Series
Standby UPS
Fighter Series
For space concerned and cost sensitive PC users
FS600 / FS600B
FS600 / FS600B
UPS Series
Line Interactive 
Features
* Fully digitized microprocessor control 
* Energy saving function (UPS green mode) 
* 50 / 60 Hz frequency auto sensing and selection 
* Cold start function (DC power on) 
* Short circuit and overload protection 
* Single PCB with reliable design 
* Automatic diagnostics & battery check
Series
On Line UPS
Backup Time (Typical)
  FS600   1PC+1LCD  10 mins 
  FS600B 1PC+1LCD  10 mins
Front Panel
FS600 / FS600B
AVR Series
Rear Panel
FS600
Inverter Series
100V / 110V / 120V
Surge Series 
220V / 230V / 240V
 Series 
Green Power
220V / 230V / 240V 110V / 120V
Series
Networking
FS600B
Power Switch
Battery Mode
UPS Outlet
Convenience 
Outlet
Breaker
AC Input
UPS Outlet
AC Input 
AC Fuse
USB Port
Phone Jack
(In/Out)
Convenience 
Outlet
UPS Outlet
AC Input 
AC Fuse
Breaker
FS600 / FS600B
*
* EMI/RFI noise filter 
* Back up, on-line, battery status, power status display by software** 
* History record of power failure events** 
* Scheduled shutdown & reboot** 
* Smart communication port (USB)** 
* Tel / Modem / LAN surge protection** 
 (**Features of FS-B models only)
.
.
.
.
Specifications
Model Name               FS600                       FS600B
Input
Capacity
Voltage
Frequency 
Inlet
Output 
Voltage* 
(Backup mode) 
Frequency 
(Backup Mode)
Transfer Time 
Receptacles
Protection and filtering
Spike Protection 
Unit Input
Overload 
Protection
10 Base-T Cable Port 
Short Circuit
Battery
Type 
Typical Recharge
Time 
Protection
Typical Backup Time
Alarm
Battery Back-Up 
Battery Low 
Overload
Interface
USB 
Environment 
Ambient Operation 
Audible Noise 
Storage Condition
Physical
Weight ( Net )    kg (lbs)
windows
2000 / XP
2003 / Vista
(mm) 
  (in) 
Dimensions (Physical / Packing )
(L x W x H) 
* See VS1000C on page 6
Simulated sine wave at 100V, 110V, 115V, 120V / 220V, 230V, 240V +/- 5% 
Sealed, maintenance-free lead-acid batteries with 3-6 years typical lifetime 
8.
               600VA / 300W
80-120V (100V), 88-132V (110V)
96-138V (120V), 166-280V (220/230/240V)
50 or 60Hz +/- 10% (auto sensing) 
IEC 320 power inlet 
50 or 60Hz +/- 1Hz 
4 milliseconds (Typical) 
NEMA5-15R or IEC320
Fuse or circuit breaker for overload & short circuit protection 
No
UPS output cut off immediately or input fuse protection 
≒10 min 
Rapid beeping sound (about 1.824Hz) 
No
3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40
2.9 (6.4)
254 x 90 x 126 / 305 x 138 x 191 
10 x 3.5 x 5 / 12 x 5.4 x 7.5
460 Joules, 2ms 
6 hours (to 90% of full capacity)
Auto discharge protection
(PC with 17” LCD monitor)
Slow beeping sound (about 0.47Hz) 
Continuous beeping sound
<40dBA (1 meter from surface) 
15,000 meters max.
3 (6.6)
254 x 97 x 146 / 324 x 146 x 216 
10 x 3.8 x 5.7 / 12.8 x 5.7 x 8.5
Yes
Yes
℃