Snapshot
The OptiPure® OP350/16 Water Treatment System utilizes reverse osmosis (RO) to remove >97% of the total dissolved solids (TDS) from water. Then a balance of minerals is dissolved into the RO water to provide desirable “Optimized” water TDS. The system operates at line pressure and can produce up to 350 gallons per day of optimal quality water for applications where TDS reduction or the removal of the majority of hardness minerals is required. The OP350/16 is a complete system that includes integrated pre-filtration with particulate and chlorine reduction, reverse osmosis and mineral addition in a space saving, wall-mount or undercounter design. Adjustable Reject Flow Control allows precise adjustment of Product/Reject ratio. A built­in full system bypass valve and sample port assures no service interruption and simplifies routine maintenance. Also included is a 16 gallon atmospheric storage tank with a top-mounted variable-flow repressurization system and a sub-micron air breather. Hose, tubing and fittings required for installation are included.
System Benefits
JOB NAME/NUMBER_____________________
Virtually eliminates scale & corrosion problems related to
high TDS & water hardness and reduce the potential for corrosion related to water chemistry.
QTMA secondary mineral addition cartridge adds desirable TDS to provide balanced, buffered Optimized water.
High capacity parallel pre-filtration protects the RO membrane and assures consistent performance for up to one year between pre-filter replacements.
Compact, Modular Design enables installation under
counters and in very tight spaces.
Maximize equipment operating and energy efficiency.
Adjustable Reject Flow Control minimizes water use due
to seasonal fluctuations in water temperature.
Dual-read digital TDS meter provides push-button
monitoring of membrane performance and optimized water quality.
Sample Port allows quick and simple system checks and adjustments.
Built-in pressure gauge allows visual monitoring of operating pressure.
Integrated system bypass valve eliminates down-time or
service interruptions.
All consumables are easy-to-change Qwik-Twist cartridges.
Simple, easy-to-service and maintain design.
Application
Any foodservice equipment where it is desirable to remove existing TDS (total dissolved solids) and provide a consistent balance of buffered TDS to minimize problems associated with high TDS, high hardness, high chlorides or any other TDS-related problems.
Installation Tips

Feed-water connection to system should be COLD only.

Do not exceed system specifications for temperature
and pressure.
Provide a dedicated 1/2” water line to the unit for
consistent flow and pressure to the system.
Allow 3” clearance below system for filter cartridge
removal and replacement.

Connect filtered water line to steam production
connections only. Do not use for condenser water.

Detailed installation, operation & maintenance manual
is included with each system.
 Mount the OP350/16 where it can be easily serviced.
Foodservice Filtration Systems
Reverse Osmosis
Processor
Repressurization/Storage
Tank Assembly
Model: OP350/16
Part #: 164-14416
Specifications
System
Dimensions
RO Processor
Repressurization/StorageTank
25.4”h x20”w x8.4”d
27.3”h x16.1”w x20.6”
Connection - Feedwater 3/8” Push Fit Tubing
Operating Pressure Range 60-85 psi at 0.5 gpm
(3.5 -5.9 bar)
(4o -38
o
F
o
C)
Inlet Water Temperature Range 40o -100
Shipping Weight 25 lbs.
Drain Connection (Within 5’ of unit)
2 GPM Minimum Flow
Performance
Typical TDS* Rejection 97+%
Product Water Production (at
77ºF, 60psi)
Production rate is strictly dependent on feed
water temperature and pressure.
Typical Optimized Water TDS 40-80 ppm
350 gals/day
14.6 gals/hr
0.25 gpm
Replacement Media
Description Part Number Qty
CTO-Q Pre-Filters 300-05830 2
AMS-QT Membrane 204-53040 1
MA-Q15 Post-Treatment 300-05855 1
It is recommended that Pre-Filters & Mineral Addition cartridge be changed every 6 months, when capacity is reached or when feedwater pressure or flow becomes inadequate. Membrane life varies depending on feedwater conditions and PreFilter maintenance. 12-18 months under typical conditions but it can be as long as 3-5 years.
Note: Repressurization Pump/ Buffer Tank Stand Assembly can be removed from top of tank and placed on floor or shelf in close proximity of the tank. Use Remote Kit PN: 164-89116.
Dealer/Distributor Info:
Mfg. by OptiPure div. of Procam Controls, Inc.
e: info@optipure.net www.optipurewater.com
Feed-Water Chemistry
Feed TDS Up to 1200 ppm
Feed pH 6-10
Hardness* 12 grains or less
Free Chlorine <2 mg/l
Iron 0.1 mg/l max
Turbidity 0.05 NTU
Manganese 0.05 mg/l max
Hydrogen Sulfide 0.0 mg/l
*For water outside of these param­eters call OptiPure technical service.
2605 Technology Dr., Bldg 300 Plano, TX 75074
p: 972.881.9797; f: 972.422.6262
Options
Description Part Number
QTPT-1 CTO Post-Treatment* 160-52120
BPS-QT Booster Pump 164-85020
FXPT-11CR Chloramine Reduction System 160-50011
PRV- Pressure Reducing Valve 164-89938
This product is for commercial use only and must be installed maintained according to manufacturers guidelines.
Do not use on water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
and
Warranty
Systems have a 1 year warranty against defects in material and workmanship. Warranty does not include filters or membranes. For complete warranty information contact OptiPure customer service or go to the OptiPure website.