OPTO TECH CORPORATION TP337A Datasheet

THERMOPILE
Part No : 80-02-00013
Features
Type : TP337A
The thermopile sensor consists of a series of 116 thermoelements, forming a sensitive region size of 545μm (diameter). The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5 m wavelength. The thermosensor exhibits an almost white noise, comparable to an ohmic resistance. It has a constant signal versus frequency up to its frequency limit, and is directly proportional to incident radiation. The thermopile sensors are featured with an additional temperature reference resistor on the same chip. The standard version of temperature reference resistor is housing connected to ground.
Applications
* Ear thermometers; clinic thermometers
* Infrared thermometers
* Consumer applications: hair dryer, micro-wave oven, air conditioner, refrigerator
μ
* Continuous temperature control of manufacturing
* Security system
* Radiation monitor switch system
* Absorbing measurement for gas analysis
* Thermoelectric converter
* Heat flux flowmeter
OPTO TECH
Since 1983
Microelectronics Business Division 2003.01 1 / 7
OPTO TECH CORPORATION
THERMOPILE
Part No : 80-02-00013
Electrical Characteristics
Type : TP337A
Parameter Condition Min. Typ. Max. Unit
Thermopile
Number of thermojunctions --- 116 ---
Chip size --- 1740*1740 ---
Active region size
Thickness of substrate
Resistance of thermopile 25℃ 50 65 80
Sensitivity
Interference layer
Silicon-substrat e
With 5-14μm filter
---
600 625 650 μm
70 85 100 V/W
Diameter
545
---
μ
μ
m2
m
Detecctivity 1.0*10
Time constant --- 16 --- ms
Noise voltage 28 32 36 nV/Hz
NEP 0.28 0.36 0.48 nW/Hz
Temperature range Operation -20 --- 100
T emperature refe rence resistor
Resistance (1) 25℃ 29.1 30.0 30.9 KΩ
β
value (1) 0
---
o
C/50℃ 3773 3811 3849 K
8
1.3*108 1.7*108 cm*Hz
1/2
/W
1/2
1/2
Measured at 1 Hz chopper frequency, within spectral range 5-14μm, using a blackbody radiator of 500K temperature.
Note : Thermistor should be operated under 1mA.
OPTO TECH
Since 1983
Microelectronics Business Division 2003.01 2 / 7
OPTO TECH CORPORATION
THERMOPILE
Part No : 80-02-00013
Thermopile volt age vs. blackbody temperature
Type : TP337A
Frequency response
OPTO TECH
Since 1983
Microelectronics Business Division 2003.01 3 / 7
OPTO TECH CORPORATION
Loading...