The OptiPure® OP350/16 Water Treatment System utilizes
reverse osmosis (RO) to remove >97% of the total dissolved
solids (TDS) from water. Then a balance of minerals is
dissolved into the RO water to provide desirable “Optimized”
water TDS. The system operates at line pressure and can
produce up to 350 gallons per day of optimal quality water
for applications where TDS reduction or the removal of the
majority of hardness minerals is required. The OP350/16
is a complete system that includes integrated pre-filtration
with particulate and chlorine reduction, reverse osmosis
and mineral addition in a space saving, wall-mount or
undercounter design. Adjustable Reject Flow Control
allows precise adjustment of Product/Reject ratio. A builtin full system bypass valve and sample port assures no
service interruption and simplifies routine maintenance.
Also included is a 16 gallon atmospheric storage tank with
a top-mounted variable-flow repressurization system and a
sub-micron air breather. Hose, tubing and fittings required
for installation are included.
System Benefits
JOB NAME/NUMBER_____________________
• Virtually eliminates scale & corrosion problems related to
high TDS & water hardness and reduce the potential for
corrosion related to water chemistry.
•
QTMA secondary mineral addition cartridge adds
desirable TDS to provide balanced, buffered Optimized
water.
•
High capacity parallel pre-filtration protects the RO
membrane and assures consistent performance for up to
one year between pre-filter replacements.
• Compact, Modular Design enables installation under
counters and in very tight spaces.
• Maximize equipment operating and energy efficiency.
• Adjustable Reject Flow Control minimizes water use due
to seasonal fluctuations in water temperature.
• Dual-read digital TDS meter provides push-button
monitoring of membrane performance and optimized water
quality.
•
Sample Port allows quick and simple system checks and
adjustments.
•
Built-in pressure gauge allows visual monitoring of
operating pressure.
• Integrated system bypass valve eliminates down-time or
service interruptions.
•
All consumables are easy-to-change Qwik-Twist
cartridges.
• Simple, easy-to-service and maintain design.
Application
Any foodservice equipment where it is desirable to
remove existing TDS (total dissolved solids) and
provide a consistent balance of buffered TDS to
minimize problems associated with high TDS, high
hardness, high chlorides or any other TDS-related
problems.
Installation Tips
Feed-water connection to system should be COLD only.
Do not exceed system specifications for temperature
and pressure.
Provide a dedicated 1/2” water line to the unit for
consistent flow and pressure to the system.
Allow 3” clearance below system for filter cartridge
removal and replacement.
Connect filtered water line to steam production
connections only. Do not use for condenser water.
Detailed installation, operation & maintenance manual
is included with each system.
Mount the OP350/16 where it can be easily serviced.
![](/html/e6/e63b/e63bdef9623fd863cf947bdddddefc1739b8054afdc3c5e8b4f37e9d299f0fee/bg2.png)
Foodservice Filtration Systems
Reverse Osmosis
Processor
Repressurization/Storage
Tank Assembly
Model: OP350/16
Part #: 164-14416
Specifications
System
Dimensions
RO Processor
Repressurization/StorageTank
25.4”h x20”w x8.4”d
27.3”h x16.1”w x20.6”
Connection - Feedwater 3/8” Push Fit Tubing
Operating Pressure Range 60-85 psi at 0.5 gpm
(3.5 -5.9 bar)
(4o -38
o
F
o
C)
Inlet Water Temperature Range 40o -100
Shipping Weight 25 lbs.
Drain Connection (Within 5’ of unit)
2 GPM Minimum Flow
Performance
Typical TDS* Rejection 97+%
Product Water Production (at
77ºF, 60psi)
Production rate is strictly dependent on feed
water temperature and pressure.
Typical Optimized Water TDS 40-80 ppm
350 gals/day
14.6 gals/hr
0.25 gpm
Replacement Media
Description Part Number Qty
CTO-Q Pre-Filters 300-05830 2
AMS-QT Membrane 204-53040 1
MA-Q15 Post-Treatment 300-05855 1
It is recommended that Pre-Filters & Mineral Addition
cartridge be changed every 6 months, when capacity is
reached or when feedwater pressure or flow becomes
inadequate. Membrane life varies depending on feedwater
conditions and PreFilter maintenance. 12-18 months under
typical conditions but it can be as long as 3-5 years.
Note: Repressurization Pump/
Buffer Tank Stand Assembly
can be removed from top of
tank and placed on floor or
shelf in close proximity of the
tank. Use Remote Kit PN:
164-89116.
Dealer/Distributor Info:
Mfg. by OptiPure div. of Procam Controls, Inc.
e: info@optipure.net www.optipurewater.com
Feed-Water Chemistry
Feed TDS Up to 1200 ppm
Feed pH 6-10
Hardness* 12 grains or less
Free Chlorine <2 mg/l
Iron 0.1 mg/l max
Turbidity 0.05 NTU
Manganese 0.05 mg/l max
Hydrogen Sulfide 0.0 mg/l
*For water outside of these parameters call OptiPure technical service.
2605 Technology Dr., Bldg 300 Plano, TX 75074
p: 972.881.9797; f: 972.422.6262
Options
Description Part Number
QTPT-1 CTO Post-Treatment* 160-52120
BPS-QT Booster Pump 164-85020
FXPT-11CR Chloramine Reduction System 160-50011
PRV- Pressure Reducing Valve 164-89938
This product is for commercial use only and must be installed
maintained according to manufacturers guidelines.
Do not use on water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
and
Warranty
Systems have a 1 year warranty against defects in material and
workmanship. Warranty does not include filters or membranes. For
complete warranty information contact OptiPure customer service or
go to the OptiPure website.
OP350_16specRev2