Opzoon Technology OPM1AA001 Users Manual

Manual
Outlook
DC12V socket
IO
interface
UART
Microphone
DC12V socket
IO interface
RJ45
Power switch
Front cover
Negative power
Positive power
R_OFF R_COM R_ON
GND
W_OD1 W_OD0
GND
W_ID1 W_ID0
Rear cover
Installation Guide
Install the fixing hole
Decorative articles
doors backplane
Decorative articles
1. According to the rear cover size and fixed hole position, the
rectangular groove and 4 fixed holes (diameter 8mm depth 45mm) are opened in the installation position in connection with the actual situation.
2. Remove the front cover fixing screws and slide the front cover upward. Secure the device to the backplane with 4 sets of screws (M4 * 14) and nuts (M4 * 7 * 3.2), then replace the front cover and secure
the screws.
3. Connect the cable to the device.
4. Secure the device to the wall with four sets of expansion bolts (M4 * 40) through the back panel, then affix the trim.
Product Specification
Product model
Facial anti-counterfeit
Recognition distance
Recognition mode
Ambient light range
Processor
Memory
Flash
Camera
Display
Ambient temperature
Power
Dimenstion
WIFI
Bluetooth
Wiegand input
Wiegand output
Relay
Netword port
UART
USB
OTG
Debug
DC
OFR-T1-M
Support
60 ~ 90 cm
1 : N , 1 : 1 , 1:1 / 1:N
0 ~ 800LUX(Camera lens should be avoided from the
direct sunlight)
2.1GHz quad-cord CPU plus 192-cord GPU
2GB DDR3 RAM
16GB(scalable)
Dedicated binocular camera (visiable light and near-infarad lens)
8.0" IPS LCD touch screen
0℃ ~ 45℃
12V 4.16A Max
123 x 165.71 x 320.61 mm (L x W x H)
Support
Support
1,W_ID0/W_ID1/GND
1,W_OD0/W_OD1/GND
1,R_ON/R_COM/R_OFF
1
1
2
1
1
1
Opzoon Technology Co.,Ltd.All rights reserved.400-706-8366 global.surport@opzoon.com www.opzoon.com
Manual
Welcome
Press the power button boot device, "Wizard" will guide you through a few simple steps to set up your device. You can connect to the Internet through WLAN or wired network, press the "Wizard" to complete the
activation device.
You need to register an account on the "Opzoon facial recognition cloud management platform" (https://www.opzoonface.com). Login
account, will be able to perform remote configuration management, decentralization of authority, distribution of content and business rules.
[Note] If you do not activate the device, the device can only use the basic functions, business functions can not be used "Opzoon facial recognition cloud management platform" provides.
Device Managment
Administrators can screen device by clicking the "Management" button, validated, enter the management interface. Standalone mode is provided in the apparatus to complete the relevant management interface; Network mode version can be done by setting the management platform or App.
<
情景选择
Biopsy threshold setting
In vivo detection of visible light threshold (The large the value,the more stringent)
Near infrared threshold
(The large the value,the more stringent)
Face recognition threshold setting
Visible light threshold (The similarity is greater than this value)
Near infrared threshold
(The similarity is greater than this value)
人脸识别设置
Parameters Configuration
快速情景 适合人流量大且快速通过
30%
0% 100%
50%
0% 100%
60%
0%
20%
0%
CANCEL OK
100%
100%
Face recognition is set according to the general usage scenarios, we offer a default option for you to choose to use. You can also according to different usage scenarios, manually set the scene and face
Saturday
Place IC ID Card
recognition mode, flexible and controllable.
After the "Getting Started", enjoy the elegance of face recognition
service.
Software Upgrade
Copy the downloaded firmware to a USB disk and insert USB drive machine, device management, firmware upgrade click, select USB drive firmware, click on "Enter Upgrade", then the device will automatically complete the firmware upgrade.
Setting
Device Recognition Set ID face comparison
Date or Time Display Setting Speaker Setting
Memory Usage Reboot Factory Default
Firmware Upgrade Administrator Period
Rule Internet Setting
Standby Advertising
Select File
Firmware Upgrade
ENTER UPGRADE
More Information
Security Information
Failure to comply with safety instructions may result in fire, electric shock, or other injury or damage to the product or other property. Nonstandard ground wire may be dangerous. Do not disassemble products and opening an enclosure itself. Non-professionals do not open, alter or repair the product.
Recycling and Environmental Protection Information
Based on "waste electrical and electronic product recycling regulations", when users no longer need the product, please observe local waste electrical and electronic products recycling-related laws and regulations, will have certified products to local recycling companies for recycling.
To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operations at closer than this distance is not recommended.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
—Consult the dealer or an experienced radio/ TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Opzoon Technology Co.,Ltd.All rights reserved.400-706-8366 global.surport@opzoon.com www.opzoon.com
Loading...