OPW M00-051.00 FSC3000 Command-line Configuration Manual

Page 1
Part Number: M00-051.00, Rev. 10
Issue Date: 9/5/17 Supersedes: 3/24/2017
M00-051.00 FSC3000
Fuel System Controller
Command-Line Configuration Guide
Page 2
Doc. No.: M00-051.00 Rev.: 10
Copyright Information
© 2016 Delaware Capital Formation, Inc. All Rights Reserved. DOVER and the DOVER logo are registered trademarks of Delaware Capital Formation, Inc., a wholly-owned subsidiary of Dover Corporation.
Contact OPW Fuel Management Systems
Visit us at www.opwglobal.com, or contact us at:
Call 1-877-OPW-TECH (877-679-8324) For calls outside US and Canada, call +1-708-485-4200 Fax 1-800-421-3297
Monday through Friday, 7 a.m. to 6 p.m., US CST
For technician registration, see
http://opwglobal.com/TechSupport/TechnicianRegistration.aspx.
Page 2 of 181
For in-depth training via OPW University, see
http://www.opwglobal.com/opw-u-training-registration.html.
NOTE: This configuration guide was created for the purpose of training and assisting
technicians on how to configure FSC3000™systems. All configuration values must be set up to meet the customer’s site conditions and/or needs. The technician should read the guide in its entirety.
IMPORTANT: The information in this Configuration Guide pertains to Software Version 1.12
and above. Older versions of the software may not support all features.
Page 3
Table of Contents
Doc. No.: M00-051.00 Rev.: 10
Page 3 of 181
Introduction
Section1 Getting Connected
1.1 Communication Parameters
1.2 Connection Methods
1.3 Additional ConnectionMethods
1.3.1 WiFi Modem
Section2 Passwords
2.1 Security Levels
2.1.1 Remote Access (Modem or Ethernet)
2.1.2 Partial Access (or “Main Password”)
2.1.3 User Access
2.1.4 Admin Access
2.2 Set Admin (Admin Login Required)
11
13
13
13
14
14
17
18
18
18
19
19
19
2.2.1 Create User
2.2.2 Delete User
2.2.3 Show User(s)
2.2.4 ChangePasswords
2.2.5 Clear Event Log
2.3 System Start
2.4 Password Recovery
2.5 Cold Start Procedure
Section3 Show Flags
Section4 Time Management
4.1 Set Time
19
20
20
20
20
20
20
21
23
25
25
Page 4
Doc. No.: M00-051.00 Rev.: 10
Page 4 of 181
4.2 Set Date
4.3 Set Time Change
4.4 Set System Time
4.5 Set Light
Section5 Fuel Types & Tank Setup
5.1 Fuel Types
5.1.1 Set Fueling Units
5.1.2 Set Fueltype
5.1.3 Set TieredDiscounts
5.1.4 Tiered Accounts
5.2 Tanks
5.2.1 Set Tank # (# = 1 to 8)
Section6 Pump Setup
25
25
25
25
27
27
27
27
29
34
37
37
39
6.1 MechanicalPumps
6.1.1 Configure PCT # (# = 1 to 8)
6.1.2 Configure PCT # POS # (PCT 1 to 8 andPOS 1 to 8)
6.1.3 Install PCT # POS # (PCT 1 to 8 and POS 1 to 8)
6.1.4 Install PCT # (# = 1 to 8)
6.2 Electronic Pumps Controlled by UPC
6.2.1 Configure PCT # (# = 1 to 4)
6.2.2 Configure PCT # POS #
6.2.3 Install PCT # POS # (PCT 1 to 4 and POS 1 to 8)
6.2.4 Install PCT # (# = 1 to 4)
6.3 Electronic Pumps Controlled by DPC (Wayne)
6.3.1 Install Program
39
39
40
40
40
41
41
41
41
42
43
43
Page 5
Doc. No.: M00-051.00 Rev.: 10
Page 5 of 181
6.3.2 Configure PCT # (# = 1 to 4)
6.3.3 Configure PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)
6.3.4 Install PCT # POS # (# = PCT 1 to 4 andPOS 1 to 8)
6.3.5 Install PCT # (# = 1 to 4)
6.4 Electronic Pumps Controlled by DPC (Gilbarco)
6.4.1 Install Program
6.4.2 Configure PCT # (# = 1 to 4)
6.4.3 Configure PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)
6.4.4 Install PCT # POS # (# = PCT 1 to 4 andPOS 1 to 8)
6.4.5 Install PCT # (# = 1 to 4)
6.5 Electronic Pumps Controlled by DPC (Gasboy)
6.5.1 Install Program
6.5.2 Configure PCT # (# = 1 to 4)
43
43
44
44
45
45
45
45
46
46
47
47
47
6.5.3 Configure PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)
6.5.4 Install PCT # POS # (# = PCT 1 to 4 andPOS 1 to 8)
6.5.5 Install PCT # (# = 1 to 4)
6.5.6 DPC – Gasboy Pump Mapping
Section7 Terminal Setup
7.1 OPW-FMS Fuel Island Terminals
7.1.1 Configure FIT # (1 to12)
7.1.2 Install FIT #(1to 8)
7.2 VIT (Vehicle Identification Terminal) – PetroLink™
7.2.1 Install VIT x (VIT 1 to 4)
7.2.2 Configure VIT # (# = 1 to 4)
7.2.3 Configure VIT # POS # (VIT 1 to 4and POS 1 to 8)
47
48
48
49
51
51
51
52
53
53
53
53
Page 6
Doc. No.: M00-051.00 Rev.: 10
Page 6 of 181
7.2.4 Install VIT # POS # (VIT 1 to4 and POS 1 to 8)
Section8 Display Prompts & Receipts
8.1 Dual Language
8.1.1 Set Language
8.2 Receipts
8.2.1 Format Receipt Header
8.2.2 Format Receipt Trailer
8.2.3 Format Receipt Body
8.2.4 Receipt Body Code Variables
8.3 Prompts
8.3.1 Standard Prompts
8.3.2 Format Display Default
8.4 FSC3000™ Default Display Prompts
53
55
55
55
55
55
56
56
57
58
58
58
59
8.4.1 Graphic Codes
8.4.2 Update Customized Picture Files in the FIT500™
8.4.2.1 Display Formatting Commands
8.4.2.2 Picture Codes
8.5 Additional Prompts
Section9 Download
Section10 Set Journal
Section11 Show Log (SavingLog)
Section12 FSC3000™ Memory Structure
12.1 Application Memory
12.2 Transaction Memory
12.3 Card/Account Memory
62
64
64
65
67
71
73
75
77
77
77
77
Page 7
Doc. No.: M00-051.00 Rev.: 10
Page 7 of 181
12.4 Set Card Buffer (option1) – Card/TransactionSize
12.4.1 Set Card Buffer (option 2) – Card/Account Options
12.4.2 Account #
12.4.3 Expiration Date
12.4.4 Monthly Allocation
12.4.5 Daily Allocation
12.4.6 PIN #
12.4.7 Save Odometer Entries
12.4.8 Odometer Reasonability
12.4.9 Product Restriction
12.4.10 Quantity Restriction
12.4.11 Driver/Vehicle/Account Name
12.4.12 Verify Prompts 1, 2, 3
78
79
79
80
80
80
80
80
81
81
81
82
82
12.4.13 Prompt-Sequence
12.4.14 Set Card Buffer (option 8) – Additional Options
Section13 Restrictions and Reasonability
13.1 Set Product Restriction
13.2 Set Quantity Restriction
13.3 Set Odometer Reasonability
Section14 Card/Account Management
14.1 Media Formats
14.2 Special Card Formats (Magnetic Cards)
14.3 Card/Account Adding/Modifying/Deleting
14.4 Card/Account Reports
Section15 Network Management
82
83
85
85
86
87
89
89
90
91
91
93
Page 8
Doc. No.: M00-051.00 Rev.: 10
Page 8 of 181
15.1 Processing of Cards to a Remote Host
15.1.1 UnderstandingBank Card Processing
15.2 Set Network (Admin Login Rights Required)
15.2.1 Set Time Zone (option 8)
15.2.2 Set Forced Trans CaptureTime (option11)
15.2.3 Print Price and Total on Network Receipts (option 13)
15.2.4 Configure Host Port(s) andDevices (option14)
15.3 Host Specific Setup Options
15.3.1 CFN
15.3.1.1 CFN Product Code Descriptions
15.3.2 Comdata (Terminal Fuelnetwork, dial-up only)
15.3.3 ComdataPOS
15.3.4 EFS (Original EFS host)
93
93
94
94
94
95
95
97
98
102
106
108
110
15.3.5 T-Chek
15.3.6 TCH
15.3.7 FleetOne
15.3.8 NBS\FMGC (Fuelman\Gascard [FleetCor])
15.3.9 NBS\BankCard & Quarels Fuel Network
15.3.10 Paymentech
15.3.11 Paymentech Petroleum Product Codes
15.3.12 Buypass
15.4 FleetTable
15.4.1 Network Specific Differences:
15.4.1.1 (0=Local)
15.5 ISO Table
112
114
116
118
121
125
132
134
137
140
142
142
Page 9
Doc. No.: M00-051.00 Rev.: 10
Page 9 of 181
15.5.1 Card Type Indicator
15.6 Set ISO - Buypass (Firstdata)
15.7 ComdataPOS
15.8 Set Fleet – ComdataPOS
15.9 Set ISO - ComdataPOS
Section16 TransactionManagement
16.1 Set Transaction
16.1.1 Wrap Around
16.1.2 Write Over NON-CAPTURED or FAILED Transactions
16.1.3 Redefine Transaction
16.1.4 Specified Display Fields
16.2 Transaction Reports
16.3 Transaction Searches
144
147
149
151
152
155
155
155
155
155
155
157
157
16.4 Transaction Searches (network)
16.4.1 Clearing Transactions
16.5 Pump & Fuel Reports
16.6 Transaction Terminations/Denials
16.6.1 Denial Codes (lower-case letter) – AuthorizationNever Granted
16.6.2 Termination Codes (upper-case letter) – AuthorizationGranted
16.6.3 Network “Unableto Process” Result Codes
Section17 Miscellaneous Commands
Appendix A - UsingFSC3000™ with Computer-Formatted Commands
Appendix B - CMI/Old Dominion(version 8.01) RFID Reader
Warranty
158
158
159
159
160
163
165
167
169
177
179
Page 10
Doc. No.:M00-051.00 Rev.: 10
Page 10 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 11
Doc. No.: M00-051.00 Rev.: 10
Page 11 of 181

Introduction

This ARTWare™(FSC) Command-Line guide is specifically written in support of the standard offering software referred to as “FSC3000 Multi-trucking Network Package, Standard Card Record Version.” There are other software versions of the FSC3000™family available for purchase and their command-line user interface generally operates based on the information provided within this manual (Except for Network related information). Contact your local Sales Representative or the OPW Tech Support group for information and commands specific to those versions of software.
For extended information related to the installation and support of the FSC3000™in regards to PCI DSS compliance please reference the “M030001 PA1 PA-DSS Implementation Guide.pdf.”
NOTE: The M030001 PA1 PA-DSS is provided as a printed version with every FSC shipped
with theFSC3000™Multi-trucking software. Contact your local distributor if this manual was not provided to you as the fuel site owner. You can also download the PA-DSS Implementation
Guide from the OPW web site www.opwglobal.com.
Page 12
Doc. No.:M00-051.00 Rev.: 10
Page 12 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 13

Section 1 Getting Connected

1.1 Communication Parameters

Baud Rate 2400, 9600, 19200, 38400 Data Bits 7 Parity Even Stop 1
Doc. No.: M00-051.00 Rev.: 10
Page 13 of 181
Figure 1-1 SW1- Baud Rate Settings
NOTE: Baud Rate will affect Terminal, Ethernet, Modem and pass-through port connections.

1.2 Connection Methods

Figure 1-2 FSC3000™Connections
Page 14
Doc. No.: M00-051.00 Rev.: 10
Page 14 of 181

1.3 Additional Connection Methods

TheFSC3000™allows for other, additional connection methods besides the standard internal modem normally available, including the Bluetooth®, Cell Modem, and WiFimodem. To utilize these additional connection methods, verify that the proper socket device type is shown on the FSC3000™under the SHOW FLAGS data (see above).
Bluetooth® (Socket device #2) and Cell (Socket device #4) connection methods are not currently available.
NOTE: Bluetooth® and Cell Modem are not allowed for use when a PCI compliant network is
enabled. These devices are automatically disabled by the FSC.

1.3.1 WiFi Modem

WiFi (Socket device #3)
To set up the WiFi Modem connection method, first connect to the FSC3000™using either a direct-connect serial cable or the Ethernet port.
The “Set WiFi” command is used to enter the settings needed for communication with the network access point (typically a wireless router). From the command line, type: Set WiFi.
If the modem is not found, it will be reported as “not found" and no settings can be entered. In this case, the modem is either not installed, or inoperable. Likewise, if a different modem is enabled, this will be reported. Otherwise, the following dialogue is used to enter settings. Based on your answers, some parts of the dialogue will be omitted.
P>set wifi
WiFi Modem Enabled
Enter Access Point Name (SSID): MyWirelessRouter(Router-Specific response)
Select WiFi Security:
1. WPA2 (Recommended)
2. WPA
3. WEP128 (Not PCI Compliant)
4. WEP64 (Not PCI Compliant)
5. None (Disables Security)
Enter Security Mode: 1 (Router-Specific response)
Enter Security Key: MyPassword(Router-Specific response)
Dynamic IP Address (DHCP On) (Y/N)? N (Router-Specific response)
Change Static IP Address: 0.0.0.0 (Y/N)? Y
New: 192.168.1.105 (Router-Specific response)
Change Gateway Address: 192.168.1.1 (Y/N)? Y
New: 192.168.1.1 (Router-Specific response)
Change Subnet Mask: “255.255.255.0” (Y/N)? N (Router-Specific response)
Page 15
Doc. No.: M00-051.00 Rev.: 10
Page 15 of 181
Periodically force modem reset if no call received (Y/N)? Y (normally “N”)
Reset modem if more than __ hours pass since last call (1-72)? 25
Reset Modem Now? y
The access point name and security settings are the same name that you would use connecting a laptop to your wireless network.
If your network automatically assigns IP addresses, answer yes for DHCP On. If answered “yes”, you will not be asked for the various IP addresses. If “no”, you’ll need to set the device’s IP address, the gateway address and the subnet mask.
The option is given to periodically reset, or reboot, the WiFi modem. In most cases this should be left off. However, if a site has intermittent connection issues, the modem can be set to automatically reset if it nothing connects to it for the set amount of hours. For instance, if the WiFi is only used to remotely gather totals every night at 2:00 AM, then a setting for 25 hours will cause a reboot if no connection was seen by 3:00 AM the following day.
Lastly, you’ll be asked if you wish to reset the modem now. Normally answer “y”. If you need to change a setting, answer “n” then use “SET WIFI” to correct the setting. If no restart is performed, the settings won’t take effect until the next restart.
NOTE: This only resets the modem, not the entire FSC3000
; however, if you are connected
via WiFi, this will drop your connection.
Once the modem resets (using a PC connected on the same network) login to the FSC3000™using a terminal emulation program with the IP address of the socket modem.
SHOW WiFi – If “Set WIFI” hasn’t been used to give the modem any settings, “SHOW WIFI” will report:
Wi-Fi not set yet, use SET WIFI
The “Show WiFi” command will first tell what socketdevice the flags are set for, if any. If it reports “No Modem Enabled” or “Cell Modem Enabled”, for example, then the wrong flag is set. If a modem is plugged in and set up, the command-line will resemble the following:
P>show wifi WiFi Modem Enabled Access Point Name (APNSERV): MyWirelessRouter (Router-specific response) WiFi Security: WPA2 (Recommended) Security Key: MyPassword (Router-specific response) Static IP Address: 192.168.1.200 Gateway Address: 192.168.1.1 Subnet Mask: “255.255.255.0” Port Number: 10001 Periodic WiFi resets: Off WiFi status: Configured Show Modem Responses (Y/N)? N
SHOW SYSTEM
As part of the “Show System” command, if the option flag for the WiFi modem has been set, just after version information, it should show “WiFi Modem:” followed by:
Not Found: Either there is no physical modem plugged into the socket,or it is not communicating
Page 16
Doc. No.: M00-051.00 Rev.: 10
Page 16 of 181
Not Configured: The modem is present, but user has not used ”Set WiFi” to give the modem connection
information
Configuring: The modem has been given setup information, but has not yet seen the access point
Configured: The modem has at some time connected to the access point. It may or may not be connected to
the access point at this instant, but the given settings are proven to be valid:
P>show sys
FSC3000: R/W Chipkey
Card Record Version #: 6.01a – Built: 7/01/11 – Serial #: Loader Ver: 1.01A June 20,2005 Loader2: 1.02A FPGA Ver: 3.0
Wifi Modem: Configured
IMPORTANT: The FSC3000's network port setting is set to 2101 during manufacturing. It
might have been changed during the FSC3000's network setup. Make sure the port settings match.
Page 17
Doc. No.: M00-051.00 Rev.: 10
Page 17 of 181

Section 2 Passwords

The FSC3000™(FSC) is designed to meet PA-DSS requirements for support of system access, password control and configuration. This section provides an overview of these controls.
Password support has been designed to provide the control necessary to manage the system and let the merchant/site owner meet their needs under PCI DSS compliance. A predefined “Admin” user and “Partial” access user are available under a new installation (cold started system). A “Remote” access password is always a requirement when entry through the internal modem or TCP/IP port is made.
IMPORTANT: Phoenix for Windows users: there is a character limit of 10 total characters for
the Partial Access mode.
and users: there is a character limit of 15 total characters for the Partial Access mode and
Remote Aceess paswords.
Under initial configuration of a cold started FSC, the system has been designed to allow site configuration by a Partial user using the default login (issue “hello” with password of “hello”). To be PCI compliant a card swipe is not allowed at a fuel island terminal until the default passwords have been changed and the system
has been started.
NOTE: Pump control testing can be done by issuing the “SET PUMP ON” command.
To start the system it is recommended that the installer have the site owner issue the “SET ADMIN” to modify the default passwords for Remote, Partial and Admin. If necessary the site owner can then create one of five (5) additional users for the installer to complete operational tests or provide an employee access to the
system. See below for more information on creating users.
IMPORTANT: It is required that after the Admin password is changed the site owner should
record it and store it in a safe and secure location. If the Admin password is lost it
cannot be retrieved from the system and a cold start will be required.
Below are some basic guidelines for password management. Please refer to your M030001_PA1 PA-DSS
Implementation Guide for additional information:
1. Change Partial, Remote and user passwords every 90 days (Admin password will be forced to change every 90-days).
2. When changing passwords, the new password should not be the same as any of the previous four (4).
3. Passwords for Admin, Partial, Remote and users should always be unique.
IMPORTANT: If the User or Admin passwords are entered incorrectly six (6) consecutive
times, the User or Admin will be suspended for 30 minutes before another login attempt is allowed. If the Admin is not locked out, the Admin can reset the User password with the “SET ADMIN” command.
Page 18
Doc. No.: M00-051.00 Rev.: 10
Page 18 of 181
Although the system access and password control discussed above is always in place, additional controls are imposed when the follow networks are enabled. As the site owner, you are required to maintain PCI DSS compliance when these networks are in use at your fuel site(s).
Bankcard processing hosts:
Buypass (Firstdata)
NBS Bank
Paymentech (Chase)
MasterCard Fleet processing hosts:
Comdata (Terminal Fuel)
ComdataPOS (Retail Host)
T-Chek or TCH (EFSLLC)
CFN
For further information on installing your system, refer to M030001 (U.S.) or M030007 (U.S and Canada EMV) “Payment Application Data Security Standards (PA-DSS) Implementation Guide for Maintaining PCI Compliance on theFSC3000™Fuel Site Controller.”
IMPORTANT: Reading the PA DSS guide is required for System Installers and Controlling
Merchants for PCI DSS compliance.

2.1 Security Levels

2.1.1 Remote Access (Modem or Ethernet)

The Remote Access password is required when accessing the FSC3000™system using the internal dial­in modem or Ethernet network port. The default, case-sensitive password is “hello”. This password will automatically be requested when first connected to the FSC3000™. Once the Remote Access password is entered, the system prompt “r>” or "l>" will be displayed (where r> = modem and l> = Ethernet).

2.1.2 Partial Access (or “Main Password”)

The Partial Access password is accessible from the system prompt “r>” or "l>". When “hello” is entered, the system prompt “ENTER MAIN PASSWORD:” will be displayed. The default, case-sensitive Partial Access password is “hello”. This password functions in two (2) ways. Once the Partial Access password is entered, the Partial Access prompt will be displayed.
Direct connected – “P>” Modem connected - “R>” Ethernet connected – “L>”
1. Prior to “SYSTEM START” command:
This password will allow full access to every command for initial configuration. Because the system is not yet started, cards will not be processed.
2. After “SYSTEM START” command:
Page 19
Doc. No.: M00-051.00 Rev.: 10
Page 19 of 181
The Partial Access password will be limited to these select commands:
Show - System, Version, Flags, PCT x, FIT x, VIT x, Transaction CF Install Pump x (clear pump sentry) Set Fueltype (change product prices PCF Automated management commands - Card backup/restore/update Passthru

2.1.3 User Access

The system supports up to five (5) defined users that have access to all commands except “SET ADMIN, SET NETWORK, or SET FLEET.” Individual users can be set up to see bank card ISO numbers (first six (6) digits) in the transactions when performing “SHOW TRANSACTION” commands. Users can also be limited to the number of days of system access.To access the system using a User password, type “LOGIN” <user name>. A prompt for the User’s password will be displayed. Once the User password is entered, the user prompt “(User Name)>” will be displayed.

2.1.4 Admin Access

The Admin is the predefined user who has access to every command. It is recommended that the Admin account only be used if the “SET ADMIN, SET NETWORK, or SET FLEET” commands are needed. The
Admin account is limited in access to the system through only a Direct or Dial-in connection. A User account is needed to access the FSC3000™system if a TCP/IP connection is in use.
The Admin password should be stored in a safe location. Once the Admin password is entered, the prompt “Admin>” will be displayed.

2.2 Set Admin (Admin Login Required)

The Set Admin command allows for the management of the supported five (5) additional users of the system, and clears the system log. This command will not be available when connected using Ethernet. Once theFSC3000™system is started, only the Admin will be able to access this command.
Type: Set Admin <ENTER>
Administrator Menu
1. Create User (free:x)
2. Delete User
3. Show User(s)
4. Change Password(s)
5. Clear Event Log
Select Administrator option or press [ENTER] to exit:

2.2.1 Create User

The Create User option allows up to five (5) other users of the system. Each user can be set up to either see or not see bankcard ISOs and can be configured to define a time limit (in days) to system access.
Enter a new (case sensitive) USER name: Tech (maximum 10 characters) Passwords MUST be a minimum length of eight (8) characters (max 15), contain at least one numeric digit, one lower-case character and one upper-case character.Special characters are optional.
Enter Password for Tech: ******* Re-enter to confirm password: *******
When viewing transactions can this user see a bankcard's ISO (Y/N)? Y
Is this a time limited User (Y/N)? y
Page 20
Doc. No.: M00-051.00 Rev.: 10
Enter number of days allowed (15 max): 15
USER "Tech" has been successfully created!

2.2.2 Delete User

The Delete User option allows for the deletion of users from the system.

2.2.3 Show User(s)

The Show Users option displays all users defined in the system. If the user was defined as a limited-time user, the user’s remaining time will also be displayed.
Select “Administrator” option or press [ENTER] to exit: 3
User1: Tech - (limited time access: 1 day)

2.2.4 Change Passwords

The Change Passwords command changes the passwords for Remote Login, Partial Access,
Administrator and all defined Users.
Page 20 of 181

2.2.5 Clear Event Log

The Clear Event Log option clears the system log. Refer to Show Log (Saving Log) and the “M030001 PA1-PA-DSS Implementation Guide” before clearing the system log.

2.3 System Start

The System Start command is a one-time command that activates the FSC3000™system, allowing transactions to be processed. Before this command can be performed, the “SET ADMIN” command (option 4) must be used to change the factory default passwords.
Type: System Start <ENTER>

2.4 Password Recovery

Due to the requirements of PA-DSS compliance, password recovery is no longer available. It is up to the system owner to secure the passwords. If the Administrator password is lost, the FSC3000™system will require a cold start and must be reprogrammed to regain Admin access.
Page 21

2.5 Cold Start Procedure

Doc. No.: M00-051.00 Rev.: 10
Page 21 of 181
Figure 2-1 FSC3000™ColdStart Procedure
To cold start the FSC3000™:
1. Power down the unit by unplugging the power cord on the rear panel.
2. Plug the power cord back in and at the same time, push and hold the two (2) front panel
buttons.
3. A “Beep” will sound.
4. Release the front panel buttons
5. The front panel display will show that the FSC has been cold started.
Make sure the system is operational.
IMPORTANT: A cold start will reset the FSC3000 to factory default settings. All card records
and transaction data will be erased.
On the initial FSC3000™setup it is recommended that the distributor wait to issue the “Set Admin” & “System Start” commands until the system has been fully configured and tested. Pump control testing can be done by issuing the “SET PUMP ON” command. FIT functionality can be tested by swiping a card to receive the “System Stopped…” message.
NOTE: The “System Start” command must be issued before network testing can be
performed.
Page 22
Doc. No.:M00-051.00 Rev.: 10
Page 22 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 23
Doc. No.: M00-051.00 Rev.: 10
Page 23 of 181

Section 3 Show Flags

The FSC3000™software has options that can be purchased. All software options should be verified to be correct when the FSC3000™is received. To do this, issue the following command:
Show Flags <ENTER>
FSC3000 PA-DSS Certified Version: 2.0 App Ver: 1.14c Serial #: 123456 DPC Options: 10.04A Gilbarco/Wayne
11.01C Tokheim FPGA Ver: 2.0 Loader Ver: 1.02A Jun 30, 2005 Loader2 Ver: 1.02B
MAX CARDS: 65000 (Maximum number of cards FSC3000 purchased) SERIAL #: 12345 (Number needed when adding options to system)
MAX TRANS: 2000
W&M 3 MIN PUMP TIMER: disabled
W&M PPU FLAG: disabled
Not Used, Do Not Set: disabled (Disabled) Not Used, Do Not Set: disabled (Disabled)
DPC FLAG:
AUTOGAS FLAG: disabled (Allows use of Autogas cards)
DUAL HOST AVAILABLE: disabled
PAC-PRIDE CARD RECORD: disabled (Pacific Pride Fueling Network) RECORD BYPASS TRANS
(SF024): COMDATA FLAG: disabled (Network) T-CHEK FLAG: disabled (Network) EFS FLAG: disabled (Network) TCH FLAG: disabled (Network) FLEET1 FLAG: disabled (Network) CFNÂ FLAG: disabled (Network) NBS/BANK FLAG (SF015): disabled (PCI Network) NBS/FMGC FLAG (SF016): disabled (Network) QUARLES FLAG: disabled (Network) PAYMENTECH FLAG (SF025): GENERIC NETWORK FLAG: disabled (Network) KARDALL IPH FLAG: disabled (Network) INTEVACON NETWORK FLAG: disabled (Network) QUICK FUEL NETWORK FLAG: disabled (Network) FEDERATED NETWORK FLAG: disabled (Network) COMPANY CARD NETWORK FLAG: disabled (Network) ATIO-NET NETWORK FLAG: disabled (Network) IRVING FLAG: disabled (Network)
ß ENABLED
disabled
ß ENABLED
(Maximum number of transactions FSC3000 purchased)
(Weights & Measures – max three-minute total fueling times)
(Weights & Measures – only allows 1, 10, 100, 1000 pulse rates)
(Allows direct control of electronic dispensers)
(Allows 2 network connection devices – modem, etc.)
(Record transactions when pump in Bypass – PCMs only)
(PCI Network)
Page 24
Doc. No.: M00-051.00 Rev.: 10
SHELL FLAG: disabled (Network)
USB KEY FLAG: disabled
SOCKET DEVICE: 1
PRICE SIGN SUPPORTED:
LOYALTY CARD FLAG
BULK PLANT FLAG
TIERED DISCOUNTS: (Tiered pricing against Gasboy track 2 data)
TIERED ACCOUNTS:
ß ENABLED
(Allows card updates to be performed via USB key)
(Define device in socket - Blank/1 = modem, 2 = Bluetooth, 3 = WiFi, 4 = Cell modem)
(Allows price sign functionality) (Allows misc. collection of data under
Paymentech and NBS/CHASE Bank) (Support for net/gross pulser values, FCL
only)
(Provides tiered pricing prompt for network cards and tiered pricing for PCF based cards)
EXECUTING OUT OF FLASH FLASH ADDRESS BLOCKS:
0:100000-17FFFF (7E4B) Main App 8:500000-57FFFF (7E4B) 1:180000-1FFFFF (8512 [035D] 9:580000-5FFFFF (8512) 2:200000-27FFFF (5E23) Prod Ship 10:600000-67FFFF (57E8) PCI Cert 3:280000-2FFFFF (BLNK) 11:680000-6FFFFF (BLNK) 4:300000-37FFFF (1B30) 12:700000-77FFFF (4D02) Log Buffer 5:380000-3FFFFF (5A64) 13:780000-7FFFFF (BLNK) Sys Params 6:400000-47FFFF (1B30) 14:800000-87FFFF (3140) Boot Ldr 7:480000-4FFFFF (A168) USB Boot 15:880000-8FFFFF (FA90) FactoryUse
16:900000-97FFFF (5ECA) RAM
Page 24 of 181
Page 25
Doc. No.: M00-051.00 Rev.: 10

Section 4 Time Management

4.1 Set Time

To Set Time type: Set Time <ENTER>
Enter time (XX:XX AM/PM):(May enter in 24 hour or AM/PM format)

4.2 Set Date

To Set Date type: Set Date <ENTER>
Enter Date (MMM DD, YYYY): (Month is entered as APR for April, JUN for June, etc.)

4.3 Set Time Change

Page 25 of 181
NOTE: Time changes are not automatic in the FSC3000
using the steps below.
To Set Time Change type: Set Time Change <ENTER>
Enter date when time is moved BACK 1 hour: Inactive Enter date when time is moved FORWARD 1 hour: Inactive BACK 1 hour: INACTIVE FORWARD 1 hour: INACTIVE

4.4 Set System Time

To Set System Time type: Set System Time <ENTER>
Set system ON time (Y/N)? N Set system OFF time (Y/N)? N Set 'RECEIPTS ONLY' time (Y/N)? N Set time adjust (Y/N)? N (Enter N for this)
NOTE: This feature allows an offset in seconds (a plus or minus value) applied at midnight to
account for system clock drift.

4.5 Set Light

To Set Light Time type: Set Light <ENTER>
. Time changes must be set up
Enter light ON time: Inactive Enter light OFF time: Inactive Light ON time: Inactive Light OFF time: Inactive
NOTE: This setting applies to the Lighted keypad and card reader on supported terminals
Page 26
Doc. No.:M00-051.00 Rev.: 10
Page 26 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 27
# Name Units Price PTECH COM UNI FMGC QsFN FLT1 CFN
1 UNLEADED GALLONS 1.000 001 0 051 002 12 40 04
2 PREMIUM GALLONS 1.000 002 0 053 004 09 41 05
3 SUPER GALLONS 1.000 003 0 055 003 10 42 06
4 SPEC BULK GALLONS 1.000 004 0 017 N/A N/A N/A N/A
5 #1 DIESEL GALLONS 1.000 005 1 010 030 03 31 13
6 #2 DIESEL GALLONS 1.000 006 2 001 005 06 12 01
7 REEFER GALLONS 1.000 007 0 081 036 N/A 14 N/A
8 WINTER DSL GALLONS 1.000 008 0 056 003 N/A 30 N/A
9 KEROSENE GALLONS 1.000 009 0 048 N/A N/A 32 N/A
10 UNLEAD BLK GALLONS 1.000 010 0 052 N/A N/A N/A N/A
11 LUBE OIL1 GALLONS 1.000 011 3 071 045 11 N/A 08
12 LUBE OIL2 GALLONS 1.000 012 3 072 822 N/A N/A 09
13 TRANS OIL GALLONS 1.000 013 3 075 808 N/A N/A N/A
14 COOLANT GALLONS 1.000 014 0 076 605 14 N/A N/A
15 PROPANE GALLONS 1.000 015 0 080 039 N/A 39 17
Doc. No.: M00-051.00 Rev.: 10

Section 5 Fuel Types & Tank Setup

5.1 Fuel Types

5.1.1 Set Fueling Units

One of three (3) units of measure can be associated with the fuel types. These are simply labels; no conversion is done.
To set Fueling Unit type: Set Fueling Unit <ENTER>
Enter fueling UNIT 1: GALLONS Enter fueling UNIT 2: LITERS Enter fueling UNIT 3: QUARTS
NOTE: When defining fueltype codes refer to the specific networks in "Host Specific Setup
Options " on page97.
Page 27 of 181

5.1.2 Set Fueltype

Up to 32 products in the system can be defined. Each product’s name, unit of measure label, Price Sign Grade (if enabled), price per unit and network product code can be set. If the Price Sign feature is enabled, there is an additional field used to assign the Price Sign Grade.
To set fuel type, type: Set Fueltype <ENTER>.
Page 28
16 E-85 GALLONS 1.000 016 0 090 000 N/A 45 29
17 ULS BIO 2% GALLONS 1.000 017 0 202 N/A N/A 55 N/A
18 ULS BIO 5% GALLONS 1.000 018 0 205 N/A N/A 56 N/A
19 ULS BIO 10% GALLONS 1.000 019 0 210 N/A N/A 57 N/A
20 ULS BIO 11% GALLONS 1.000 020 0 211 N/A N/A 58 N/A
21 ULS BIO 15% GALLONS 1.000 021 0 215 N/A N/A 59 N/A
22 ULS BIO 20% GALLONS 1.000 022 0 220 N/A N/A 60 N/A
23 BIO OFF RD GALLONS 1.000 023 0 230 N/A N/A 66 38
24 B2 BIO 2% GALLONS 1.000 024 0 260 N/A N/A 68 66
25 B2 BIO 5% GALLONS 1.000 025 0 261 N/A N/A 36 67
26 B2 BIO 10% GALLONS 1.000 026 0 262 N/A N/A 37 68
27 B2 BIO 11% GALLONS 1.000 027 0 263 N/A N/A 38 N/A
28 B2 BIO 20% GALLONS 1.000 028 0 264 N/A N/A 60 69
29 AVIATION GALLONS 1.000 029 0 084 N/A N/A 51 20
30 CNG GALLONS 1.000 030 0 016 N/A N/A 47 16
31 EXTRA GALLONS 1.000 031 0 000 N/A N/A N/A N/A
32 EXTRA GALLONS 1.000 032 0 000 N/A N/A N/A N/A
1 UNLEADED GALLONS 2.000 001 0 051 002 12 40 04
Doc. No.: M00-051.00 Rev.: 10
Page 28 of 181
*<name> = Product DENIED when locally authorized. TAX Included in price per unit: YES ENTER (fuel table row # (1...32) or [RETURN] to exit):
The product table defaults to the products defined above. Fuel type names can be changed. If using networks, the network product code must be mapped correctly to the product that is being set up. To set up fuel type, enter the row that needs to be edited.
ENTER (fuel table row # (1...32) or [RETURN] to exit): 1
*<name> = Product DENIED when locally authorized.
TAX Included in price per unit........ YES
Enter NAME: UNLEADED Enter UNIT of measure (1=GALLONS 2=LITERS 3=QUARTS): 1 Enter PRICE: 2.000 (decimal must be entered) Enter PAYMENTECH fuel type code: 001 (only networks that are enabled will prompt for code) Enter UNIVERSAL fuel type code: 051 (except Universal which will prompt always) Enter FUELMAN/GASCARD fuel type code: 002 Enter CFN fuel type code: 04 Deny this product when LOCAL AUTHORIZATION is active and supported by the network (Y/N)? Y Map (or clear) this product to a Price Sign Product Grade (Y/N)? Y (Only available if PRICE SIGN SUPPORTED is enabled (Optional)) Enter price sign grade (1-8) to map (zero to clear): Enter (fuel table row # (1…32) or [RETURN] to exit):
Page 29
Paymentech Comdata Universal
Fuelman Gascard
Quarels Fueling Network
FleetOne CFN
PTECH COM UNI FMGC QsFN FLT1 CFN
Atio-Net X
BUYPASS X
Card Company X
CFN X
Comdata X
EFS X
Federated Co-op X
FleetOne X
Generic X
Intevacon X
KardAll X
NBS - BANK X
NBS - FMGC X
Paymentech X
T-Chek X
TCH X
TCH - Irving Oil X
TCH - Shell Canada
X
QuikFuel X
Doc. No.: M00-051.00 Rev.: 10
Below is a list of networks, showing which fuel type network product code column that the specific network will use when processing network cards.
Page 29 of 181

5.1.3 Set Tiered Discounts

TheFSC3000™allows you (when the proper flags are enabled) to assign 10 levels of discounted pricing for each product available in the system. These “tiered” levels can be configured by the tier code or by specific products.The Tiered Discounts section guides you through the usage of the “Set Tier” command.
NOTE: In order to use tiered pricing, you must have either the Tiered Discounts flag, or the
Tiered Accounts flag (see Section 5.1.5), or both tiered flags enabled on the FSC3000™.
To set tier discounts, type: set tier <ENTER>.
Page 30
Doc. No.: M00-051.00 Rev.: 10
TIERED DISCOUNTS TABLE
(displayed in tenths of a penny)
Tier Code 0 1 2 3 4 5 6 7 8 9
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ­PROD 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 10 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 11 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 12 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 13 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 14 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 15 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 16 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 17 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 18 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 19 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 20 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 21 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 22 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 23 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 24 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 25 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 26 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 27 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 28 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 29 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 30 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 31 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 32 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
1 - ENTER DISCOUNTS BY TIER CODE 2 - ENTER DISCOUNTS BY PRODUCT CODE X - EXIT
Page 30 of 181
Page 31
Doc. No.: M00-051.00 Rev.: 10
Page 31 of 181
The tiered discounts table defaults to the values above. To set discounts according to product, select option 2, then select the product for which you wish to set discounts.
SELECT OPTION: 2 ENTER PRODUCT CODE: 2
TIERED DISCOUNTS TABLE
(displayed in tenths of a penny)
Tier Code 0 1 2 3 4 5 6 7 8 9
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ­PROD 2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
The Tiered Discounts Table will appear, as above, displayed in tenths of a penny. To change the discounts, enter each desired discount. No entry will result in “no change”. Press “Enter” after each entry to proceed to the next line.
Enter Tier 0 Discount: 3.9 Enter Tier 1 Discount: NO CHANGE Enter Tier 2 Discount: NO CHANGE Enter Tier 3 Discount: NO CHANGE Enter Tier 4 Discount: 2.2 Enter Tier 5 Discount: NO CHANGE Enter Tier 6 Discount: NO CHANGE Enter Tier 7 Discount: NO CHANGE Enter Tier 8 Discount: NO CHANGE Enter Tier 9 Discount: NO CHANGE
TIERED DISCOUNTS TABLE
(displayed in tenths of a penny)
Tier Code 0 1 2 3 4 5 6 7 8 9
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ­PROD 2 3.9 0.0 0.0 0.0 2.2 0.0 0.0 0.0 0.0 0.0
ENTER PRODUCT CODE:
The Tiered Discounts Table will now display the changes you’ve made.
Page 32
Doc. No.: M00-051.00 Rev.: 10
To set discounts according to the tier encoded on the user’s card, begin the process by again typing: P>set tier.
TIERED DISCOUNTS TABLE
(displayed in tenths of a penny)
Tier Code 0 1 2 3 4 5 6 7 8 9
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ­PROD 1 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 PROD 2 3.9 0.0 0.0 0.0 2.2 0.0 0.0 0.0 0.0 0.0 PROD 3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 10 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 11 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 12 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 13 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 14 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 15 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 16 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 17 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 18 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 19 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 20 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 21 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 22 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 23 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 24 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 25 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 26 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 27 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 28 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 29 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 30 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 31 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PROD 32 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Page 32 of 181
1 - ENTER DISCOUNTS BY TIER CODE 2 - ENTER DISCOUNTS BY PRODUCT CODE X - EXIT
Page 33
Doc. No.: M00-051.00 Rev.: 10
Page 33 of 181
The Tiered Discounts Table defaults to the above values. To enter discounts according to the tier embedded on the card, select option 1, then enter the Tier Code that corresponds to the tier you wish to set.
SELECT OPTION: 1
ENTER TIER CODE: 0 Enter Tier 0 Discount For
Product 1 (0.0): 3.5 Product 2 (3.9): NO CHANGE Product 3 (0.0): NO CHANGE Product 4 (0.0): NO CHANGE Product 5 (0.0): NO CHANGE Product 6 (0.0): NO CHANGE Product 7 (0.0): NO CHANGE Product 8 (0.0): NO CHANGE Product 9 (0.0): NO CHANGE Product 10 (0.0): NO CHANGE Product 11 (0.0): NO CHANGE Product 12 (0.0): NO CHANGE Product 13 (0.0): NO CHANGE Product 14 (0.0): NO CHANGE Product 15 (0.0): NO CHANGE Product 16 (0.0): NO CHANGE Product 17 (0.0): NO CHANGE Product 18 (0.0): NO CHANGE Product 19 (0.0): NO CHANGE Product 20 (0.0): NO CHANGE Product 21 (0.0): NO CHANGE Product 22 (0.0): NO CHANGE Product 23 (0.0): NO CHANGE Product 24 (0.0): NO CHANGE Product 25 (0.0): NO CHANGE Product 26 (0.0): NO CHANGE Product 27 (0.0): NO CHANGE Product 28 (0.0): NO CHANGE Product 29 (0.0): NO CHANGE Product 30 (0.0): NO CHANGE Product 31 (0.0): NO CHANGE Product 32 (0.0): NO CHANGE
Entering a number for each product will set the discount at that number. Leaving the line blank and pressing “Enter” will result in “no change”.
Page 34
Doc. No.: M00-051.00 Rev.: 10
The “Tiered Discounts” flag feature of theFSC3000™was designed to support the tiered price code embedded in the Track2 on your existing Gasboy cards. However, because of the many different Gasboy Track2 formats available, the FSC3000™has no knowledge of where to find the embedded tiered pricing code. Therefore, you must configure the FSC to identify the position within the card’s Track2 data that represents the Tiered Discount indicator. The configuration is done using the “SET CARDS” command.
P> P>set cards
1 - Specify Card/Trans Buffer Size 2 - Define Card/Account Record 3 - Clear Card Record Totals 4 - Reconcile Card Record Allocation 5 - Clear All Account Record Totals 6 - Reconcile Account Record Allocation 7 - Month End Totals 8 - Additional Options 9 - Card Buffer Placement (Currently in Simm 1) X - Exit
Enter Choice: 8
Card invalid after 3 BAD PINs (Y/N)?
Page 34 of 181
Process ALL Voyager cards as PCF based (Y/N)? N
Set Track2 Position for Gasboy Tiered Discount Indicator (Y/N)? y
Enter Track2 'Price Level' Position: 24
--Track2 Position for Gasboy Tiered Discount Indicator: 24
1 - Specify Card/Trans Buffer Size 2 - Define Card/Account Record 3 - Clear Card Record Totals 4 - Reconcile Card Record Allocation 5 - Clear All Account Record Totals 6 - Reconcile Account Record Allocation 7 - Month End Totals 8 - Additional Options 9 - Card Buffer Placement (Currently in Simm 1) X - Exit
Enter Choice:

5.1.4 Tiered Accounts

The Tiered Accounts feature of the FSC3000™is designed to provide “Tiered” pricing against cards that are always processed to a host enabled within the FSC3000™. When this feature is enabled, theFSC3000 forces a specific prompt to always be presented before any other prompt that might normally occur for the card in use.
The prompt used for Tiered Accounts is always the ‘D’ prompt found using the “SET PROMPTS” command. The default message for this prompt is; “ENTER TIERED ACCOUNT # (zero to skip):” You can modify this prompt to meet your needs, but consider leaving the “(zero to skip)” message. The “(zero to skip)” message informs users who have not been assigned a tiered account on how to bypass the prompt.
See Tiered Discounts above for configuration of Tiered Pricing.
Configuring Tiered Accounts: To allow you to use the OPW Phoenix™ applications for managing Tiered Accounts the support has been designed to work within the boundaries of the existing Proprietary Card File
Page 35
Doc. No.: M00-051.00 Rev.: 10
setup. To enable Tiered Accounts you must first define the Card File on the FSC to use Odometer Reasonability; do this by issuing the “SET CARDS” command.
P>set cards
1 - Specify Card/Trans Buffer Size 2 - Define Card/Account Record 3 - Clear Card Record Totals 4 - Reconcile Card Record Allocation 5 - Clear All Account Record Totals 6 - Reconcile Account Record Allocation 7 - Month End Totals 8 - Additional Options 9 - Card Buffer Placement (Currently in Simm 1) X - Exit
Enter Choice: 2
Card/Account Records: 0 Out of possible 100 # of transactions: 100
Specify Card/Account record (Y/N)? y
Page 35 of 181
--Card/Account file will be DESTROYED !!! Sure (Y/N)? y
Account #'s (Y/N)? y ← Required for Tiered Accounts Expiration Date (Y/N)? N Monthly Allocation (Y/N)? N Daily Allocation (Y/N)? N PIN # (Y/N)? N Save Odometer Entries (Y/N)? y ← Required for Tiered Accounts Odometer Reasonability (Y/N)? y ← Required for Tiered Accounts Product Restriction (Y/N)? N Quantity Restriction (Y/N)? N Driver / Vehicle / Account Name (Y/N)? y Verify 1 (Y/N)? N Verify 2 (Y/N)? N Verify 3 (Y/N)? N Prompt-Seq. (Y/N)? N
Maximum Cards/Accounts: 100
1 - Specify Card/Trans Buffer Size 2 - Define Card/Account Record 3 - Clear Card Record Totals 4 - Reconcile Card Record Allocation 5 - Clear All Account Record Totals 6 - Reconcile Account Record Allocation 7 - Month End Totals 8 - Additional Options 9 - Card Buffer Placement (Currently in Simm 1) X - Exit
Enter Choice:
P>
Now you must create cards in the proprietary card file to be used as account numbers that will be keyed in during a network transaction. This is done by issuing the “INSERT CARD” command as follows;
Page 36
Doc. No.: M00-051.00 Rev.: 10
Page 36 of 181
P>insert card Enter Card #: 1254031 Card type (S)ingle, (D)river, (V)ehicle: s Valid (Y/N)? y Account # (0-9999): 9999 ß Any cards created as a Tiered Account record must be assigned to
account number “9999”
Enable MISC entry (Y/N)? N Enter current ODOM: Disabled ß Do not enter an Odometer Value for the card just press enter
When using Tiered Accounts, the Odometer Reasonability field references the Tiered Discounts table (0-9) with values from 1-10. A value of zero indicates NO Discount or Reasonability. Reason codes from 11-15 can still be used for Reasonability without applying a discounted price to the card.
Odom Reasonability/Tiered Account CODE: 3
Driver or Vehicle Name: Tier3
--Any more cards (Y/N)? N SORT DONE P>
Now, when a network-based card is swiped, the ‘D’ prompt message will be displayed. If the account number of “1254031” is keyed in, the Tiered Discount price drop associated to the selected products level “3” value will be applied.
ß Account will use Tier
Discount ‘3’
Page 37
Doc. No.: M00-051.00 Rev.: 10

5.2 Tanks

5.2.1 Set Tank # (# = 1 to 8)

The FSC3000™controller supports declining inventory. This command allows for the assignment of fuel types to the tanks. When fuel is pumped, it is subtracted from the assigned tank. This setup is not required.
NOTE: This feature only supports straight products – no blending.
To set Tank, type: Set Tank #<ENTER>
Fuel Type CODE (1-32): Enter the fuel type number to assign the tank product Enter QUANTITY: Enter the current inventory level of the tank Tank LOW QUANTITY: Enter the level at which the FSC would display the tank is low
Tank ##: (Product Name) Quantity: 0.0 LOW Level: 0.0
The Show Tank command can be used to verify setup.
Page 37 of 181
Tank #1 UNLEADED Quantity: 0.0 LOW Level: 0.0 Tank #2 UNLEADED Quantity: 0.0 LOW Level: 0.0 Tank #3 UNLEADED Quantity: 0.0 LOW Level: 0.0 Tank #4 UNLEADED Quantity: 0.0 LOW Level: 0.0 Tank #5 UNLEADED Quantity: 0.0 LOW Level: 0.0 Tank #6 UNLEADED Quantity: 0.0 LOW Level: 0.0 Tank #7 UNLEADED Quantity: 0.0 LOW Level: 0.0 Tank #8 UNLEADED Quantity: 0.0 LOW Level: 0.0
Page 38
Doc. No.:M00-051.00 Rev.: 10
Page 38 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 39
Doc. No.: M00-051.00 Rev.: 10
Page 39 of 181

Section 6 Pump Setup

6.1 Mechanical Pumps

6.1.1 Configure PCT # (# = 1 to 8)

Originally, the FSC3000™was designed to control mechanical pumps using a board called a PCT (Pump Control Terminal). The ability to control mechanical pumps with an integrated PCT in the K800™Hybrid terminal and a board called a PCM (Pump Control Module) has since been added. The configuration of the different mechanical pump interfaces, however, is still the same. The first step is to indicate the kind of mechanical pump interface that the system will interface with. The system can support up to four (4) PCTs. Even though the interfaces are not all the same, they are still configured as PCTs.
If using PCT (Mechanical), up to eight (8) positions per PCT (4 PCTs allow for 32 pumps) are supported.
If using PCM/K800 PCT– up to four (4) positions per controller (8 PCMs allow for 32 pumps) are supported.
Page 40
Doc. No.: M00-051.00 Rev.: 10
If using K800™ PCT or PCM (Mechanical), up to four (4) positions maximum are supported.
Type: Configure PCT # (K800 PCT and PCM addressable from 1 to 8)
Is this a K800 PCT or PCM (Y/N)? Y
Page 40 of 181

6.1.2 Configure PCT # POS # (PCT 1 to 8 and POS 1 to 8)

The Configure PCT # POS # command configures each fueling point that is connected to the specific PCT. Each fueling point is to be wired to a specific position on the pump interface.
Type: Configure PCT # POS # <ENTER>
PCT 1 Position 1 (Indicates what position is being configured) Enter Pump #: 1 (Enter the pump # that is connected to this PCT POSITION) Enter Pulses Per GALLONS: 100 (Enter the pulse rate for the pump) MAX Fuel to be dispensed per transaction: 10 (Largest tank to be filled for this pump) Pump Sentry Options (Y/N)? Y (Protects against pulser\wire failure) Pump Sentry: ENABLED Maximum time allowed for fueling (Minutes): 5 Maximum time allowed to retrieve pump handle (Seconds): 60 Maximum time allowed to detect first fueling pulse (Secs): 60 Maximum time allowed between fueling pulses (Secs): 30 Enter Fueltype Code #: 1 (Enter the fuel type code for the product that will be dispensed) Enter Tank #: 1 (Enter Tank number – not required for proper operation) Clear Pump Totals (Y/N)? N Enter Totalizer Value: 0.0 (Should set to match fueling point mechanical totalizer)
Repeat process to configure each position that is wired to a fueling point.

6.1.3 Install PCT # POS # (PCT 1 to 8 and POS 1 to 8)

The Install PCT # POS # command tells the system that a PCT position will be used.
Repeat process to install each configured position.

6.1.4 Install PCT # (# = 1 to 8)

The Install PCT # command tells the system that the PCT is there and it should communicate with it.
Page 41
Doc. No.: M00-051.00 Rev.: 10
Page 41 of 181

6.2 Electronic Pumps Controlled by UPC

The FSC3000™controller has been enhanced to support product restriction. The FSC3000™controller requires the UPC software to meet or exceed the following versions:
Gilbarco – 6.21A or greater
Tokheim – 1.03B or greater
Wayne – 7.05C or greater
Ruby CI / Commander – Base 40 or greater

6.2.1 Configure PCT # (# = 1 to 4)

The Configure PCT # allows for communication to a pump console or controller to control electronic pumps through a device called a UPC (Universal Pump Controller). The UPC can emulate up to four (4) PCTs at once. The interface uses a UPC to control the pumps. All system configurations will be referred to as a PCT.
If using a UPC as the PCT (Electronic):
Type: Configure PCT #
Is this a K800 PCT or PCM (Y/N)? N Is this a UPC/DPC (Y/N)? Y

6.2.2 Configure PCT # POS #

PCT 1 Position 1 (Indicates the position being configured) Enter Pump #: 1 (Enter the pump # that is connected to this PCT POS) Enter Pulses Per GALLONS: 100 (set to 1000) MAX Fuel to be dispensed per transaction: 10 (Largest tank to be filled for this pump) Pump Sentry Options (Y/N)? Y (Protects against pulser/wire failure) Pump Sentry: ENABLED Maximum time allowed for fueling (Minutes): 5 Maximum time allowed to retrieve pump handle (Seconds): 60 Maximum time allowed to detect first fueling pulse (Secs): 60 Maximum time allowed between fueling pulses (Secs): 30 Set Up Hose 1 (Y/N)? y
Enter Fueltype Code #: 1 (Enter the fuel type code) Enter Tank #: 1 (Enter Tank number – not required for proper operation) Clear Pump Totals (Y/N)? N Enter Totalizer Value: 0.0 (Should set to match fueling point totalizer) Set Up Hose 2 (Y/N)? N (Only required if pump has more than 1 grade!) Set Up Hose 3 (Y/N)? N (Must match how the console reports hoses to the UPC) Set Up Hose 4 (Y/N)? N Set Up Hose 5 (Y/N)? N Set Up Hose 6 (Y/N)? N Set Up Hose 7 (Y/N)? N Set Up Hose 8 (Y/N)? N
Repeat the process to configure each position that is wired to a fueling point.

6.2.3 Install PCT # POS # (PCT 1 to 4 and POS 1 to 8)

The Install PCT # POS # command tells the system that a PCT position will be used.
Repeat the process to install each configured position.
Page 42
Doc. No.: M00-051.00 Rev.: 10

6.2.4 Install PCT # (# = 1 to 4)

The Install PCT # command tells the system that the PCT is there and to communicate with it.
EXAMPLE:
Page 42 of 181
Page 43
Doc. No.: M00-051.00 Rev.: 10

6.3 Electronic Pumps Controlled by DPC (Wayne)

6.3.1 Install Program

The first step of installation is to define the brand of electronic pumps that will be used and the communication parameters of each pump. The FSC3000™is designed to support up to eight (8) PCT devices, but DPC is limited to the first four (4) PCTs.
Type: Install program
Install program (or Configure program if already installed)
SELECT DPC PROGRAM TO INSTALL
1: GILBARCO / WAYNE 2: GASBOY
ENTER SELECTION: (1) INSTALLING, PLEASE WAIT... SUCCESSFUL! (Successful should appear after installed) **** DIRECT PUMP SETTINGS –Ver. 10.01D ****
Select pump types:
1-Gilbarco, 2-Wayne: (1)2
Set pump communication port:
Baud: 1-1200, 2-2400, 3-4800, 4-5760, 5-9600 -> (?)5
Character size: 1-7 bits, 2-8 bits -> (1)2
Parity: 1-Odd, 2-Even, 3-None -> (2)1 **** DIRECT PUMP VERSION: 10.01D **** Pumps: Wayne Baud rate: 9600, Data bits: 8, Parity: Odd, Stop bits: 1
Page 43 of 181

6.3.2 Configure PCT # (# = 1 to 4)

The Configure PCT # command defines the PCT that is used for DPC.
Configure PCT # (# = 1 to 4) Is this a K800 PCT or a PCM (Y/N)? N Is this a UPC/DPC (Y/N)? Y

6.3.3 Configure PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)

Configure PCT # POS #
PCT 1 Position 1 (Indicates the position being configured) Enter Pump #: 1 (Enter the pump # that is connected to this PCT POS) Enter pump's direct address (1): (Address that the pump will associate with) Does this pump support dollar auths (Y/N)? y (should be set to yes) Enter Pulses Per GALLONS: 100 (set to 1000) MAX Fuel to be dispensed per transaction: 10 (Largest tank to be filled for this pump) Pump Sentry Options (Y/N)?: Y (optional: electronic pumps usually provide their own pump protection) Pump Sentry: ENABLED Maximum time allowed for fueling (Minutes): 5 Maximum time allowed to retrieve pump handle (Seconds): 60 Maximum time allowed to detect first fueling pulse (Seconds): 60 Maximum time allowed between fueling pulses (Seconds): 30 Set Up Hose 1 (Y/N)? y
Enter Fueltype Code #: 1 (Enter the fuel type code) Enter Tank #: 1 (Enter Tank number – not required for proper operation) Clear Pump Totals (Y/N)? N Enter Totalizer Value: 0.0 (Should set to match fueling point totalizer)
Set Up Hose 2 (Y/N)? N (Only required if pump has more than 1 grade!)
Page 44
Doc. No.: M00-051.00 Rev.: 10
Set Up Hose 3 (Y/N)? N (Must match the pump mapping) Set Up Hose 4 (Y/N)? N Set Up Hose 5 (Y/N)? N Set Up Hose 6 (Y/N)? N Set Up Hose 7 (Y/N)? N Set Up Hose 8 (Y/N)? N
Repeat process to configure each position for each fueling point.

6.3.4 Install PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)

The Install PCT # POS # command tells the system that a PCT position will be used.
Install PCT # POS # (Repeat process to install each configured position)

6.3.5 Install PCT # (# = 1 to 4)

The Install PCT # command tells the system that the PCT is there and to communicate with it.
Install PCT # (Repeat process to install each configured PCT)
Page 44 of 181
Page 45
Doc. No.: M00-051.00 Rev.: 10
Page 45 of 181

6.4 Electronic Pumps Controlled by DPC (Gilbarco)

6.4.1 Install Program

The first step is to define the brand of electronic pumps that will be used and the communication parameters of each. The FSC3000™is designed to support up to eight (8) PCT devices, but DPC is limited to the first four (4) PCTs.
Type: Install program
Install program (or configure program if already been installed) SELECT DPC PROGRAM TO INSTALL
1: GILBARCO / WAYNE
2: GASBOY
ENTER SELECTION: (1)
INSTALLING, PLEASE WAIT... SUCCESSFUL! (Successful should appear after installed) **** DIRECT PUMP SETTINGS –Ver. 10.01D **** Select pump types: 1-Gilbarco, 2-Wayne: (?)1 Select transmission delay: 1-Normal, 2-Short, 3-Shorter, 4-The shortest: (1) Set pump communication port: Baud: 1-1200, 2-2400, 3-4800, 4-5760, 5-9600 -> (5)4 Character size: 1-7 bits, 2-8 bits -> (2)2 Parity: 1-Odd, 2-Even, 3-None -> (3)2 **** DIRECT PUMP VERSION: 10.01D **** Pumps: Gilbarco, Transmission Delay: Normal Baud rate: 5760, Data bits: 8, Parity: Even, Stop bits: 1

6.4.2 Configure PCT # (# = 1 to 4)

The Configure PCT # command defines the PCT that is used for DPC.
Configure PCT # (# = 1 to 4) Is this a K800 PCT or a PCM (Y/N)? N Is this a UPC/DPC (Y/N)? Y

6.4.3 Configure PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)

Configure PCT # POS #
PCT 1 Position 1 (Indicates position being configured) Enter Pump #: 1 (Enter the pump # that is connected to this PCT POS) Enter pump's direct address (1): (Address that the pump will associated with) Select dispenser type: 1-Standard, 2-Without SF, 3-Highline -> (1) (Use Standard unless instructed by Tech Support) Does this pump support dollar auths (Y/N)? y (should be set to yes) Enter Pulses Per GALLONS: 100 (set to 1000) MAX Fuel to be dispensed per transaction: 10 (Largest tank to be filled for this pump) Pump Sentry Options (Y/N)? Y (optional: electronic pumps usually provide their own pump protection) Pump Sentry: ENABLED Maximum time allowed for fueling (Minutes): 5 Maximum time allowed to retrieve pump handle (Seconds): 60 Maximum time allowed to detect first fueling pulse (Seconds): 60 Maximum time allowed between fueling pulses (Seconds): 30 Set Up Hose 1 (Y/N)? Y
Enter Fueltype Code #: 1 (Enter the fuel type code)
Page 46
Doc. No.: M00-051.00 Rev.: 10
Enter Tank #: 1 (Enter Tank number – not required for proper operation) Clear Pump Totals (Y/N)? N Enter Totalizer Value: 0.0 (Should set to match fueling point totalizer)
Set Up Hose 2 (Y/N)? N (Only required if pump has more than 1 grade!) Set Up Hose 3 (Y/N)? N (Must match the pump mapping) Set Up Hose 4 (Y/N)? N Set Up Hose 5 (Y/N)? N Set Up Hose 6 (Y/N)? N Set Up Hose 7 (Y/N)? N Set Up Hose 8 (Y/N)? N
Repeat process to configure each position for each fueling point.

6.4.4 Install PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)

The Install PCT # POS # command indicates to the system that a PCT position will be used.
Install PCT # POS # (Repeat process to install each configured position)

6.4.5 Install PCT # (# = 1 to 4)

This Install PCT # command indicates to the system that the PCT is there and to communicate with it.
Page 46 of 181
Install PCT # (Repeat process to install each configured PCT)
Page 47
Doc. No.: M00-051.00 Rev.: 10

6.5 Electronic Pumps Controlled by DPC (Gasboy)

6.5.1 Install Program

The first step of installation is to define the brand of electronic pumps that will be used and the communication parameters of each pump. The FSC3000™is designed to support up to eight (8) PCT devices, but DPC is limited to the first four (4) PCTs.
Type: Install program
Install program (or Configure program if already installed) SELECT DPC PROGRAM TO INSTALL 1: GILBARCO / WAYNE 2: GASBOY ENTER SELECTION: (2)
INSTALLING, PLEASE WAIT... SUCCESSFUL! (Successful should appear after installed)
**** DIRECT PUMP SETTINGS –Ver. 10.01D **** Select pump types: 1-Gilbarco, 2-Wayne, 3-Gasboy: (1)3 Set pump communication port: Baud: 1-1200, 2-2400, 3-4800, 4-5760, 5-9600 -> (?)5 Character size: 1-7 bits, 2-8 bits -> (1)2 Parity: 1-Odd, 2-Even, 3-None -> (2)3 **** DIRECT PUMP VERSION: 10.01D **** Pumps: Gasboy Baud rate: 9600, Data bits: 8, Parity: None, Stop bits: 1
Page 47 of 181

6.5.2 Configure PCT # (# = 1 to 4)

The Configure PCT # command defines the PCT that is used for DPC.
Configure PCT # (# = 1 to 4) Is this a K800 PCT or a PCM (Y/N)? N Is this a UPC/DPC (Y/N)? Y

6.5.3 Configure PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)

Configure PCT # POS #
PCT 1 Position 1 (Indicates the position being configured) Enter Pump #: 1 (Enter the pump # that is connected to this PCT POS) Enter pump's direct address (1): (Address that the pump will associate with) Enter Pulses Per GALLONS: 100 (set to 1000) MAX Fuel to be dispensed per transaction: 10 (Largest tank to be filled for this pump) Pump Sentry Options (Y/N)?: Y Pump Sentry: ENABLED Maximum time allowed for fueling (Minutes): 5 Maximum time allowed to retrieve pump handle (Seconds): 60 Maximum time allowed to detect first fueling pulse (Seconds): 60 Maximum time allowed between fueling pulses (Seconds): 30 Set Up Hose 1 (Y/N)? y
Enter Fueltype Code #: 1 (Enter the fuel type code) Enter Tank #: 1 (Enter Tank number – not required for proper operation) Clear Pump Totals (Y/N)? N
Enter Totalizer Value: 0.0 (Should set to match fueling point totalizer) Set Up Hose 2 (Y/N)? N (Only required if pump has more than 1 grade!) Set Up Hose 3 (Y/N)? N (Must match the pump mapping) Set Up Hose 4 (Y/N)? N
Page 48
Doc. No.: M00-051.00 Rev.: 10
Set Up Hose 5 (Y/N)? N Set Up Hose 6 (Y/N)? N Set Up Hose 7 (Y/N)? N Set Up Hose 8 (Y/N)? N
Repeat process to configure each position for each fueling point.

6.5.4 Install PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)

The Install PCT # POS # command tells the system that a PCT position will be used.
Install PCT # POS # (Repeat process to install each configured position)

6.5.5 Install PCT # (# = 1 to 4)

The Install PCT # command tells the system that the PCT is there and to communicate with it.
Install PCT # (Repeat process to install each configured PCT)
Page 48 of 181
Page 49
Gasboy Address Side FSC3000 Poll ID
1
1 1 2 2
2
1 3 2 4
3
1 5 2 6
4
1 7 2 8
5
1 9 2 10
6
1 11 2 12
7
1 13 2 14
8
1 15 2 16
9
1 17 2 18
10
1 19 2 20
11
1 21 2 22
12
1 23 2 24
13
1 25 2 26
14
1 27 2 28
15
1 29 2 30
16
1 31 2 32
Doc. No.: M00-051.00 Rev.: 10
Page 49 of 181

6.5.6 DPC – Gasboy Pump Mapping

This table illustrates the configuration of Gasboy pumps in the FSC3000™, as Gasboy uses a different method for mapping pumps. Each Gasboy address represents a two-sided pump. Each side of the pump is to be assigned to a separate FSC3000™Poll ID, as demonstrated.
Page 50
Doc. No.:M00-051.00 Rev.: 10
Page 50 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 51

Section 7 Terminal Setup

Terminals
DTC FIT500 C/OPT
K800
(PV100)
System2
FIT
Change FIT Type (Y/N)? Y Y Y Y Y
Is this a DTC (Y/N)? Y N N N N
Is this a FIT500 (Y/N)? Y N N N
Is this a C/OPT (Y/N)? Y N N
Is this a K800 (Y/N)? Y N
*** (System2 FIT) *** (Default)
Enter Decline Message Timeout seconds: X X X X X
Enter Prompt Timeout Code (1...9): X X X X X
(Enable/Disable) Receipt Printer (Y/N)?X Y O O O
--Enter limit to receive receipts in days (0..99): 2 0 - 99 0 - 99 0 - 99
--Clear Receipt Counter (Y/N)? X X X X
(Enable/Disable) Keyboard Access (Y/N)?X O O O O O
Enter Keyboard Length (1..32): N O
Specify PCTs to shut off on E-Stop (Y/N)?
Change FIT Access to Pumps (Y/N)?
Limit FIT Access to Pumps (Y/N)?
Enter Valid Pumps (p1, p2,...):

7.1 OPW-FMS Fuel Island Terminals

7.1.1 Configure FIT # (1 to 12)

The FSC3000™controller currently supports four (4) terminal types:
Doc. No.: M00-051.00 Rev.: 10
Page 51 of 181
Page 52
Doc. No.: M00-051.00 Rev.: 10
Page 52 of 181
Dedicated Terminal – When FIT access to pumps is limited to one specific pump, the terminal will behave in
the following way:
The FIT will not prompt for pump #.
When the transaction is finished and the terminal is set up for receipts, the terminal will prompt for receipt.
The system will then display what is configured:
Current Type: DTC Terminal
Change FIT Type (Y/N)? N Enter Decline Message Timeout seconds: 15 Enter Prompt Timeout Code (1…9): 1 Issue Receipts (Y/N)? y
--Enter limit to receive receipts in days (0..99): NO Limit
--Clear Receipt Counter (Y/N)? N DISABLE Keyboard Access (Y/N)? N Enter Keyboard Length (1…32): 32 Clear Card Reader Error Counter (Y/N)? N Change FIT Access To Pumps (Y/N)? N
FIT Installed
FIT INFO: CAT
CRIND
CRAD 1.2.5974
Island Terminal: DTC Terminal
Decline Timeout: 15 SECONDS
Prompt Timeout: 15 SECONDS
Receipts: 2 NO Limit To Receive Receipt
Keyboard Access --ENABLED………Length: 32
Card Reader Error Counter: 2
LIST OF VALID PUMPS: 1
Or, if changing the FIT type, then the system will display the following:
Current Type: DTC Terminal
Change FIT Type (Y/N)? y Is this a DTC (Y/N)? Y Is this a FIT500 (Y/N)? Is this a C/OPT (Y/N)? Is this a K800 FIT (Y/N)?
Enter Decline Message Timeout seconds: 15
Enter Prompt Timeout Code (1…9): 1
Issue Receipts (Y/N)? y
--Enter limit to receive receipts in days (0..99): NO Limit
--Clear Receipt Counter (Y/N)? N
DISABLE Keyboard Access (Y/N)? N
Enter Keyboard Length (1…32): 32 Specify PCTs to shut-off on E-Stop (Y/N)? N
Clear Card Reader Error Counter (Y/N)? N
Change FIT Access To Pumps (Y/N)? N

7.1.2 Install FIT # (1 to 8)

This setting indicates to the system that the FIT is available and may communicate with it.
Page 53
Doc. No.: M00-051.00 Rev.: 10

7.2 VIT (Vehicle Identification Terminal) – PetroLink™

When the FSC3000™is equipped with the PetroLink™ option the VIT and its position(s) will need to be configured.

7.2.1 Install VIT x (VIT 1 to 4)

The configuration type and position(s) of each VIT must be defined to activate a specific PCT and position.
Type: Install VIT # <ENTER>
Type 8 (Y/N)? Y (PetroLink uses only type 8 VITs)

7.2.2 Configure VIT # (# = 1 to 4)

The Configure VIT # command can be used to configure all positions on the specific VIT. If desired, configure specific positions using the command “Configure VIT x Position x”.

7.2.3 Configure VIT # POS # (VIT 1 to 4 and POS 1 to 8)

Each VIT and its position must be configured to activate a specific PCT and Position.
Page 53 of 181
Type: Configure VIT # POS # <ENTER>
VIT x POSITION x CONFIGURATION
|- Activate PCT x Position x
|- Authorize with Pump Handle: OFF
|- Maximum Disconnect Time (seconds): 5
|- Status Noise Threshold: 1
Enter new PCT: 1 (Defines which PCT will have a pump activated on) Enter new position: 1 (Enter the position of the PCT to activate when VIU detected) Authorize with Handle ON (Y/N)?: N (Allows pump to turn on even if sensed on immediately) Enter Maximum Disconnect Time (seconds): 5 (Max time for VIT no longer senses VIU) Enter Status Noise Threshold: 1
Repeat the process to configure each VIT position.

7.2.4 Install VIT # POS # (VIT 1 to 4 and POS 1 to 8)

The Install VIT # POS # command indicates to the system that a VIT position will be used.
Repeat the process to install each configured position.
Page 54
Doc. No.:M00-051.00 Rev.: 10
Page 54 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 55
Doc. No.: M00-051.00 Rev.: 10

Section 8 Display Prompts & Receipts

8.1 Dual Language

8.1.1 Set Language

The Dual Language feature allows the System2™ to change its prompts and receipts to another language. When the cards are set up in the buffer, they are assigned a language code. When the card is read by the system it checks the card configuration to determine the language code. From this point on, the terminals will prompt and print receipts in the card-assigned language.
NOTE: Network cards do not support dual language and will use Language 1, except in the
case of receipts.
Dispenser Terminal Control (DTC)-enabled systems use Language 2 to support DTC terminals, messages and prompts must be configured in Artware.
Page 55 of 181
To set Dual Language type: SET LANGUAGE <ENTER>.
Enable DUAL language (Y/N)? Y
--DUAL language Enabled

8.2 Receipts

The Receipts section allows configuration of the receipts header, trailer and body.

8.2.1 Format Receipt Header

The Receipt Header can support up to four (4) lines. The system can define a Header for each language and network receipts. When configuring the network receipt header, never use more than two (2) lines.
To change the receipt header type: Format Receipt Header <ENTER>
Format Receipt Header ENTER Language 1 or 2 or N: Select the desired header (1 - language 1, 2 – language 2, N Network) Enter the header
Line 1 è Line 2 è Line 3 è
(Company name) Invert text (Y/N)? (Company name) Invert text (Y/N)? (Company name) Invert text (Y/N)?
Page 56
Doc. No.: M00-051.00 Rev.: 10
Page 56 of 181

8.2.2 Format Receipt Trailer

The Receipt Trailer can support up to four (4) lines. The system can define a Trailer for each language and network receipts. When configuring Network receipt trailer, never use more than two (2) lines.
To change the receipt trailer type: Format Receipt Trailer.
Format Receipt Trailer ENTER Language 1 or 2 or N: Select the desired trailer (1 - language 1, 2 – language 2, N Network) Enter the Trailer
Line 1 è Line 2 è Line 3 è
(Company name) Invert text (Y/N)? (Company name) Invert text (Y/N)? (Company name) Invert text (Y/N)?

8.2.3 Format Receipt Body

The system allows for the configuration of what is included, not included, the order and text for language 1 or 2 for proprietary receipts. Network receipt bodies are fixed and cannot be changed.
To change the receipt body type: Format Receipt Body.
Line # Language 1 Language 2 Code 1 CARD #: < > < > 1 < 2 CARD #2: < > < > 2 < 3 TRANS #: < > < > 3 < 4 PRODUCT: < > < > 4 < 5 GALLONS: < > < > 5 < 6 PPU: < > < > 6 < 7 TOTAL $ < > < > 7 < 8 DRIVER: < > < > 8 < 9 VEHICLE: < > < > 9 < 10 ACCT NAME: < > < > 10 < 11 SITE ID: < > < > 11 < 12 MISC: < > < > 12 < 13 ODOM: < > < > 13 < 14 MPG: < > < > 14 < 15 LPHKM: < > < > 15 < 16 PUMPÂ # < > < > 16 < 17 ACCOUNT #: < > < 17 <
ENTER (Show, Delete, Insert, exit, Line #):
NOTE: Line 5 defaults to gallons to meet W&M requirements. For non-W&M sites, it is
recommended to reprogram to “QUANTITY:”
Page 57
Doc. No.: M00-051.00 Rev.: 10
Page 57 of 181

8.2.4 Receipt Body Code Variables

Each code represents the information that will be displayed in the receipt body when the receipt is printed. If the transaction does not contain information for the specific transaction receipt, it will be excluded from the body.
Code # Variable Code # Variable
1 Card # 1 18 Additional Prompt A 2 Card # 2 19 Additional Prompt B 3 Transaction # 20 Additional Prompt C 4 Product Name 21 Additional Prompt D 5 Quantity 22 Additional Prompt E 6 Price per Unit 23 Additional Prompt F 7 Total price 24 Additional Prompt G 8 Driver/Single Name 25 Additional Prompt H 9 Vehicle Name 26 Additional Prompt I 10 Account Name 27 Additional Prompt J 11 Site ID 28 Additional Prompt K 12 Miscellaneous Prompt 29 Additional Prompt L 13 Odometer Entry 30 Additional Prompt M 14 MPG 31 Additional Prompt N 15 LPHKM 32 Additional Prompt O 16 Pump # 33 Additional Prompt P 17 Account # 34 Additional Prompt Q
35 Additional Prompt R 36 Additional Prompt S 37 Additional Prompt T 38 Gross Quantity 39 Product Density
NOTE: Use “SHOW PROMPT” to see additional prompt setup. Void is not recommended and
OPW shall not be responsible for communication issues.
NOTE: Codes 38 and 39 are only available when the “bulk plant” flag is enabled.
NOTE: The “>” character functions differently when used with a DTC. When placed at the end
of the message prompt, for example, “Enter Odom>”, the message on the screen is changed to “>” and the first entry upon that first entry. This allows the user to see the entire entry when the display message and entry are too long for the display.
Page 58
Doc. No.: M00-051.00 Rev.: 10
Page 58 of 181

8.3 Prompts

8.3.1 Standard Prompts

The Standard Display Messages guide the customer through the fueling process with a series of prompts. These prompts can be changed as needed, but their functionality cannot. When the customer first approaches the terminals, the terminals will display as follows:
System Open – Display #8 & #9 alternating
System Closed Receipts only – Display #6 & #7 alternating
System Closed – Display #10
NOTE: DTC does not support alternating system open. It only supports displaying 8.
To format a display type: Format display # <ENTER>
Format Display 8 LANGUAGE 1 DISPLAY# 8: ^1^L PETRO VEND^M FUEL CONTROLS Insert a 2 line Display Message (Y/N)? N |Lang 1 | ^1^L PETRO VEND^M FUEL CONTROLS
NOTE: Use “SHOW PROMPT” to see additional prompt setup. Void is not recommended and
OPW shall not be responsible for communication issues.

8.3.2 Format Display Default

The Format Display Default command provides the ability to reload the default display and additional prompts without cold starting the FSC3000™. All previous changes made to the prompts will be completely cleared.
To set Display Type: Format Display Default <ENTER>.
Display TYPE Options: 0 - NO Change 1 - 2x16 2 - 1x40 3 - 2x40 (Graphics) ENTER OPTION: 3 DISPLAY: 2x40 - (GRAPHICS)
NOTE: Sometimes this command must be done twice for the additional prompts to change.
Page 59

8.4 FSC3000™Default Display Prompts

NOTE: To be sure that the correct default display prompts are being utilized, configure using
ARTWare.
Doc. No.: M00-051.00 Rev.: 10
Page 59 of 181
Page 60
Doc. No.: M00-051.00 Rev.: 10
Page 60 of 181
Page 61
Doc. No.: M00-051.00 Rev.: 10
Page 61 of 181
NOTE: Percentage on Prompt 23 displays maximum gallons allowed.
NOTE: The “>” character functions differently when used with a DTC. When placed at the end
of the message prompt, for example, “Enter Odom>”, the message on the screen is changed to “>” and the first entry upon that first entry. This allows the user to see the entire entry when the display message and entry are too long for the display.
Page 62

8.4.1 Graphic Codes

When using graphics displays, the FSC3000™can change font and/or display images.
IMPORTANT: ALL Graphic Codes must be upper-case.
NOTE: Entering ^ {will cause the message to beep when displayed.
Doc. No.: M00-051.00 Rev.: 10
Page 62 of 181
Page 63
Doc. No.: M00-051.00 Rev.: 10
Page 63 of 181
Page 64
Doc. No.: M00-051.00 Rev.: 10

8.4.2 Update Customized Picture Files in the FIT500™

See the FSC operator’s manual for display formatting commands and their usage. Apart from prompt formatting, the FIT500™ allows you to customize pictures to be displayed with a prompt. The following sections explain how to prepare customizable pictures and use them with your system.
8.4.2.1 Display Formatting Commands
To combine a picture with text on the display, add "control character ^" and “picture code” to the graphic prompt.See Section 8.4.1 for details. The picture can be associated with one or more display prompts. For example:
^1 ENTER CARD
The prompt will display picture #1 and the text “ENTER CARD”.
Page 64 of 181
Page 65
Picture Code Picture # File Name
'1'
1 1.bmp
'2'
2 2.bmp
'3'
3 3.bmp
'4'
4 4.bmp
'5'
5 5.bmp
'6'
6 6.bmp
'7'
7 7.bmp
'8'
8 8.bmp
'9'
9 9.bmp
':'
10 10.bmp
';'
11 11.bmp
'<'
12 12.bmp
'='
13 13.bmp
'a'
49 49.bmp
'b'
50 50.bmp
'c'
51 51.bmp
'd'
52 52.bmp
'e'
53 53.bmp
'f'
54 54.bmp
'g'
55 55.bmp
'h'
56 56.bmp
'i'
57 57.bmp
Doc. No.: M00-051.00 Rev.: 10
Page 65 of 181
8.4.2.2 Picture Codes
According to the picture code the appropriate display picture is selected and displayed on screen. Currently, the picture codes are characters from the range ‘1’ to ‘=’ and ‘a’ to ‘i’. According to the codes, OPT pictures are numbered from #1 to #13 and from #49 to #57.
For picture customizable purposes these numbers will be used as the file names of your pictures. The image from the file will replace the embedded picture. See the table below where code, number and file name association is shown.
Page 66
Doc. No.: M00-051.00 Rev.: 10
Page 66 of 181
8.4.2.3 Picture Files
As described above, an appropriate file of the customizable version of the picture can replace each display picture. Windows Bitmap compatible RGB encoded files (.bmp) are currently supported by the FIT500™ system.
You can create a file using any graphic software and save it to the USB storage device. Files must be named according to the picture numbering scheme showed in table. Each customizable file must be placed under
the OPTPicture directory on the device’s drive to be detected by FIT500™ system.
EXAMPLE:
Three customizable files are placed on the storage device:
In this example the FIT500™ system will replace pictures #1, #2 and #10 with their customizable versions for the display prompts using codes ‘^1’, ‘^2’ and ‘^:’.
8.4.2.4 Picture Update
To introduce a new customizable picture to the system:
1. Prepare a file of a picture you want to customize.
2. Save the file to the USB Storage Device.
3. Insert the USB Storage Device into the USB slot of the FIT500™while its software is running.
4. Wait for the picture to be automatically updated.
5. Remove the USB Storage Device from the FIT500™.
NOTE: The main FIT500
update process will run automatically with no user interaction other than inserting the USB Storage Device. The system may run in any state (working or system down) with no restriction to pictures being updated. Several pictures can be updated during one update process.
The customizable pictures will stay on the FIT500™system up to the next update. The USB Storage Device presence is necessary during update process only. You can remove the customizable picture and go back to embedded one by updating the system with a zero-length file of the appropriate file name. The number of customizable picture files can be limited by the internal FIT500’s storage capacity.
software must be running to detect a new picture. The picture
Page 67
Doc. No.: M00-051.00 Rev.: 10
Page 67 of 181
The resolution of the customizable picture depends on the FIT500's display resolution. TheFIT500 currently supports bitmap images of 640 pixels in width by 480 pixels in height (VGA size). Larger images are acceptable but will be reduced to the above size when displayed.

8.5 Additional Prompts

The FSC3000™controller can support Additional Prompts. These additional prompts were originally designed for Network Cards, but can also be used for Proprietary Cards. The additional prompts allow you the ability, just like the other prompts, to change the message. In addition, there is also the option to restrict the number and type of input. The input can be alphanumeric, numeric, alpha numeric (hidden) or yes/no. If dual language is enabled, different messages for language 1 & 2 can be set up Up to eight (8) additional prompts can be assigned to each card/account type, but only nine (9) can be combined presented for a
single transaction with the order of precedence being Account Prompts, Driver/Single and then
Vehicle.
EXAMPLE:
The cards Account is configured for 4 prompts, the Driver card with 4 and Vehicle with 4. When prompted, the 4 account prompts will be presented, the 4 driver card prompt and only the first vehicle card prompt.
NOTE: If using Network Cards, on the system do not modify the prompts used by the specific
networks. In addition, some prompts may need to be changed for a specific network. Reference the following page as needed.
To format additional prompts: Set Prompt <ENTER>.
Page 68
NOTE: The following option is specific to Proprietary Cards ONLY and is NOT supported for
Host-Based Cards.
Enable Minimum Length Prompt entries (Y/N)?
(Card buffer – prompt Seq. must be enable to set this option)
Code Prompt Entry Max Min A ^5^T^KREFER FUEL Y/N: Y/N 1 0 B ^6^T^KODOMETER: 123 6 0 C ^5^T^KTRIP #: ABC 12 0 D ^5^T^LOYALTY CARD #: ABC 2 0 E ^5^T^KPIN: *** 8 0 F ^5^T^KDRIVER ^LID: *** 16 0 G ^5^T^KVEHICLE ^LID: ABC 12 0 H ^5^T^KTRAILER ^LID: ABC 12 0 I ^5^T^KREFER ^LHOURS: 123 5 0 J ^5^T^KDRIVER LICENSE ^LSTATE: ABC 2 0 K ^5^T^KDRIVER LICENSE ^L#: ABC 25 0 L ^5^T^KADDR: BILLING #^LOR HOUSE #: ABC 20 0 M ^5^T^KVEHICLE LICENSE ^L#: ABC 20 0 N ^5^T^KTRAILER LICENSE ^LSTATE: ABC 2 0 O ^5^T^KTRAILER LICENSE ^L#: ABC 20 0 P ^5^T^KDRIVER NAME: ABC 16 0 Q ^5^T^KPURCHASE ^LORDER #: ABC 10 0 R ^5^T^KONTROL #: ABC 12 0 S ^5^T^J5 OR 9 DIGIT ^KZIP CODE: 123 9 0 T ^5^T^KMISC ^KENTRY 123 8 0
ENTER (prompt table row # (A-T) or [RETURN] to exit)
Doc. No.: M00-051.00 Rev.: 10
Page 68 of 181
The table that follows provides a network prompt cross reference chart (if you are processing a card against two networks that can use the same prompt but the chart reflects a different prompt string). You should reformat the specific prompt string to present the dual use need.
Page 69
Doc. No.: M00-051.00 Rev.: 10
Page 69 of 181
Page 70
Doc. No.:M00-051.00 Rev.: 10
Page 70 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 71
Doc. No.: M00-051.00 Rev.: 10
Page 71 of 181

Section 9 Download

When a system first communicates with pump controllers and terminals, it downloads the configuration related to each device. If information is changed after communication has been established with a configured device, the FSC3000™will need to download the configuration again.
All configurations can be downloaded by typing: Download <ENTER>
Device-specific configurations can also be downloaded separately:
Download PCT # (Leave out # to download all PCTs)
Configure PCT # Configure PCT # Position # Set Fueltype – When using DPC and prices are changed, price change on pump must be performed by using download (type: download PCT)
Download FIT # (Leave out # to download all FITs)
Configure FIT # Format Receipt Header Format Receipt Trailer Format Receipt Body Format Display # Format Keyboard #
NOTE: When using the preceding commands, the “Download” command must also be used.
Page 72
Doc. No.:M00-051.00 Rev.: 10
Page 72 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 73
Doc. No.: M00-051.00 Rev.: 10
Page 73 of 181

Section 10 Set Journal

To set up Journal Printer or USB key type: Set Journal <ENTER>.
Is Journal Printer Connected (Y/N)? Y Set Journal Printer Options (Y/N)? Y Print: Account, Driver, Vehicle, Odom, And Misc (Y/N)? Y Account #, Card 2 (Y/N)? Y Prompt Responses (Y/N)? Y Stop Line Skip Between Transactions (Y/N)? Y Journal Error Option (Y/N)? Y Enable Auth On Journal Error (Y/N)? Y Print PCI System Log on First of Month (Y/N)? Y
Replying “Yes” to this prompt will cause the system to automatically print the current PCI log data with the midnight totals of the last day of the month. Once printed, the FSC3000™will automatically clear the log file and start to continuously log system activity again. If set to “No”, see “SHOW LOG” for maintaining compliance.
** USB KEY ** Enter Phoenix Site ID (000 - 998): 001 Allow Auths if USB Key is Not Inserted (Y/N)? Y
NOTE: USB Key support is only available on “REV C” FSC3000™ controller boards.
Page 74
Doc. No.:M00-051.00 Rev.: 10
Page 74 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 75
Doc. No.: M00-051.00 Rev.: 10

Section 11 Show Log (Saving Log)

If an Office Journal is not installed, or it is preferred to not auto print the PCI log, log data must be manually captured and stored to maintain PCI compliance. To manually capture PCI log data, use the following procedure:
1. Connect to the FSC3000™using a Terminal application that provides the ability to capture text. This includes applications such as: HyperTerminal, ARTWare or Phoenix™ applications.
2. Login to the FSC3000™, enable “text capture” and select or define a new file name. Do not overwrite an existing capture file that is not more than one year old.
3. From the command prompt: issue the command “SHOW LOG”.
4. After the log data has been completely displayed, turn off the terminal’s text capture feature.
5. The log file can only be cleared when logged in as the Admin. From the “Admin>” command prompt: issue the “SET ADMIN” command and select the “Clear Event Log” option. This will clear the log flash blank and then log an entry indicating that the clear process occurred.
Page 75 of 181
6. Press “Enter” to exit the “Administrator Menu” and issue “Bye” to log off as the administrator. Make sure all captured logs are saved for a minimum of one year.
NOTE: For more information about the PCI event log and retention requirements of the data
see OPW document “M030001_PA1-PA-DSS-Implementation-Guide.pd,f” Section 8.5.
Page 76
Doc. No.:M00-051.00 Rev.: 10
Page 76 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 77
Transaction Level # of Transactions
2 (Stdandard/default) 500
3 1000
4 2000
5 (Requires 2nd SIMM Card) 4350
Card Memory Level
# Cards & Accounts
Min PCF Options
Avg PCF Options
Max Pcf Options
2 (Standard/default) 2000 2000 2000 2000
3 8000 8000 8000 7580
4 64000 53925 18660 7580
5 (Requires 2nd SIMM Card)
64000+ 150000 60472 24560
Doc. No.: M00-051.00 Rev.: 10
Page 77 of 181

Section 12 FSC3000™Memory Structure

The FSC3000™memory is divided into three (3) sections as defined below.

12.1 Application Memory

This section of memory is used by theFSC3000™for control and storage of the system configuration. The size of this memory space is determined by the firmware version of the fuel site controller. As new features are added the amount of application memory can increase and can change the amount of space available to card/account memory when using memory level 3 or 4.

12.2 Transaction Memory

Transaction Memory is reserved for the storage of fuel transaction records. The number of available stored
transactions is specified when the FSC3000™is purchased.
The FSC3000™can be purchased with the following transaction memory levels:

12.3 Card/Account Memory

The Card/Account Memory is used for storage of the Proprietary Card File. The number of available cards and accounts that can be stored is specified when the FSC3000™is purchased.
TheFSC3000™can be purchased with the following card/account memory levels (table represents memory as of 1.16b):
NOTE: As mentioned above in section 12.1, the maximum amount of card/account records
available will vary as FSC application memory increases. This condition should be considered when purchasing the card memory level to meet your needs.
Page 78
Doc. No.: M00-051.00 Rev.: 10
Page 78 of 181
NOTE: The “Avg PCF Options” counts are based on the following card file options being
enabled:
Account #'s DailyAllocation Card PIN with: Card INVALID after 3 BAD PIN Entries Product Restriction Quantity Restriction Driver / Vehicle / Account Name Additional Prompts (Prompt-Seq.)

12.4 Set Card Buffer (option 1) – Card/Transaction Size

The next step is to set the number of transactions to be stored. The system will display the maximum number of transactions that can be stored based on the transaction level that was purchased. The next step will be to set the card/account size.
To set up Card/Tran buffer type: Set Card Buffer <ENTER>.
1. Specify Card/Tran buffer size
2. Define Card/Account record
3. Clear Card Record Totals
4. Reconcile Card Record Allocation
5. Clear All Account Record Totals
6. Reconcile Account Record Allocation
7. Month End Totals
8. Additional Options
9. Card Record Placement -Buffer A in SIMM 1
10. Trans Record Placement -Buffer B in SIMM 1
X. Exit
Enter Choice: 1
NOTE: Transaction and Message Buffer will be CLEARED!! (Y/N)? Y
Enter # of transactions to be stored (max 2000): (Enter the number that is displayed)
#NOTE: Transaction buffer will be CLEARED!! Are you sure (Y/N)? Y
Enter # of cards to be stored (max xxxxx):
1. Specify Card/Trans buffer size
2. Define Card/Account record
3. Clear Card Record Totals
4. Reconcile Card Record Allocation
5. Clear All Account Record Totals
6. Reconcile Account Record Allocation
7. Month End Totals
8. Additional Options
9. Card Record Placement -Buffer A in SIMM 1
10. Trans Record Placement -Buffer B in SIMM 1
X. Exit
Enter Choice:
Page 79
Doc. No.: M00-051.00 Rev.: 10
Page 79 of 181

12.4.1 Set Card Buffer (option 2) – Card/Account Options

The Card/Account Options define how the card/account file will be set up.
Except for Card Level 2 (2000) and 3 (8000), Card Level 4 (64000) is limited to the number of cards/accounts the system can hold based on the number options defined for the card/accounts.The more options that are assigned, the larger the individual card/account size increases, therefore decreasing the number of card/accounts that can be fit into the card/account buffer (memory).
NOTE: Unless otherwise noted, to modify options, the card buffer must be redefined. You will
need toclear and re-enter all card/account records. Include any of the options that follow in the initial setup if they will be used at a later date.
Available options and how they work are described in the sub-sections that follow:

12.4.2 Account #

When the Account # option is enabled a 4-digit account number can be assigned to each card. An associated account record must also be inserted into the card file. This account number lets you group cards together for reporting purposes and fuel control restriction. When driver/vehicle cards are used with
Accounts enabled, the use of cards assigned to an account is restricted without a corresponding
drive/vehicle card from the same account. If a Driver or Vehicle card is not assigned to an Account (shown as card# being assigned to Account #: 0000), that card is treated as a Maintenance/Global card and is allowed to fuel with any card assigned to any account.
NOTE: This option must be enabled when Tiered Accounts is used.
EXAMPLE:
A driver card assigned to account “0112” can only fuel with a vehicle card assigned to account “0112” or a vehicle card with an account of zero (“0000”). This also holds true in reverse for a Vehicle card.
IMPORTANT: Whenever a driver or vehicle card assigned to a specific account is used with
another card assigned to account zero, fuel totals are accumulated against the assigned account and each of the individual cards.
NOTE: Do Not create an account zero (0000) (and if a card is not assigned to an account)
don’t enter four zeros. Simply skip the entry when prompted for account number.
Page 80
Doc. No.: M00-051.00 Rev.: 10
Page 80 of 181

12.4.3 Expiration Date

The Expiration Date option allows for the definition of a date when each card/account can no longer be used in the system. This option is global and will require all cards/accounts to have the expiration date defined.

12.4.4 Monthly Allocation

The Monthly Allocation option is not recommended for multi-site systems. This option allows for the definition of a monthly monetary amount limit for each card/account. This option is global and will require all cards/accounts to have the amount defined. (See SET CARD – options 3, 4, 5, 6, 7 for more information related to allocation.)

12.4.5 Daily Allocation

The Daily Allocation option allows for the definition of a daily monetary amount for all card/account records. This option is global and will require all cards/accounts to have the amount defined.

12.4.6 PIN #

The PIN # option allows a Personal Identification Number to be assigned to a single and/or driver card. Even with this option enabled, PIN numbers for specific cards can still be disabled.
Card Invalidation:
This option is not available if the PIN # option is not selected. Card Invalidation allows for a card to be deemed automatically invalid when the user enters three (3) consecutive bad PIN numbers. This option can be changed via the re-definition of the card buffer.

12.4.7 Save Odometer Entries

The Save Odometer Entries option is not recommended for multi-site systems. This option allocates space on the card record to store the last transaction odometer entry (Single & Vehicle Cards). This option must be activated for MPG or KM/L calculations to be performed and for the use of the Odometer Reasonability option. If the odometer reasonability option is not being used, then disabling this option is not recommended. This option must be enabled in order to use “Tiered Accounts.”
NOTE: The system can still prompt for odometer entries if this option is not enabled. The
odometer will only be logged into the transaction.
Page 81
Doc. No.: M00-051.00 Rev.: 10
Page 81 of 181

12.4.8 Odometer Reasonability

The Odometer Reasonability option is not recommended for multi-site systems. This option is available when “save odometer entries” is selected. This option allows for the selection of an Odometer restriction code for a Single or Vehicle Card that will reference the Odometer Reasonability Table. When a transaction is performed, the currently entered odometer is checked against the previous stored odometer in the card file. The difference is then compared to the odometer reasonability table with the code defined for that card. If the mileage traveled is equal to or above the lower range and equal to or below the upper range the odometer is considered reasonable and the transaction will continue. If the transaction mileage is higher than the upper limit, or lower than the lower limit, the transaction mileage entry is considered unreasonable and the system will respond in one of two ways. This option must be enabled in order to use “Tiered Accounts”.
Add information when using tiered accounts for the odometer reasonability field.
Accept the third bad entry and fueling is allowed
Reject the third bad entry and terminate transaction
NOTE: Odometer Reasonability Table Setup is required (if applicable).

12.4.9 Product Restriction

The Product Restriction option allows for the definition of a product restriction code to be assigned to each card/account. This code defines which product(s) can be accessed. If product restriction may be needed at a later date, enable this option and assign each card a code 00 for unrestricted.
Common Use: Single Cards (associated to vehicles) and Vehicle Cards (dual-card system) will restrict the
vehicle to the fuel type it uses.
NOTE: Odometer Reasonability Table Setup is required (if applicable).

12.4.10 Quantity Restriction

The Quantity Restriction option allows for the definition of a quantity restriction code for each card/account in order to limit how much fuel each transaction can pump. If Quantity Restriction may be needed at a later date, enable this option and assign each card a code 00 for unrestricted. The Quantity Restriction option can be set up to limit either by quantity or monetary, but not both.
Common Use: Single cards (associated to vehicles) and Vehicle cards (dual-card system) restrict the
transaction from pumping more than the tank size of the vehicle.
NOTE: Quantity Restriction Table Setup is required (if applicable).
Page 82
Doc. No.: M00-051.00 Rev.: 10
Page 82 of 181

12.4.11 Driver/Vehicle/Account Name

The Driver/Vehicle/Account Name option lets you assign up to a nine (9) character entry for each account or card record added.

12.4.12 Verify Prompts 1, 2, 3

The Verify Prompts option allows for three (3) of the additional prompts to be verified against the value set up on the card. This is similar to another PIN number. For a Verified prompt to be presented, its letter must be included in the Prompt Sequence string.
NOTE: Like some of the fleet card hosts, the Verify Prompts option is provided for when the
Proprietary Card File manager needs to track/allow fuel when tied to a specific reference such as; Trip # or P.O. #.

12.4.13 Prompt-Sequence

As discussed in section 8.5 the Prompt-Sequence option allows for eight (8) added prompts for each card type and account. These added prompts can be set up to have a predefined input such as alphanumeric, numeric, yes/no and hidden with a maximum number of inputs. This option is enabled by default if the
Verified Prompts option is enabled.
To set up Card/Account buffer type: Set Card Buffer <ENTER>.
1. Specify Card/Tran buffer size
2. Define Card/Account record
3. Clear Card Record Totals
4. Reconcile Card Record Allocation
5. Clear All Account Record Totals
6. Reconcile Account Record Allocation
7. Month End Totals
8. Additional Options X. Exit
Enter Choice: 2 Card/Account Records: Card/Account storage NOT yet defined Specify Card/Account record (Y/N)? Y
-- Card/Account file will be DESTROYED!!! Sure (Y/N)? Y
ACCOUNT #'S (Y/N)? Y EXPIRATION DATE (Y/N)? Y MONTHLY ALLOCATION (Y/N)? Y DAILY ALLOCATION (Y/N)? Y PIN # (Y/N)? Y
-- CARD INVALID AFTER 3 BAD PIN ENTRIES (Y/N)? Y
SAVE ODOMETER ENTRIES (Y/N)? Y ODOMETER REASONABILITY (Y/N)? Y PUMP RESTRICTION (Y/N)? Y QUANTITY RESTRICTION (Y/N)? Y DRIVER / VEHICLE / ACCOUNT NAME (Y/N)? Y VERIFY 1 (Y/N)? N VERIFY 2 (Y/N)? N VERIFY 3 (Y/N)? N PROMPT-SEQ. (Y/N)? Y Maximum Cards/Accounts: 1911
Page 83
1. Specify Card/Tran buffer size
2. Define Card/Account record
3. Clear Card Record Totals
4. Reconcile Card Record Allocation
5. Clear All Account Record Totals
6. Reconcile Account Record Allocation
7. Month End Totals
8. Additional Options X. Exit
Enter Choice:

12.4.14 Set Card Buffer (option 8) – Additional Options

To set up Additional Options type: Set Card Buffer <ENTER>.
1. Specify Card/Tran buffer size
2. Define Card/Account record
3. Clear Card Record Totals
4. Reconcile Card Record Allocation
5. Clear All Account Record Totals
6. Reconcile Account Record Allocation
7. Month End Totals
8. Additional Options X. Exit
Enter Choice: 8
Doc. No.: M00-051.00 Rev.: 10
Page 83 of 181
Card invalid after 3 BAD PINs (Y/N)?
Discard Leading Zeros on "Prompt_Seq." entries (Y/N)? Y
(Only if Prompt-Seq. in Card/Account record is enabled)
Process ALL Voyager cards as PCF based (Y/N)? Y (IMPORTANT – see below)
Prompt for Odometer on ALL Voyager cards (Y/N)? Y
Prompt for Vehicle Number on ALL Voyager cards (Y/N)? Y (saved as add. prompt)
Mask card number on receipts (Y/N)? Y
Allow keyed cards (Y/N)? Y
- Card valid after 3 BAD PINs
- Leading Zeros Discarded on "Prompt_Seq." Entries.
- All Voyager cards will process as PCF authorized
- Odometer will be prompted for
- Vehicle Number will be prompted for
- Card number will be masked on Receipt
- Keyed entry of Voyager cards allowed
IMPORTANT: “Process ALL Voyager cards as PCF-based” should only be enabled for non-
public sites. Enabling this option will allow every Voyager card to be accepted (offline).
Page 84
Doc. No.:M00-051.00 Rev.: 10
Page 84 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 85
Doc. No.: M00-051.00 Rev.: 10

Section 13 Restrictions and Reasonability

13.1 Set Product Restriction

The Set Products Restriction table is used to define which products are valid for a specific code. This code can then be assigned to a card and/or account. Code 0 is always set to “all products allowed”.
(Option 2) – Card/Account Options
Card/Account Buffer – The “Product Restriction” option must be enabled in order to use this setup option.
To set “Pump Restriction Table” type: Set Product Restriction <ENTER>
Pump Restriction Codes:
CODE 0 ** ALL Products Valid **
CODE 1: Valid Products: NONE
--Specify Code 1 (Y/N/X)? Y
Page 85 of 181
Enter Valid Products (1-32)
è
CODE 2: Valid Products: NONE
--Specify Code 2 (Y/N/X)? N
CODE 14: Valid Products: NONE
--Specify Code 14 (Y/N/X)? N
CODE 15: Valid Products: NONE
--Specify Code 15 (Y/N/X)? N
Page 86
Doc. No.: M00-051.00 Rev.: 10
Page 86 of 181

13.2 Set Quantity Restriction

The Set Quantity Restriction table is where code limits are defined either by currency or volume that can be assigned to a card and/or account. This restriction limits each transaction to the amount assigned to the code. This table can only support all codes as currency or volume limits, but not both. Code 0 is always unrestricted.
(Option 2) – Card Management options
Card/Account buffer – The "Quantity Restriction" option must be enabled in order to use this setup option.
To set Quantity Restriction Table type: Set Quantity Restriction <ENTER>
QUANTITY RESTRICTION CODES:(values represent quantities)
Code 0 No Restrictions Code 1 20 Code 2 40 Code 3 60 Code 4 80 Code 5 100 Code 6 120 Code 7 140 Code 8 160 Code 9 180 Code 10 200 Code 11 220 Code 12 240 Code 13 260 Code 14 280 Code 15 300
Qty restriction value options (Y/N)? N
Page 87
Doc. No.: M00-051.00 Rev.: 10
Page 87 of 181

13.3 Set Odometer Reasonability

The Set Odometer Reasonability table is where the ranges for the odometer reasonability feature are defined. Each code is assigned a minimum and maximum mileage range. This range is then assigned to either Single or Vehicle Cards. When a transaction is performed, the currently entered odometer is checked against the previously stored odometer within the FSC3000™card file. The difference is then compared against the odometer reasonability table with the code defined for that card. If the mileage traveled is equal to or above the lower range and equal to or below the upper range, the odometer is considered reasonable and the transaction will continue. If the transaction mileage is higher than the upper limit, or lower than the lower limit, the transaction mileage entry is considered unreasonable and the system will respond in one of the two ways:
l Accept the third bad entry and fueling is allowed (bad odometer saved)
l Reject the third bad entry and terminate transaction
(Option 2) – Card/Account options
Card/Account Buffer – The "Odometer Reasonability" option must be enabled in order to use this setup option.
NOTE: Code 0 assigned to a card will ignore reasonability.
To set Odometer Reasonability Table type: Set Odometer Reasonability <ENTER>.
1) Enter MINIMUM mileage: 0
2) Enter MAXIMUM mileage: 100
3) Enter MINIMUM mileage: 0
4) Enter MAXIMUM mileage: 250
5) Enter MINIMUM mileage: 0
6) MAXIMUM mileage: 500
14) Enter MINIMUM mileage: 150 Enter MAXIMIM mileage: 700
15) Enter MINIMUM mileage: 150 Enter MAXIMUM mileage: 10000 Change action after BAD Odom entries (Y/N)? y Allow fueling if 3 BAD Odom entries (Y/N)? N
NOTE: PetroLink™ transactions using Odometer Reasonability will always deny fueling
when out of range, irrelevant of the above setting – allow fuel if BAD odometer entry.
In order to use Odometer Entries when Tiered Accounts is enabled, set all minimum values to zero (0) and maximum to nine (9) if Odometer Reasonability and Multiple Locations are not in use. If Odometer Reasonability is in use, then the Tier and Odometer Reasonability table are shared when using codes 1-20.
Page 88
Doc. No.:M00-051.00 Rev.: 10
Page 88 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 89
Doc. No.: M00-051.00 Rev.: 10
Page 89 of 181

Section 14 Card/Account Management

14.1 Media Formats

When a proprietary media (ChipKey®s, magnetic cards, optical cards) is read from a standard terminal, the terminal will match the media’s network number to one of the network numbers configured in the terminal. If there are no matches, the terminal will send the card and network number to the FSC3000™for processing. If the FSC3000™is unable to find a match, the terminal will display “INCORRECT CARD”. All non-proprietary media is sent directly to the FSC3000™for processing. The only exception to this rule is the VIU in which the network is not checked and is sent directly to the FSC3000™for processing. The Format is how the FSC3000™will see the media when read.
ChipKey®:
Proprietary System2 (R/W only) Proprietary K3000L Format – NNNNCCCCCC Proprietary K800 Format – NNNNCCCC (ChipKey R/W) Proprietary K800 Format – NNNNCCCCCC (all other software)
Magnetic Cards:
Proprietary System2 Format – NNNNCCCCCCCCCCCC Proprietary K800 Format – NNNNCCCC Non-Proprietary Format – Track 2 first 19 digits Optical Cards: Proprietary System2 Format – NNNNCCCCCC Proximity: 26 BIT – 5 digit Format – CCCCC 26 BIT – 8 digit Format – FFFCCCCC (FFF = Facility code)
Format – NNNNCCCCCCCCCCCCCCC
NOTE: Other formats could be supported.
VIU (Vehicle Identification Unit):
Keypad:
Format – NNNNCCCCCCCCC
Format – Up to 19 digits (can be limited – Con­figure FIT # Command)
Page 90
Doc. No.: M00-051.00 Rev.: 10
Page 90 of 181

14.2 Special Card Formats (Magnetic Cards)

The FSC3000™normally reads the first 19 digits of track 2 on magnetic cards. There are a few formats that have a custom setup as defined below. When the Magnetic Card is read and the raw data format matches one of the following formats below, the data will be reformatted to a format the card file can recognize.
Format # Raw Card Data Card setup in card file
1 =NNNN=DDDDVVVVAAAAAA=yymmQPLT NNNNDDDDVVVVAAAAAA 2 =NNNN=CCCCCCRRRAAAAAAVVVV=yymmQPP5M NNNNCCCCCCRRRAAAAAA 3 =NNNN=CCCCAAAAVVVV=yymmQP NNNNCCCCAAAAVVVV 4 ==NNNN=CCCCAAAA=====yymm== NNNNCCCCAAAA 5 ==NNNN=========VVVV=====QP NNNNVVVV
Raw card data fields:
=: Field Separator N: System ID D: Driver # V: Vehicle # A: Account # C: Card # R: Participant # yymm: Expiration Date Q: Quantity Restriction Code P: Product Restriction Code L: Price Level Code T: Card Type M: Manual Entry Code "5": Must be in Format 2 Position
Page 91

14.3 Card/Account Adding/Modifying/Deleting

Insert Card
Edit card
Delete card
Insert VIU
Edit VIU
Delete VIU
Insert Account
Edit Account
Delete Account
IMPORTANT: Phoenix™ users should not use the above commands. All Card/Account
management should be performed using the Phoenix™ software interface.
Doc. No.: M00-051.00 Rev.: 10
Page 91 of 181
When using the USB card update function (the USB key flag must be enabled), the card update file on the USB key must have the same site ID as set up in the “Set Journal” command.
File – CUxxx (xxx = phoenix site ID)

14.4 Card/Account Reports

Print/Show <validity><source><category> Card <range>
Validity – Valid / Invalid
Source (If Validity is Invalid) - By Manager / By System (3 bad pins)
Category – Single / Driver / Vehicle
Range - #### / #### - ####
Print/Show Account # (leave out # for all accounts)
Print/Show Card Account #
Print/Show Card Account
Print Show Card Summary
Page 92
Doc. No.:M00-051.00 Rev.: 10
Page 92 of 181
This page intentionally left blank to ensure new
chapters start on right (odd number) pages.
Page 93
Doc. No.: M00-051.00 Rev.: 10
Page 93 of 181

Section 15 Network Management

15.1 Processing of Cards to a Remote Host

The Multi-trucking Network Package for the FSC3000™processes transactions to both private fleet and standard bankcard hosts. From here on these will be referred to as networks. Private fleet networks typically process cards branded to themselves and the FSC only routes those specific cards to their specific network. Other fleet networks will accept another network’s cards through agreements between them. In most scenarios of this type the FSC is able to make these adjustments through setup of the network itself. Bankcard networks (those that accept standard retail cards) such as Visa, MasterCard, Discover and American Express also accept some of the private fleet network cards. The FSC is again prepared to route those cards based on setup. For a list and processing information of the networks currently available under the Multi-trucking Network Package, contact your local sales representative. This section describes the basic setup and configuration needs of the different networks.

15.1.1 Understanding Bank Card Processing

When a bankcard (Visa, MasterCard) is swiped, the FSC will connect to the network and pre-authorize before the cardholder can fuel. Pre-authorization occurs since the final dollar amount of pay-at-the-pump transactions are not known until the end of the sale. Under Visa and MasterCard rules issuing banks place a hold on a card holder’s account for transactions originating from an automated fuel system for $1. From an authorization perspective, For the FSC an the approval of a $1 pre-authorization request allows a transaction of $75 or $150 (depending on card type). These limits are defined by Visa and MasterCard and when dollar authorization is enabled the FSC controls these limits as defined.
See Fleet Table setup under Paymentech Host configuration for more information about configuring $1 authorizations.
NOTE: Currently, the FSC3000 does not support PIN-debit transactions.
Outside of customer specific network support, the FSC currently supports three different networks for the processing of bankcards, BUYPASS (Firstdata), NBS/Bank and Chase Paymentech. By design, only one of these networks can be purchased for use on the FSC at any given time. Enabling more than one of than can create processing concerns and should not be attempted.
Page 94
Doc. No.: M00-051.00 Rev.: 10

15.2 Set Network (Admin Login Rights Required)

The Set Network command displays a menu that begins with network choices (those that are enabled/purchased, up to 7 allowed per site) followed by additional configuration options (8-16) specific to network support.
To Setup Networks type: set network
NETWORK CHOICES
1. ComdataPOS
2. CFN
3. T-CHEK
4. EFS
5. TCH
6. NBS\Bank
8. Set Time Zone
9. Set Fleet Table (Can use “SET FLEET” to access directly)
10. Perform Communication Test
11. Set Forced Trans Capture Time (Set no greater than 18 Minutes)
12. Force Transaction Capture......782 Seconds on Primary Host
13. Print Price and Total on Network Receipts: Yes Display Price on Terminal Display: No
14. Configure Host Port(s) and devices
15. Create Registered Bank Card PINs (“Force Use of Bank Card PINs” is enabled)
16. Synchronize System Clock with Host? No
Page 94 of 181
Enter option number or press [RETURN] to exit: 2
NOTE: Networks (1-6) will only show when enabled.

15.2.1 Set Time Zone (option 8)

The Set Time Zone option allows you to define the time zone where the FSC is installed.
This setting must be configured for any host processing cards under the Universal Network Protocol. These networks currently include: ATIO-Net, Company Card, EFS, Intevacon, KardAll IPN, any NBS (Bank, FMGC, Pacific-Pride, Quarles or QuickFuel), TChek and TCH.

15.2.2 Set Forced Trans Capture Time (option 11)

The Set Forced Trans Capture Time option defines the maximum time in minutes to hold the last un- captured transaction. The system will normally capture the last transaction on the back end of a current transaction authorization to save on dial-outs. Setting this option to low will cause more dial-outs. Never set more than 18 minutes (default 15 minutes). Paymentech requires a transaction capture time be no longer than 20 minutes.
Enter the time interval (in minutes) to force host captures.
Enter ZERO to force a 45 second capture window:
Page 95
Doc. No.: M00-051.00 Rev.: 10
Page 95 of 181
NOTE: This option was originally provided to throttle the number of dial-up phone calls made
when processing cards. With the use of TCP/IP connections now being the norm, the FSC forces this timer to no less than 90 seconds whenever a transactions is completed. Therefore this setting has become a catch all option to ensure transaction captures occur in a timely fashion and it’s recommended to leave the system default of 15mins.

15.2.3 Print Price and Total on Network Receipts (option 13)

The Print Price and Total on Network Receipts option will remove Price and Total on network receipts. This option should always be set to “Yes” when a bankcard network is in use.
NOTE: If you are processing cards to a second network where price and total is not desired,
you can set this option to “No” and then enable printing of price and total under ISO table setup for bankcards.
The second prompt; “Do you want transaction price displayed on terminal (Y/N)?” will cause the FSC to print the price per unit on the terminal when the “Use Pump x” message is shown.

15.2.4 Configure Host Port(s) and Devices (option 14)

The Configure Host Port(s) and Devices option allows for the definition of the type of device used for network connectivity and the enabling of the secondary host and its device for connectivity. The Dual-Host Flag must be enabled for the secondary host to be available (see SHOW FLAGS).
Enter option number or press [RETURN] to exit: 14
Modem setting for Primary Host: New OPW Host modem Port unlocked and usable by all networks.
Change Primary Host device settings (Y/N)? y
1 - Change Modem type/init string 2 - Use TCP/IP connection device 3 - Lock Host Modem to Port
Enter option: 1
Configure init string for Primary Host modem;
'M' for 33.6k baud HOST modem. 'N' new 2400 baud HOST modem (purchased after 6/05). 'O' old 2400 baud HOST modem (prior to 6/05) OR US Robotics. 'C' to configure device specific string.
Enter option: O
Old OPW/US Robotics modem selected!
NOTE: When an Abierto/Systech IP converter is used to process transactions, option ‘O’ for
Old OPW/US Robotics modem should be selected.
Modem setting for Secondary Host: Old OPW/US Robotics Host modem Port unlocked and usable by all networks.
Page 96
Change Secondary Host device settings (Y/N)? y
1 - Change Modem type/init string 2 - Use TCP/IP connection device 3 - Lock Host Modem to Port
Enter option: 3
Is the device specific to:
Company Card processing (Y/N)? N Buypass processing (Y/N)? Y
ENABLE network processing on Secondary Host (Y/N)? y
Secondary Host ENABLED!
NOTE: When using a connection device specifically designed for use with a specific host,
such as the Buypass Micronode, option 3 must be used to lock the processing of a specific hosts activity to that port.
Option 2 (Use TCP/IP connection device) should be used when the IP connection device does not emulate modem functionality. The FSC will not send modem initialization strings, nor expect modem response codes.
Doc. No.: M00-051.00 Rev.: 10
Page 96 of 181
Page 97

15.3 Host Specific Setup Options

This section calls out the setup options that are specific to each host.
l "CFN" on the next page
l "Comdata (Terminal Fuel network, dial-up only)" on page106
l "ComdataPOS" on page108
l "EFS (Original EFS host)" on page110
l "T-Chek" on page112
l "TCH" on page114
l "FleetOne" on page116
l "NBS\FMGC (Fuelman\Gascard [FleetCor])" on page118
l "NBS\BankCard & Quarels Fuel Network" on page121
Doc. No.: M00-051.00 Rev.: 10
Page 97 of 181
l "Paymentech" on page125
l "Buypass" on page134
Page 98
Doc. No.: M00-051.00 Rev.: 10

15.3.1 CFN

When CFN is selected the following options are specific to its setup:
NETWORK option settings NETWORK : CFN
1 - Site ID........................ 9998 (Provided by CFN)
Originator ID.................. 12345678901 (Do not change)
Header String.................. CFN (Do not change unless instructed by CFN)
2 - Card Acceptor Name............. (Same as Site Name on other networks)
3 - Site City......................
4 - Site State.....................
5 - Redial Attempts................ 1
6 - Connect Time......(Seconds).... 30
7 - Local Authorization............ Disabled
8 - Network System................. ON
ON............................. 12:00 AM
OFF............................ 12:00 AM
9 - Authorization Message.......... ^0^FHAVE A SAFE TRIP
10 - Re-Prompt Time....(Minutes).... 10 (set to zero for DTC systems)
11 - Communication Parameters....... 1200/2400 8N1 T60Y
12 - Call Statistics:
Answered: 0 Failed: 0 Busy: 0 Connect Time (secs): 0 13 - Additional Cards Processed:
CFN/Fuelman Dual Network....... Yes (Enabled by default)
T-Chek......................... No
Comdata ComChek................ No
ISO based: (Must be enabled in ISO to process)
MasterCard Fleet............. No
Fuelman & Gascard............ No
Wright Express............... No
14 - Connect after prompts complet.. No
15 - Host Status.................... Host DISABLED
16 - Price/Total on Orig/Legacy Cr.. Yes
Page 98 of 181
Enter option number or press [RETURN] to exit:
1. Site ID
Site ID........................ 9998 (Provided by CFN)
Originator ID.................. 12345678901 (Do not change)
Header String.................. CFN (Do not change unless instructed by CFN)
2-4. Setup Options 2-4
Options 2- 4 should be set up with information from the network. The Technician should contact the Merchant and/or CFN for information.
Like all networks, the “Site ID” is provided by CFN when the site is boarded. The “Originator ID” and “Header String” are optional settings that are transmitted to host. They are available for edit but should not be changed unless specifically directed by CFN.
Redial Attempts
The Redial Attempts option defines how many times the system will try to connect to the network. Default is 1.
6. Connect Time
The Connect Time option defines the maximum time to stay connected to the network when trying to approve a card. If this time is reached, the transaction will be terminated.
Page 99
Doc. No.: M00-051.00 Rev.: 10
Page 99 of 181
Page 100
Doc. No.: M00-051.00 Rev.: 10
Page 100 of 181
7. Local Authorization
The Local Authorization option allows configuration of processing rules if the FSC can authorize network cards offline down the host is down. Not all networks support this feature. If you enable Local Authorization for a specific host you should first confirm with the host that this feature is allowed for the specific site.
NOTE: Depending on the host being configured different options may be presented.
Enter option number or press [RETURN] to exit: 7
Enable LOCAL AUTHORIZATION? (Y/N) : y
Enter NUMBER of Auth allowed (default = 1) : 15 ß number of auth’s allowed Enter DURATION in Mins. (default = 1) : 30 ß number of minutes allowed
Allow KEYED Cards? (Y/N): N ß allowing keyed card numbers can increase risk
To help reduce merchant risk, these settings control how many local authorizations are allowed within the number of minutes configured before local authorization is disabled. Once an active connection has been restored, these counts are cleared and local authorization is again allowed if the host goes down a second time.
If processing cards at a private site or a customer access controlled location, local authorization can be enabled to run forever while a host is down by setting the number of authorizations to zero:
Enable LOCAL AUTHORIZATION? (Y/N) : y
Enter NUMBER of Auth allowed (default = 1) : 0
LOCAL AUTHORIZATION...Infinite
If the network being configured processes bankcards or does not support local authorization the following message is displayed when option 7 is seleted:
Sorry, LOCAL AUTHORIZATION is not allowed for <selected network>
8. Network System (ON/OFF times)
The Network System option defines when a specific network is allowed to process cards at the site (default 24 hours).
9. Authorization Message
The Authorization Message is the message that will be displayed at the terminal after the network card has been approved, when the host itself did not return an authorization message.
10. Re-prompt Time
The Re-Prompt Time option defines how long the system will look back for transactions with the currently swiped card. If a transaction is found, the system will populate certain fields with the same information as before. This setting is useful, for example, when a driver forgets to bring his odometer and must go back to get it. By then the transaction has terminated, he would just re-swipe the card and verify displayed information.
NOTE: Set to 0 (zero) for DTC systems.
Loading...