal server), or personal
computer. A Serial-to-USB port adapter may be required for laptops.
▼ Initialize the XSCF
The following steps will log in to the XSCF Shell and initialize the XSCF settings. XSCF is a system control
facility to set up and control the server.
1. Set the mode switch on the operator panel to the Service mode ().
The key for the operator panel is supplied with the server.
FIGURE 2 Operator Panel
1
2
3
4
5
Figure Legend
Location No.Name
1POWER LED
2XSCF STANDBY LED
3CHECK LED
4Power button
5Mode switch (Key switch)
2. Turn the AC power source circuit breaker to "ON".
After AC power is turned on, the server starts the XSCF initialization that can take up to 5 or more minutes.
When the initialization completes, the XSCF STANDBY LED () on the operator panel lights.
3. After the XSCF initialization completes, enter default at the login prompt.
login: default
3
Page 4
4. Operate the mode switch within one minute according to the messages to change the mode switch.
A login authentication timeout will occur after one minute.
Change the panel mode switch to Locked and press return...
Leave it in that position for at least 5 seconds.
Change the panel mode switch to Service, and press return...
5. Confirm that the XSCF Shell prompt is displayed on the administration console.
XSCF>
6. Initialize the XSCF settings. The following are the required settings for installation.
SettingsCommand
Registration of an XSCF user account, password, and user privileges
Registration of a user account of a field engineer (FE) (for maintenance)
Date and time settingssetdate, settimezone
Confirmation of the XSCF host public keyshowssh
SSH/telnet settingssetssh, settelnet
Network interface, routing, and DNS-related settings
Domain-SP Communication Protocol (DSCP) settings
Altitude administration setting
Dual power feed option settingsetdualpowerfeed
* To apply the settings, the XSCF unit must be reset with the applynetwork and rebootxscf commands.
† Toapply the settings, the XSCF unit must be reset with the rebootxscf commands.
‡ Toapply changes made with the setdualpowerfeed command, power to the server must be completely disconnected and then
reconnected (all power cords must be disconnected and then reconnected). Waitat least 30 seconds before reconnecting the power cords to
the server.
‡
*
†
adduser, password,
setprivileges
setnetwork,setroute,
setnameserver etc.
setaltitude
For details on the setting procedure, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User’s Guide.
7. Log in to the XSCF Shell with the user account and password that were set in Step 6.
▼ Power On the Server
1. The following steps will power on the server.
a. Confirm that the mode switch on the operator panel is set to the Service mode ().
b. From the XSCF Shell, enter the following console command:
XSCF> console -d 0
Connect to DomainID 0?[y|n] :y
This switches you from the XSCF Shell to the domain console.
c. Confirm that the XSCF STANDBY LED () on the operator panel is on.
4
Page 5
d. Push the Power button () on the operator panel to power on the server.
The server starts and begins a self-diagnosis. Confirm that no error messages are displayed on the
administration console during the boot process.
e. Confirm that the POWER LED () on the operator panel is turned on.
f. Confirm that ok prompt is displayed on the domain console.
The ok prompt is displayed after the self-diagnosis completes.
g. Press the Enter key, and then press the "#" and “.”(period) keys.
This switches you from the domain console to the XSCF Shell.
h. From the XSCF Shell, execute the fmdump command or showlogs command, and confirm that no
errors are found.
2. Connect the system control network to a LAN port (see
FIGURE 1, #4) on the rear panel of the server with
an Ethernet cable.
3. Verify the hardware configuration by using the following commands on the administration console
connected to the system control network.
CommandPromptDescription
showhardconfXSCF ShellAll the components installed in the server and their statuses are displayed.
Confirm that no asterisk (*) is displayed in front of any FRUs.
showhardconf -uXSCF ShellCheck the number of FRUs mounted on the server against the “PRODUCT
TEST RECORD“ that came with the server.
probe-scsi-allok PromptConfirm that the CD-RW/DVD-RW drive unit and hard disk drive
installed in the server are recognized.
show-devsok PromptConfirm that each installed PCIe card is recognized.
To switch from the XSCF console to the ok prompt, enter the console -d 0 command. To switch from the
ok prompt to the XSCF console, press the enter key, and then press the "#" and "." (period) keys.
4. Install additional hardware or peripheral devices. If not needed, proceed to the Step 5.
For details on how to add optional devices, such as additional memory or an additional PCIe card, see the
SPARC Enterprise M3000 Server Service Manual. To add an additional storage device or other peripheral
device, see the manual supplied with the device.
5. The following steps will connect the domain to the user network. If you isolate the domain from the
network, proceed to the Step 1.
The user network is a network which enables users to access the domain.
a. Connect one end of an Ethernet cable to a GbE port (for the OS) (see
the server.
You can connect the Ethernet cable to a GbE port (for the OS) or to the LAN port on a LAN card mounted
in a PCIe slot (see
FIGURE 1, #2).
b. Connect the other end of the Ethernet cable to the customer ’s network environment.
▼ Boot the Oracle Solaris Operating System
1. The following steps will boot the Oracle Solaris Operating System.
The Oracle Solaris OS is preinstalled in the slot 0 of the hard disk drives.
FIGURE 1, #5) on the rear panel of
5
Page 6
a. From the ok prompt of the domain console, execute the boot command.
ok boot
b. After the login prompt is displayed, log in with root account.
2. Confirm the status of hardware operations and device connection by using the Oracle VTS software.
For details, see the Oracle VTS user’s guide.
3. Make the initial settings for the domain.
For details, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Administration Guide.
SPARC Enterprise M3000 Server Related Documentation
System Planning and Site Preparation• SPARC Enterprise M3000 Server Overview Guide
• SPARC Enterprise M3000 Server Site Planning Guide
System Installation• SPARC Enterprise Equipment Rack Mounting Guide
• SPARC Enterprise M3000 Server Installation Guide