OPTI-UPS Gaming GS1100B Specifications

19.
GS1100B
Gaming Series
GS1100B
* GS1100B
* Powerful Automatic Voltage Regulators * 3 Full Protection UPS Outlets and 3 Surge Protected Outlets * 1050 Joules Surge Energy Rating * Hot Swappable Battery * Extended Battery Life
A fabulous gaming system needs power protection just as much as your new car needs insurance. Blackouts, under voltages, surges and transients are not a concern if you have a decent UPS installed. Protect your very best with OPTI-UPS.
Features
* USB Communication Port * OPTI-SAFE Sentinel software bundled for free * RJ11/RJ45 data line and modem surge protection
Specifications are subject to change without notice.
Win
windows
95/98
ME/NT
windows
2000 / XP
2003 / Vista
GS1100B
Model Name
(in)
(mm)
(lbs)
(kg)
Line-Interactive
Simulated sine wave
1100VA / 550W
110/120Vac or 220/230/240Vac*
50Hz / 60Hz Auto Sensing
Rated Voltage +/- 25%
Circuit Breaker(110V, 120V) ; Fuse (220V, 230V, 240V)
110/120Vac or 220/230/240Vac
Rated Voltage +/- 5% (on battery)
4ms
3 Battery Backup+3 Surge Protection(US)
3 Battery Backup+2 Surge Protection(IEC)
Ye s RJ11 / RJ45 1050 Joules
Full time EMI/RFI filtering
12V / 34W × 1
30~40 min (1PC+1LCD)
<4 Hours
Battery Mode / Battery Fault / Overload
USB
0~40°C / 32~104°F
-20~60°C / -4~140°F <40dBA
12.7x4x6.5 / 16.1x7.7x10.6
332x102x165 / 410x195x268
GS1100B
15.6 / 16.3
7.1 / 7.4
CONFORMANCE Approvals
UL
Topology On-battery Output Waveform INPUT Maximum Capacity Nominal Input Voltage Nominal Input Frequency Input Voltage Range Input Short Protection OUTPUT Nominal Output Voltage Output Voltage Regulation Transfer Time(Typical) Number of Outlets
PROTECTION Automatic Voltage Regulation(AVR) Data Line Surge Protection Surge Energy Rating Normal Mode Noise Suppression BATTERY User Replaceable Batteries Typical Backup Time Recharge Time to 90% ADVANCE WARNINGS Audible Alarms COMMUNICATION INTERFACE Communication Port ENVIRONMENTAL Operation Temperature Storage Temperature Audible Noise PHYSICAL Dimensions (Physical / Packing) (L×W×H) Weight (Net / Gross)
Specifications
Front Panel
Rear Panel
ON/OFF TEST/SILENCE
AC Mode Battery Mode
Battery Fault
Battery Backup Outlets
Input
Surge Protected Outlets
Battery Backup Outlets
Circuit Breaker
Surge Protected Outlets
Input
110V / 120V
220V / 230V / 240V
Simulated Sine Wave
For professional gamers
1PC+1LCD 33 mins
GS1100B
Backup Time (Typical)
Data Line Protection
Communication Port
Data Line Protection
Communication Port
Line Interactive
UPS Series
On Line UPS
Series
AVR Series
Networking
Series
Inverter Series
Surge Series
Green Power
Series
Standby UPS
Series
* See VS1000C on page 6