TECHNICAL DATA
Precise non-contact temperature measurement of liquid metals from 1000 °C to 2000 °C (1832 °F to 3632 °F)
Features:
Precise temperature measurement of molten metal
Decrease of measurement errors at emissivity changes or wrong settings thanks to short wavelength of 525 nm
Temperature range from 1000 °C to 2000 °C (1832 °F to 3632 °F), measuring
elds from 1 mm (0.04 in) and exposure times from 1 ms
Suited for ambient temperatures of 85 °C (185 °F) without additional cooling,
laser switches of automatically at 50 °C (122 °F)
Optical resolution 150:1, focus settings scalable
Double laser visor with 2 laser beams for exact measuring eld marking and
focussing
General specications
Environmental rating IP 65 (NEMA-4) front mountable
Ambient temperature
Storage temperature – 40 °C ... 125 °C (–4 °F ... 257 °F) (sensing head)
Relative humidity 10 – 95 %, non condensing
Vibration IEC 68-2-6: 3 G, 11 – 200 Hz, any axis
Shock IEC 68-2-27: 50 G, 11 ms, any axis
Weight 600 g (21.2 oz) (sensing head)
1)
at vacuum processes (up to 10
20 °C ... 85 °C (–4 °F ... 185 °F) (sensing head) (50 °C [122 °F] with laser ON) 20 °C ... 85 °C (–4 °F ... 185 °F) (electronics)
– 40 °C ... 85 °C (–40 °F ... 185 °F) (electronics)
420 g (14.8 oz) (electronics)
–3
mbar)
Electrical specications
Output / analog
Output / alarm 24 V / 50 mA (open collector)
Optional Relay: 2 x 60 V DC/ 42 V AC
Output / digital USB, RS232, RS485, CAN, Profibus DP, Ethernet
Output impedances mA max. 500 Ω (with 8 – 36 V DC)
Inputs Programmable functional inputs for external
0 / 4
20 mA, 0
– 5
/ 10 V, thermocouple J, K
; 0.4 A;
optically isolated
(optional)
mV min. 100 kΩ load impedance, thermocouple 20 Ω
emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions)
eff
Measurement specications
Temperature range (scalable via programming keys or software)
Spectral range 525 nm
Optical resolution (90 % energy)
System accuracy (at ambient temp. 23 ±5 °C) (at ambient tem. 73 ±9 °F)
Repeatability (at ambient temp. 23 ±5 °C) (at ambient tem. 73 ±9 °F)
Temperature resolution (digital) 0.2 K
Exposure time
Emissivity/ Gain (adjustable via sensor or software)
IR window correction (adjustable via software)
Signal processing (parameter adjus­table via software)
Software optris
1)
The functioning of the LCD display may be limited in ambient temperatures
below 0 °C
2)
ε = 1, Exposure time 1 s
3)
With dynamic adaptation at low signal levels
2)
3)
(90 % signal) 1 ms
1000 °C ... 2000 °C (1832 °F ... 3632 °F)
150:1 (3ML)
±1 % of reading (≤1100 °C) ±(0.3 % of reading +2 °F) (>1100 °C) ±1 % of reading (≤2012 °F) ±(0.3 % of reading +3.6 °F) (>2012 °F)
±0.5 % of reading (≤1100 °C) ±(0.1 % of reading +1 °C) (>1100 °C) ±0.5 % of reading (≤2012 °F) ±(0.1 % of reading +1.9 °F) (>2012 °F)
0.100 – 1.100
0.100 – 1.000
Peak hold, valley hold, average; extended hold function with threshold and hysteresis
®
Compact Connect
Cable length 3 m (standard), 8 m, 15 m
Current draw (laser) Max. 160 mA
Power supply 8 – 36 V DC
Laser 635 nm 1 mW, ON/OFF via electronic box or software
(9.8 ft [standard], 26.2 ft, 49.2 ft)
Optris Infrared Sensing, LLC · 200 International Drive, Suite 170 · Portsmouth · NH 03801 USA Phone: 603-766-6060 · E-mail: sales@optris-ir.com · www.optris.com
optris
Optical parameter
®
CTlaser 05M
7.3 mm @ 1100 mm (0.29 in @ 43.3 in)
05M SF 150:1
S
D 0
20 (0.79)
(0)
16.5
(0.65)
300
(11.8)
13
(0.51)
600
(23.6)
9.6
(0.38)
900
(35.4)
7.3
(0.29)
1100
(43.3)
13.5
(0.53)
1350
(53.1)
17.3
(0.68)
1500
(59.0)
23.5
(0.93)
1750
(68.9)
30
(1.18)
2000
(78.7)
mm (in)
mm (in)
Dimensions
Sensing head Electronics
24 mm @ 3600 mm (0.94 in @ 142 in)
05M FF 150:1
S
D 0
20 (0.79)
(0)
21
(0.83)
900
(35.4)
22
(0.87)
1800
(70.8)
23
(0.91)
2700 (106)
24
(0.94)
3600 (142)
29
41
53.4
62.5
(1.14)
(1.61)
(2.10)
4000
5000
(158)
(197)
6000
(236)
(2.46)
6730
(265)
mm (in)
mm (in)
Accessories
Mounting angle, adjustable in two axes (ACCTLAB)
Water cooling and air purge for sensing head (ACCTLW + ACCTLAP)
Cooling housing (ACCJCTL)
Mounting angle for cooling housing,
adjustable in two axes (ACCJAB)
Mounting device for cooling housing
(ACCTLRM)
Specications are subject to change without notice · CTlaser 05M-US2018-08-A