OptiPure QT10-2, QT-1, QT-2, QT-3 Maintenance Manual

Allow a minimum of 3” under the housing to allow for sump removal and  lter replacement.
would be adversely affected by water.
Your new OptiPure QT-Series FoodService Filtration System will cleanse and condition the tap water providing
125 psi/8.6 bar
100°F/38°C, Min.: 35°F/2°C
3/8” fnpt
Change filters at gallon rating or at least every 6 months, or when pressure gauge needle enters the red
install system on line pressure above 125 psi.
install the system backwards with the feed water line connected to the outlet.
use liquid pipe compounds for  tting connections. USE two to three wraps of Te on tape.
allow system to freeze. Turn off water supply to housing and drain housing if temperature falls below 33°F.
install system in direct sunlight or where system is exposed to harsh chemicals or may be subjected to
water hammer is evident, install water hammer arrestors before OptiPure unit.
Anchor the OptiPure System on a wall stud or suitable mounting material spanning wall studs.
when connecting the feed water line.