Optris CTlaser F2 Specifications

optris
®
CTlaser F2/F6
TECHNICAL DATA
Non-contact temperature measurement of CO2 and CO ame gases up to 1650 °C (2912 °F)
Features:
Accurate temperature measurement of CO
range of 200 °C (392 °F) up to 1650 °C (2912 °F) in combustion processes, garbage burning or processes inside chemical reactors
Double laser aiming marks real spot location and spot size up from 1.6 mm (0.06 in) at any distance
Optics 45:1 with selectable focus, compact sensor head size
Usable up to 85 °C (185 °F) ambient temperature without cooling and automatic laser switch o󰀨 at 50 °C (122 °F)
Cooling and protection accessories for harsh environmental conditions
Calibrated under inert gas atmosphere (Argon)
General specications
Environmental rating IP 65 (NEMA-4) front mountable
Ambient temperature
Storage temperature – 40 °C ... 125 °C (–4 °F ... 257 °F) (sensing head)
Relative humidity 10 – 95 %, non condensing
Vibration IEC 68-2-6: 3 G, 11 – 200 Hz, any axis
Shock IEC 68-2-27: 50 G, 11 ms, any axis
Weight 600 g (21.2 oz) (sensing head)
1)
at vacuum processes (up to 10
20 °C ... 85 °C (–4 °F ... 185 °F) (sensing head) (50 °C [122 °F] with laser ON) 20 °C ... 85 °C (–4 °F ... 185 °F) (electronics)
– 40 °C ... 85 °C (–40 °F ... 185 °F) (electronics)
420 g (14.8 oz) (electronics)
–3
mbar)
Electrical specications
Output / analog
Output / alarm 24 V / 50 mA (open collector)
Optional Relay: 2 x 60 V DC/ 42 V AC
Output / digital USB, RS232, RS485, CAN, Profibus DP, Ethernet
Output impedances mA max. 500 Ω (with 5 – 36 V DC)
Inputs Programmable functional inputs for external
Cable length 3 m (standard), 8 m, 15 m
0 / 4
20 mA, 0
– 5
/ 10 V, thermocouple J, K
; 0.4 A;
optically isolated
(optional)
mV min. 100 kΩ load impedance, thermocouple 20 Ω
emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions)
(9.8 ft [standard], 26.2 ft, 49.2 ft)
eff
(F2) or CO (F6) ame gases in the
2
Measurement specications
Temperature range (scalable via programming keys or software)
Spectral range 4.24 μm (F2)
Optical resolution (90 % energy)
System accuracy (at ambient temp. 23 ±5 °C) (at ambient tem. 73 ±9 °F)
Repeatability (at ambient temp. 23 ±5 °C) (at ambient tem. 73 ±9 °F)
Temperature resolution (digital) 0.1 K
Exposure time
Emissivity/ Gain (adjustable via sensor or software)
IR window correction (adjustable via software)
Signal processing (parameter adjus­table via software)
Software optris
1)
The functioning of the LCD display may be limited in ambient temperatures
below 0 °C
2)
At ambient temperatures >300 °C (572 °F)
3)
ε = 1, response time 1 s
4)
Whichever is greater
5)
With dynamic adaptation at low signal levels
5)
(90 % signal) 10 ms
200 °C ... 1450 °C (F2 / F6) (392 °F ... 2642 °F [F2 / F6]) 400 °C ... 1650 °C (F2H / F6H) (752 °F ... 2912 °F [F2H / F6H])
4.64 μm (F6)
45:1
2) 3)
±1 %
±0.5 % or +0.5 °C
(
±0.5 % or +0.9 °F
0.100 – 1.100
0.100 – 1.000
Peak hold, valley hold, average; extended hold function with threshold and hysteresis
®
Compact Connect
3) 4)
3) 4)
)
Power supply 8 – 36 V DC
Current draw max. 160 mA
Laser 635 nm 1 mW, ON/OFF via electronic box or software
Optris Infrared Sensing, LLC · 200 International Drive, Suite 170 · Portsmouth · NH 03801 USA Phone: 603-766-6060 · E-mail: sales@optris-ir.com · www.optris.com
optris
Optical parameter
®
CTlaser F2/F6
Chart SF optics, D:S = 45:1
7.3 mm @ 1100 mm 05M SF 150:1
S
D 0
20 (0.79)
(0)
16.5
(0.65)
300
(11.8)
(0.51)
(23.6)
600
9.6
7.3
13.5
17.3
23.5
13
(0.36)
900
(35.4)
(0.29)
1100
(43.3)
(0.53)
1350
(53.1)
(0.68)
1500
(59.0)
(0.93)
1750
(68.9)
30
(1.18)
2000
(78.7)
mm (in)
mm (in)
Dimensions
Sensing head Electronics
Further optics, D:S = 45:1
... SF 27 mm @ 1250 mm
(1.06 in @ 49.2 in)
... CF1 1.6 mm @ 70 mm
(0.06 in @ 2.76 in)
... CF2 3.4 mm @ 150 mm
(0.13 in @ 5.91 in)
... CF3 4.5 mm @ 200 mm
(0.18 in @ 7.87 in)
... CF4 10 mm @ 450 mm
(0.39 in @ 17.7 in)
Accessories
Mounting angle, adjustable in two axes (ACCTLAB)
Water cooling and air purge for sensing head (ACCTLW + ACCTLAP)
Cooling housing
(ACCJCTL)
Mounting angle for cooling housing, adjustable in two axes (ACCJAB)
Mounting device for cooling housing
(ACCTLRM)
Specications are subject to change without notice · CTlaser F2/F6-US2018-08-A