TECHNICAL DATA
Non-contact temperature measurement of plastic materials and glass surfaces from 0 °C to 710 °C (32 °F to 1310 °F)
Features:
Accurate temperature measurement of thin plastic lm materials like PET, PU, PTFE, PA and glass surfaces
Double laser aiming marks real spot location and spot size up from 1.6 mm at any distance
Optics 45:1 with selectable focus, compact sensor head size
Usable up to 85 °C (185 °F) ambient temperature without cooling and automatic laser switch o󰀨 at 50 °C (122 °F)
Cooling and protection accessories for harsh environmental conditions
General specications
Environmental rating IP 65 (NEMA-4)
Ambient temperature
Storage temperature – 40 °C ... 125 °C (–4 °F ... 257 °F) (sensing head)
Relative humidity 10 – 95 %, non condensing
Vibration IEC 68-2-6: 3 G, 11 – 200 Hz, any axis
Shock IEC 68-2-27: 50 G, 11 ms, any axis
Weight 600 g (21.2 oz) (sensing head)
1)
20 °C ... 85 °C (–4 °F ... 185 °F) (sensing head) (50 °C [122 °F] with laser ON) 20 °C ... 85 °C (–4 °F ... 185 °F) (electronics)
– 40 °C ... 85 °C (–40 °F ... 185 °F) (electronics)
420 g (14.8 oz) (electronics)
Electrical specications
Output / analog
Output / alarm 24 V / 50 mA (open collector)
Optional Relay: 2 x 60 V DC/ 42 V AC
Output / digital USB, RS232, RS485, CAN, Profibus DP, Ethernet
Output impedances mA max. 500 Ω (with 5 – 36 V DC)
Inputs Programmable functional inputs for external
0 / 4
20 mA, 0
– 5
/ 10 V, thermocouple J, K
; 0.4 A;
optically isolated
(optional)
mV min. 100 kΩ load impedance, thermocouple 20 Ω
emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions)
eff
Measurement specications
Temperature range (scalable via programming keys or software)
Spectral range 7.9 μm
Optical resolution (90 % energy)
System accuracy (at ambient temp. 23 ±5 °C) (at ambient tem. 73 ±9 °F)
Repeatability (at ambient temp. 23 ±5 °C) (at ambient tem. 73 ±9 °F)
Temperature resolution (digital) 0.5 K
Exposure time
Emissivity/ Gain (adjustable via programming keys or software)
IR window correction (adjustable via programming keys or software)
Signal processing (parameter adjus­table via software)
Software optris
1)
The functioning of the LCD display may be limited in ambient temperatures
below 0 °C
2)
ε = 1, response time 1 s
3)
Whichever is greater
4)
With dynamic adaptation at low signal levels
2)
4)
(90 % signal) 150 ms
0 °C ... 710 °C (32 °F ... 1310 °F)
45:1
±1 % or ±1.5 °C
(
±1 % or ±2.7 °F3))
±0.5 % or +0.5 °C (±0.5 % or +0.9 °C
0.100 – 1.100
0.100 – 1.000
Peak hold, valley hold, average; extended hold function with threshold and hysteresis
®
Compact Connect
3)
3)
3)
Cable length 3 m (standard), 8 m, 15 m
Power supply 8 – 36 V DC
Current draw max. 160 mA
Laser 635 nm 1 mW, ON/OFF via electronic box or software
(9.8 ft [standard], 26.2 ft, 49.2 ft)
Optris Infrared Sensing, LLC · 200 International Drive, Suite 170 · Portsmouth · NH 03801 USA Phone: 603-766-6060 · E-mail: sales@optris-ir.com · www.optris.com
optris
Optical parameter
®
CTlaser P7
Chart SF optics, D:S = 45:1
SF
27 mm @ 1200 mm (1.06 in @ 47.2 in)
45:1
S
(0.79)
D 0
20
21.7
23.4
25
27
38.4
50
(0.85)
(0.92)
(0.98)
(1.06)
(1.51)
300
600
900
1200
(0)
(11.8)
(23.6)
(35.4)
(47.2)
1500 (59.0)
(1.97)
1800
(70.8)
61.7
(2.43)
2100
(82.7)
(2.89)
(94.5)
Dimensions
Sensing head Electronics
73.4
2400
Further optics, D:S = 45:1
... SF 27 mm @ 1250 mm
... CF1 1.6 mm @ 70 mm
... CF2 3.4 mm @ 150 mm
... CF3 4.5 mm @ 200 mm
mm (in)
mm (in)
... CF4 10 mm @ 450 mm
(1.06 in @ 49.2 in)
(0.06 in @ 2.76 in)
(0.13 in @ 5.91 in)
(0.18 in @ 7.87 in)
(0.39 in @ 17.7 in)
Accessories
Mounting angle, adjustable in two axes (ACCTLAB)
Water cooling and air purge for sensing head (ACCTLW + ACCTLAP)
Cooling housing (ACCJCTL)
Mounting angle for cooling housing, adjustable in two axes (ACCJAB)
Mounting device for cooling housing (ACCTLRM)