optris
®
CSlaser LT
TECHNICAL DATA
Two-wire infrared
thermometer for temperature measurement from
–30 °C to 1000 °C
(– 22°F to 1832 °F)
Features:
• Temperature range from –30 °C to 1000 °C (– 22 °F to 1832 °F), measuring spots
up from 1.4 mm (0.06 in) and response times up from 150 ms
• Single-piece, robust design for easy installation into your process system
• Standard two-wire interface for reliable data transfer and easy integration into
a PLC
• Innovative double-laser sighting for exact marking of measurement targets
• Fast sensor parameterisation and real-time measurement via USB
• Dependable in ambient temperatures up to 85 °C (185 °F) without additional
cooling
• Wide power range: 5 – 28 V DC
General specications
Environmental rating IP 65 (NEMA-4) front mountable
at vacuum processes (up to 10
Ambient temperature –20 °C to 85 °C (–4 °F to 185 °F)
(50 °C (122 °F) with laser ON)
Storage temperature –40 °C to 85 °C (–40 °F to 185 °F)
Relative humidity 10 – 95 %, non condensing
Vibration IEC 68-2-6: 3 G, 11 – 200 Hz, any axis
Shock IEC 68-2-27: 50 G, 11 ms, any axis
Weight 600 g (21.2 oz)
–3
mbar)
Electrical specications
Output / analog 4 – 20 mA
Loop resistance Max. 1000 Ω
1)
Measurement specications
Temperature range
(scalable via software)
Spectral range 8 – 14 μm
Optical resolution
(90 % energy)
System accuracy
(at T
= 23 ±5 °C) (73 ±9 °F)
amb
Repeatability
(at T
= 23 ±5 °C) (73 ±9 °F)
amb
Temperature resolution 0.1 K
Response time (90 % signal) 150 ms
Emissivity/ Gain (adjustable
via sensor or software)
IR window correction
(adjustable via software)
Signal processing (parameter
adjustable via software)
Software optris
1)
In dependence on supply voltage
2)
Whichever is greater
–30 °C to 1000 °C (–22 °F to 1832°F)
50:1
±1 % or ±1 °C
(±1 % or ±1.8 °F)
±0.5% or ±0.5 °C
(±0.5 % or ±0.9 °F)
0.100 – 1.100
0.100 – 1.000
Peak hold, valley hold, average; extended hold
function with threshold and hysteresis
®
Compact Connect
2)
2)
Output / alarm 0 – 30 V / 500 mA
Output / digital Uni-/ bidirectional, 9.6 kBaud,
Cable length
(connector version only)
Current draw (laser) 45 mA at 5 V
Power supply 5 – 30 V DC
(open collector)
0/3 V Pegel, USB optional
3 m / 8 m / 15 m (9.8 ft / 26.2 ft / 49.2 ft)
20 mA at 12 V
12 mA at 24 V
Optris Infrared Sensing, LLC · 200 International Drive, Suite 170 · Portsmouth · NH 03801 USA
Phone: 603-766-6060 · E-mail: sales@optris-ir.com · www.optris.com
optris
Optical parameter
20
S
(0.79)
D 0
(0)
Connections
®
CSlaser LT
21
22
23
(0.83)
300
(11.8)
(0.87)
600
(23.6)
(0.91)
900
(35.4)
24
(0.94)
1200
(47.2)
35
(1.38)
1500
(59.1)
46
(1.81)
1800
(70.9)
57
(2.24)
2100
(82.7)
68
(2.68)
2400
(94.5)
mm
(in)
mm
(in)
CSlaser LT opticsSF optics, D:S = 50:1, 24 mm @ 1200 mm (0.94 in @ 47.2 in)
... SF 24 mm @ 1200 mm (0.94 in @ 47.2 in)
... CF1 1.4 mm @ 70 mm (0.06 in @ 2.76 in)
... CF2 3 mm @ 150 mm (0.12 in @ 5.91 in)
... CF3 4 mm @ 200 mm (0.16 in @ 7.87 in)
... CF4 9 mm @ 450 mm (0.35 in @ 17.7 in)
Analog mode
of operation
Digital mode
of operation
Dimensions
Dimensions CSlaser LT
Loop +
Laser +
RxD
Loop –
Laser –
Shield
Loop +
Laser +
TxD
RxD
Loop –
Laser –
Shield
4 – 20 mA
0 – 30 V DC / 500 mA
5 V DC [white]
IN [yellow]
OUT [green]
GND [brown]
Shield [black]
5 – 28 V DC
+
–
PC
Electrical connections /
emissivityadjustment
(sensor back side)
Specications are subject to change without notice · CSlaser LT-E2018-08-A