 Model: OP350/50
Foodservice Filtration Systems
 Part #: 164-14375
ITEM #: __________________ QTY: ________
Snapshot
The OptiPure® OP350/50 Water Treatment System utilizes 
reverse osmosis (RO) to remove >97% of the total dissolved 
solids (TDS) from water. Then a balance of minerals is 
dissolved into the RO water to provide desirable “Optimized” 
water TDS. The system operates at line pressure and can 
produce up to 350 gallons per day of optimal quality water 
for applications where TDS reduction or the removal of the 
majority of hardness minerals is required. The OP350/50 
is a complete system that includes integrated pre-filtration 
with particulate and chlorine reduction, reverse osmosis 
and mineral addition in a space saving, wall-mount or 
undercounter design. Adjustable Reject Flow Control 
allows precise adjustment of Product/Reject Ratio. A builtin full system bypass valve and sample port assures no 
service interruption and simplifies routine maintenance. 
Also included is a 50 gallon atmospheric storage tank with 
a top-mounted variable-flow repressurization system and a 
sub-micron air breather. Hose, tubing and fittings required 
for installation are included.
System Benefits
JOB NAME/NUMBER_____________________
• Virtually eliminates scale & corrosion problems related to 
high TDS & water hardness and reduce the potential for 
corrosion related to water chemistry.
• 
The integrated QTMA mineral addition cartridge adds 
desirable TDS to provide balanced, buffered Optimized 
water.
• 
High capacity parallel pre-filtration protects the RO 
membrane and assures consistent performance for up to 
one year between pre-filter replacements.
• Compact, Modular Design enables installation under 
counters and in very tight spaces.
• Maximize equipment operating and energy efficiency.
• Adjustable Reject Flow Control minimizes water use due 
to seasonal fluctuations in water temperature.
• Dual-read digital TDS meter provides push-button 
monitoring of membrane performance and optimized water 
quality.
• 
Sample Port allows quick and simple system checks and 
adjustments. 
• 
Built-in pressure gauge allows visual monitoring of 
operating pressure.
• Integrated system bypass valve eliminates down-time or 
service interruptions.
•
All consumables are easy-to-change Qwik-Twist 
cartridges.
• Simple, easy-to-service and maintain design.
Application
Any foodservice equipment where it is desirable to 
remove existing TDS (total dissolved solids) and 
provide a consistent balance of buffered TDS to 
minimize problems associated with high TDS, high 
hardness, high chlorides or any other TDS-related 
problems.
Installation Tips
Feed-water connection to system should be COLD only. 
Do not exceed system specifications for temperature 
  and pressure.
Provide a dedicated 1/2” water line to the unit for   
  consistent flow and pressure to the system.
Allow 3” clearance below system for filter cartridge  
  removal and replacement.
Connect filtered water line to steam production   
  connections only. Do not use for condenser water.
Detailed installation, operation & maintenance manual 
  is included with each system.
 Mount the OP350/50 where it can be easily serviced.
 

Foodservice Filtration Systems
Reverse Osmosis
Processor
 Model: OP350/50
 Part #:  164-14375
Specifications
System 
Dimensions
RO Processor
Repressurization/StorageTank
Connection - Feedwater 3/8” Push Fit Tubing
Operating Pressure Range 60-85 psi at 0.5 gpm
Inlet Water Temperature Range 40o -100
Shipping Weight 25 lbs.
Drain Connection (Within 5’ of unit)
Performance
Typical TDS* Rejection 97+%
 Product Water Production (at 
77ºF, 60psi)
Production rate is strictly dependent on feed 
water temperature and pressure.
Typical Optimized Water TDS 40-80 ppm
25.4”h x20”w x8.4”d
51.5”h x 26.5” dia.
(3.5 -5.9 bar)
o
 F 
o
(4o -38
 C)
2 GPM Minimum Flow
350 gals/day
14.6 gals/hr
0.25 gpm
Dealer/Distributor Info:
Repressurization/Storage 
Tank Assembly
Note: Repressurization Pump/ 
Buffer Tank Stand Assembly 
can be removed from top of 
tank and placed on floor or 
shelf in close proximity of the 
tank. Use Remote Kit PN: 
164-89150.
Feed-Water Chemistry
Feed TDS Up to 1200 ppm
Feed pH 6-10
Hardness* 12 grains or less
Free Chlorine <2 mg/l
Iron 0.1 mg/l max
Turbidity 0.05 NTU
Manganese 0.05 mg/l max
Hydrogen Sulfide 0.0 mg/l
*For water outside of these parameters call OptiPure technical service.
Replacement Media
Description Part Number Qty
CTO-Q Pre-Filters 300-05830 2
AMS-QT Membrane 204-53040 1
MA-Q15 Post-Treatment 300-05855 1
It is recommended that Pre-Filters and Mineral Addition 
Cartridge be changed every 6 months, when capacity 
is reached or when feedwater pressure or flow becomes 
inadequate. Membrane life varies depending on feedwater 
conditions and PreFilter maintenance. 12-18 months under 
typical conditions but it can be as long as 3-5 years.
Options
Description Part Number
QTPT-1 CTO Post-Treatment 160-52120
BPS-QT Booster Pump 164-85020
FXPT-11CR Chloramine Reduction System 160-50011
PRV- Pressure Reducing Valve 164-89938
This product is for commercial use only and must be installed 
maintained according to manufacturers guidelines.
Do not use on water that is microbiologically unsafe or of unknown 
quality without adequate disinfection before or after the system.
 and 
Mfg. by OptiPure div. of Procam Controls, Inc.
2605 Technology Dr., Bldg 300 Plano, TX 75074
p: 972.881.9797; f: 972.422.6262 
e: info@optipure.net  www.optipurewater.com
Warranty
Systems have a 1 year warranty against defects in material and 
workmanship. Warranty does not include filters or membranes. For 
complete warranty information contact OptiPure customer service or 
go to the OptiPure website.
OP350_50specRev2