OPTI-UPS On Line UPS DS10KB-RM Specifications

33.
Specifications
Features
DS10KB-RM
Front Panel
DS10KB-RM
Rear Panel
* Online double conversion design * Pure sine wave output with less than 3% THD * Fully digitized microprocessor control * Power factor correction * Selectable UPS output voltage * High efficiency mode * Cold start function (DC power on) * Emergency power off function (EPO)
DS10KB-RM
* Short circuit and overload protection * Fax/Modem/LAN data line surge protection * Advanced battery management (ABM) * Automatic battery charging in UPS OFF mode * Automatic diagnostics and battery check-up * Extended battery pack available * Multilanguage LCD display * RS232 and USB Communication ports, UPS monitoring software
Line Interactive
UPS Series
On Line UPS
Series
AVR Series
Inverter Series
Surge Series
Standby UPS
Series
Networking
Series
Green Power
Series
windows
2000 / XP
2003 / Vista
Sine Wave
DS10KB-RM
Topology On-battery Output Waveform Number of Phase INPUT Maximum Capacity Nominal Input Voltage Input Voltage Regulation Nominal Input Frequency Input PFC Input Short Protection OUTPUT Nominal Output Voltage Output Voltage Regulation Output T.H.D High Efficiency Mode (AC to AC) Crest Factor Start on Battery Auto Restart PROTECTION Data Line Surge Protection BATTERY User Replaceable Batteries Typical Backup Time (Full / Half load) Recharge Time to 90% Connected Battery Pack ADVANCED WARNINGS / DIAGNOSTICS Front Panel LEDs Audible Alarms COMMUNICATION INTERFACE Communication Port SNMP Manageable ENVIRONMENTAL Operation Temperature Storage Temperature Relative Humidity Audible Noise PHYSICAL Dimensions (Physical / Packing) (in) (LxWxH) (mm) Weight (Net / Gross) (lbs) (kg) Battery Pack (Net / Gross) (kg) Battery Pack Dimensions (in) (mm) CONFORMANCE EMI / RFI Compatibility Safety Certifications
Model Name
True On-Line, Double Conversion
Pure Sine Wave
Single Phase (2W+G)
10000VA/7000W
208/220/230/240Vac
176-276Vac
50Hz / 60Hz Auto Sensing
0.97@Full load
Circuit Breaker
208/220/230/240Vac (selectable)
Rated Voltage +/-2%
3% T.H.D at Linear Load
92%
3 : 1
Yes Yes
RJ11 / RJ45
240V / 12V34W × 20 (in Battery pack)
12/24 min 4 Hours
BP10000-RM
AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters
Battery mode / UPS faults / Overload
RS232 and USB Port
Yes
0~40°C / 32~104°F
-20~60°C / -4~140°F
0~95% humidity, non-condensing
<40dBA (at 1 meter from surface of unit)
23.5×16.9×5.1 / 29.1×22×10.7
597×428×130 / 740×560×273
44.1 / 52.9
20 / 24
66 / 75.5
23.5×16.9×5.1 / 29.1×22×10.7
597×428×130 / 740×560×273
CE; GOST-R
C-Tick, A-Tick; GOST-R
RS232 EPO
Input
External Battery Connector
Communication
Port