33.
Specifications
Features
DS10KB-RM
Front Panel
DS10KB-RM
Rear Panel
* DS10KB-RM
* Online double conversion design 
* Pure sine wave output with less than 3% THD 
* Fully digitized microprocessor control 
* Power factor correction 
* Selectable UPS output voltage 
* High efficiency mode 
* Cold start function (DC power on) 
* Emergency power off function (EPO)
DS10KB-RM
* Short circuit and overload protection 
* Fax/Modem/LAN data line surge protection 
* Advanced battery management (ABM) 
* Automatic battery charging in UPS OFF mode 
* Automatic diagnostics and battery check-up 
* Extended battery pack available 
* Multilanguage LCD display 
* RS232 and USB Communication ports, 
 UPS monitoring software
Line Interactive 
UPS Series
On Line UPS
Series
AVR Series
Inverter Series
Surge Series 
Standby UPS
Series
Networking
Series
Green Power
 Series 
windows
2000 / XP
2003 / Vista
Sine Wave
DS10KB-RM 
Topology 
On-battery Output Waveform 
Number of Phase 
INPUT 
Maximum Capacity 
Nominal Input Voltage 
Input Voltage Regulation 
Nominal Input Frequency 
Input PFC 
Input Short Protection 
OUTPUT 
Nominal Output Voltage 
Output Voltage Regulation 
Output T.H.D 
High Efficiency Mode (AC to AC) 
Crest Factor 
Start on Battery 
Auto Restart 
PROTECTION 
Data Line Surge Protection 
BATTERY 
User Replaceable Batteries 
Typical Backup Time (Full / Half load) 
Recharge Time to 90% 
Connected Battery Pack 
ADVANCED WARNINGS / DIAGNOSTICS 
Front Panel LEDs 
Audible Alarms 
COMMUNICATION INTERFACE 
Communication Port 
SNMP Manageable 
ENVIRONMENTAL 
Operation Temperature 
Storage Temperature 
Relative Humidity 
Audible Noise 
PHYSICAL 
Dimensions (Physical / Packing)       (in) 
(LxWxH)                        (mm) 
Weight (Net / Gross)                (lbs) 
                                (kg) 
Battery Pack (Net / Gross)           (kg) 
Battery Pack Dimensions             (in) 
                               (mm)  
CONFORMANCE 
EMI / RFI Compatibility 
Safety Certifications
Model Name
True On-Line, Double Conversion
Pure Sine Wave 
Single Phase (2W+G)
10000VA/7000W
208/220/230/240Vac
176-276Vac
50Hz / 60Hz Auto Sensing 
> 0.97@Full load
Circuit Breaker
208/220/230/240Vac (selectable)
Rated Voltage +/-2%
< 3% T.H.D at Linear Load 
> 92%
3 : 1
Yes 
Yes
RJ11 / RJ45
240V / 12V34W × 20 (in Battery pack)
12/24 min 
<4 Hours
BP10000-RM
AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters
Battery mode / UPS faults / Overload
RS232 and USB Port
Yes
0~40°C / 32~104°F
-20~60°C / -4~140°F
0~95% humidity, non-condensing
<40dBA (at 1 meter from surface of unit)
23.5×16.9×5.1 / 29.1×22×10.7
                                               597×428×130 / 740×560×273                                               
44.1 / 52.9
                                                              20 / 24                                                               
66 / 75.5
23.5×16.9×5.1 / 29.1×22×10.7
                                       597×428×130 / 740×560×273                                       
CE; GOST-R
C-Tick, A-Tick; GOST-R
RS232 
EPO
Input
External 
Battery 
Connector
Communication
Port