optris
®
CTlaser 3M
TECHNICAL DATA
Non-contact temperature
measurement with precise
aiming from 50 °C to 1800 °C
Features:
• Accurate temperature measurements of metals, secondary metal processing
and ceramic materials
• Double laser aiming marks real spot location at any distance
• Optical resolution up to 300:1 with selectable focus
• Temperature ranges from 50 °C to 1800 °C, with selectable focus Temperature
ranges from 50 °C to 1800 °C, measuring spots up from 0.7 mm and response
times up from 1 ms
• Usable up to 85 °C ambient temperature without cooling
• Short measuring wave length of 2.3 μm reduces error of temperature readings
on surfaces with low or unknown emissivity
General specications
Environmental rating IP 65 (NEMA-4)
Ambient temperature
Storage temperature – 40 °C ... 125 °C (sensing head)
Relative humidity 10 – 95 %, non-condensing
Vibration (sensor) IEC 68-2-6: 3 G, 11 – 200 Hz, any axis
Shock (sensor) IEC 68-2-27: 50 G, 11 ms, any axis
Weight 600 g (sensing head) / 420 g (electronics)
1)
–20 °C ... 85 °C (sensing head, 50 °C with laser ON)
–20 °C ... 85 °C (electronics)
– 40 °C ... 85 °C (electronics)
Electrical specications
Outputs / analog
Outputs / alarm 24 V / 50 mA (open collector)
Optional Relay: 2 x 60 V DC / 42 V AC
Outputs / digital USB, RS232, RS485, CAN, Profibus DP, Ethernet
Output impedances mA max. 500 Ω (with 5 – 36 V DC)
Inputs Programmable functional inputs for external
Cable length 3 m (standard), 8 m, 15 m
Power Supply 8 – 36 V DC
Current draw Max. 160 mA
Laser 635 nm 1 mW, ON/OFF via electronic box or software
0 / 4
–
20 mA, 0
– 5
/ 10 V, thermocouple J, K
; 0.4 A;
optically isolated
(optional)
mV min. 100 kΩ load impedance
thermocouple 20 Ω
emissivity adjustment, ambient temperature
compensation, trigger (reset of hold functions)
eff
Measurement specications
Temperature range2)
(scalable via programming
keys or software)
Spectral range 2.3 μm
Optical resolution
(90 % energy)
System accuracy
(at ambient temp. 23 ±5 °C
[73 ±9 °F])
Repeatability
(at ambient temp. 23 ±5 °C
[73 ±9 °F])
Temperature resolution
(digital)
Exposure time
Emissivity/ Gain
(adjustable via programming
keys or software)
Transmissivity/ Gain
(adjustable via programming
keys or software)
Signal processing (parameter
adjustable via programming
keys or software, respectively)
Software optris
1)
The functioning of the LCD display may be limited in ambient temperatures
below 0 °C
2)
T
>T
object
3)
Specification valid at T
4)
ε = 1, response time 1 s
5)
With dynamic adaptation at low signal levels
4)
5)
(90 % signal) 1 ms
+25 °C
sensing head
50 °C ... 400 °C (3ML)
100 °C ... 600 °C (3MH)
150 °C ... 1000 °C (3MH1)
200 °C ... 1500 °C (3MH2)
250 °C ... 1800 °C (3MH3)
60:1 (3ML)
100:1 (3MH)
300:1 (3MH1 – 3MH3)
±(0.3 % of reading +2 °C)
±(0.1 % of reading +1 °C)
0.1 K
0.100 – 1.100
0.100 – 1.100
Peak hold, valley hold, average; extended hold
function with threshold and hysteresis
®
Compact Connect
≥ start of measurement range +50 °C
object
3)
3)
3)
Optris GmbH · Ferdinand-Buisson-Str. 14 · 13127 Berlin · Germany
Phone: +49 (0)30 500 197-0 · Fax: +49 (0)30 500 197-10 · E-mail: sales@optris.com · www.optris.com

optris
Optical specications
®
CTlaser 3M
3MH SF / 100:1
11 mm @ 1100 mm
far eld: 36:1
far eld: 30:1
16.3 mm @ 1100 mm
3ML SF
/
60:1
3MH CF1 / 100:1
0.85 mm @ 85 mm
far eld: 4:1
far eld: 4:1
1.4 mm @ 85 mm
3ML CF1
/ 60:1
S 20 19 18 17 16 15 14 12 11 13 16 20 28 38
S 20 20 20 20 20 19 19 19 18.3 19 25 30 40 53
D 0 150 300 450 600 750 900
S2011.0 0.85 9.5
S2011.3 1.4 10.3
D 0 40 85 120 150 200 250 300 400 500 600 700 800
16.8 29.1 41.4 53.6 78.2 103 128 152 177
17.8 30.4 43 56 81 106 132 157 182
10001100 1200 1350
1500 1750 2000
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
3MH CF3 / 100:1
2 mm @ 200 mm
far eld: 9:1
far eld: 8:1
4.3 mm @ 200 mm
3ML CF3
3MH CF4 / 100:1
4.5 mm @ 450 mm
far eld: 19:1
far eld: 17:1
7.5 mm @ 450 mm
3ML CF4
/
60:1
/
60:1
S 20 15.5 11 6.5 2 7.5 13 24 35 46 57 68
S 20 16 11.7 7.6 3.4 9.3 15.1 27 39 51 62 74
D 0 50 100 150 200 250 300 400 500 600 700 800
S 20 18.3 16.6 14.9 13.2 11.4 9.7 8 6.3 4.5 7.3 13 19 24
S 20 18.7 17.3 15.9 14.5 13.1 11.7 10.3 9 7.5 10.6 17 23 29
D 0 50 100 150 200 250 300
350 400 450 500
600 700 800
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
3MH CF2 / 100:1
2 mm @ 200 mm
far eld: 9:1
far eld: 8:1
4.3 mm @ 200 mm
3ML CF2
/
60:1
S 20 14 7.7 1.5 8.7 16 23 38 52 66 81 95
S 20 14.2 8.4 2.5 10 17.5 25 40 55 70 85 100
D 0 50 100 150 200 250 300 400 500 600 700 800
(mm)
(mm)
(mm)
Dimensions
Sensing head Electronics
Further optics, D:S = 300:1
... SF 3.7 mm @ 1100 mm
... CF2 0.5 mm @ 150 mm
... CF3 0.7 mm @ 200 mm
... CF4 1.5 mm @ 450 mm
... FF 12 mm @ 3600 mm
Specications are subject to change without notice · CTlaser 3M-E2018-08-A