Optris CTex Operating Manual

optris® CTex LT
Operators Manual - Addendum
___________________________________________________________________________________

Manufacturer’s declaration for the CTex measurement system

The CTex sensing head can be used as a passive element in hazardous areas. The operator has to verify the classification of the optris CT sensing heads, according to EN 60079-0/ EN 60079-11 (category of simple electrical devices) on his own. To verify that the CT sensing head is a simple electrical device according to EN 60079-11 item 5.7 we hereby confirm the following technical data:
Inductance (available for the sensor cable only):
Inductance of the loops min. 0.55 mH/ km; max 0.56 mH/ km In relation to a cable length of 15 m: Inductance of the loops min. 0.825 *10-3 mH; max 0.84 *10-3 mH
Capacitance:
Capacitance of the sensor cable: Capacitance lead/ lead min. 16.5 nF/ km; max. 17.9 nF/ km Capacitance lead/ rest min. 101.0 nF/ km; max. 103.4 nF/ km In relation to a cable length of 15 m: Capacitance lead/ lead min. 0.2475 nF; max. 0.2685 nF Capacitance lead/ rest min. 1.515 nF; max. 1.551 nF Capacitance in the sensing head: C1 = Ceramic SMD Capacitor 6.8 nF +/- 20 % C2 = Ceramic SMD Capacitor 6.8 nF +/- 20 %
optris® CTex LT
For further information of the CTex sensing head in relation to the appropriate components

Technical Data

Connection diagram

Figure 1: Connection diagram

Specifications

contact our service department.
Optris GmbH
Ferdinand-Buisson-Str. 14 · D-13127 Berlin · Germany Tel: +49(0)30 500 197 0 · Fax: +49(0)30 500 197 10 E-mail: info@optris.de · Internet: www.optris.de
optris CT-exMAD-E2014-11-A
Loading...