optris
®
CTlaser LT
TECHNICAL DATA
Precise focussing and non-
contact temperature measure-
ment from –50 °C to 975 °C
(–58 °F to 1787 °F)
Features:
• Low and high temperature measurements of smallest spots up from 0.9 mm
(0.04 in)
•
Double laser aiming marks real spot location and spot size at any distance
• Optics 75:1 and 50:1 with selectable focus
• CT laser F (fast) for scanning of fast moving low temperature objects up from
9 ms response time
• Usable up to 85 °C (185 °F) ambient temperature without cooling and
automatic laser switch o at 50 °C (122 °F)
• Selectable analog outputs 0/4 – 20 mA, 0 – 5/ 10 V, thermocouple type K or J
• Optional plug in digital interfaces USB, RS232, RS485, CAN or Probus DP
General specications
Environmental rating IP 65 (NEMA-4)
Ambient temperature
Storage temperature – 40 °C ... 125 °C (–4 °F ... 257 °F) (sensing head)
Relative humidity 10 – 95 %, non condensing
Vibration IEC 68-2-6: 3 G, 11 – 200 Hz, any axis
Shock IEC 68-2-27: 50 G, 11 ms, any axis
Weight 600 g (21.2 oz) (sensing head)
1)
– 20 °C ... 85 °C (–4 °F ... 185 °F) (sensing head)
(50 °C [122 °F] with laser ON)
– 20 °C ... 85 °C (–4 °F ... 185 °F) (electronics)
– 40 °C ... 85 °C (–40 °F ... 185 °F) (electronics)
420 g (14.8 oz) (electronics)
Electrical specications
Output / analog
Output / alarm 24 V / 50 mA (open collector)
Optional Relay: 2 x 60 V DC/ 42 V AC
Output / digital USB, RS232, RS485, CAN, Profibus DP, Ethernet
Output impedances mA max. 500 Ω (with 5 – 36 V DC)
Inputs Programmable functional inputs for external
Cable length 3 m (standard), 8 m, 15 m
Power supply 8 – 36 V DC
Current draw (laser) Max. 160 mA
Laser 635 nm 1 mW, ON/OFF via electronic box or software
Channel 1: 0 / 4
Channel 2: sensing head temperature
(– 40 °C ... 85 °C [–40 °F ... 185 °F) as 0 – 5 V or
0 – 10 V), alarm output
optically isolated
(optional)
mV min. 100 kΩ load impedance, thermocouple 20 Ω
emissivity adjustment, ambient temperature
compensation, trigger (reset of hold functions)
(9.8 ft [standard], 26.2 ft, 49.2 ft)
–
20 mA, 0
–
5/ 10 V, thermocouple J, K
; 0.4 A;
eff
Measurement specications
Temperature range
(scalable via programming keys or
software)
Spectral range 8 – 14 μm
Optical resolution
(90 % energy)
Selectable focus
1)
(CTlaser)
System accuracy
(at ambient temp. 23 ±5 °C)
(at ambient tem. 73 ±9 °F)
Repeatability
(at ambient temp. 23 ±5 °C)
(at ambient tem. 73 ±9 °F)
Temperature resolution
(NETD)
Response time
Emissivity/ Gain (adjustable
via sensor or software)
IR window correction
(adjustable via software)
Signal processing (parameter adjustable via software)
Software optris
1)
The functioning of the LCD display may be limited in ambient temperatures
below 0 °C
2)
Different spotsizes for CTlaser F (D:S = 50:1)
3)
Whichever is greater
4)
At object temperatures >0 °C, ε = 1
5)
With dynamic adaption at low signal levels
2)
5)
(90 % signal) 9 ms CTlaser F / 120 ms CTlaser
–50 °C ... 975 °C
(–58 °F ... 1787 °F)
75:1 CTlaser
50:1 CTlaser F
CF1: 0.9 mm @ 70 mm (0.04 in @ 2.76 in)
CF2: 1.9 mm @ 150 mm (0.07 in @ 5.91 in)
CF3: 2.75 mm @ 200 mm (0.11 in @ 7.87 in)
CF4: 5.9 mm @ 450 mm (0.23 in @ 17.7 in)
SF: 16 mm @ 1200 mm (0.63 in @ 47.2 in)
±1 % or ±1 °C
±1.5 % or ±1.5 °C
(±1 % or ±1.8 °F
(±1.5 % or ±2.7 °F
±0.5 % or ±0.5 °C
±1 % or ± 1 °C
(±0.5 % or ±0.9 °F)
(±1 % or ±1.8 °F)
0.1 K / 0.5 K with CTlaser F
0.100 – 1.100
0.100 – 1.000
Peak hold, valley hold, average; extended hold
function with threshold and hysteresis
3),4)
(CTlaser)
3),4)
3),4)
[CTlaser])
3),4)
2),3)
2),3)
(CTlaser F)
2),3)
2),3)
®
Compact Connect
(CTlaser F)
[CTlaser F])
(CTlaser)
(CTlaser)
(CTlaser F)
Optris Infrared Sensing, LLC · 200 International Drive, Suite 170 · Portsmouth · NH 03801 USA