Foodservice Filtration Systems
Model: OP1200/50
Part #: 164-15250
ITEM #: __________________ QTY: ________
Snapshot
The OptiPure® OP1200/50 Water Treatment System
utilizes reverse osmosis (RO) to remove >97% of the total
dissolved solids (TDS) from water. Then a balance of
minerals is dissolved into the RO water to provide desirable
“Optimized” water TDS. The system is pump driven and
will produce up to 1200 gallons per day of optimal quality
water for applications where TDS reduction or the removal
of undersirable minerals is required. The OP1200/50 is
a complete system that includes integrated pre-filtration
with particulate and chlorine reduction, reverse osmosis
and mineral addition in a space saving, wall-mount design.
Adjustable Reject Flow Control allows precise adjustment
of Product/Reject Ratio. A built-in full system bypass
valve and sample port assures no service interruption and
simplifies routine maintenance. Also included is a 50 gallon
atmospheric storage tank with a top-mounted variable-flow
repressurization system and a sub-micron air breather.
Hose, tubing and fittings required for installation are
included.
System Benefits
JOB NAME/NUMBER_____________________
• Virtually eliminates scale & corrosion problems related to
high TDS & water hardness and reduces the potential for
corrosion related to water chemistry.
•
The Mineral Addition system adds desirable TDS to
provide balanced, buffered Optimized water.
•
High capacity/High Flow pre-filtration protects the RO
membrane and assures consistent performance for up to
six months between pre-filter replacements.
• Microprocessor Controller provides system status and
pump time-delay on start-up.
• Proven Reliable Rotary Vane Pressure Pump assures
consistent production.
• Membrane Feed Recirculation maximizes membrane life.
• Adjustable Reject Flow Control minimizes water use due
to seasonal fluctuations in water temperature.
• Dual-read digital TDS meter provides push-button
monitoring of membrane performance and optimized water
quality.
•
Sample Port allows quick and simple system checks and
adjustments.
•
Built-in pressure gauge allows visual monitoring of
operating pressure.
• Integrated system bypass valve eliminates down-time or
service interruptions.
•
All consumables are easy-to-change Qwik-Twist
cartridges.
• Simple, easy-to-operate and maintain design.
Application
Any foodservice equipment where it is desirable to
remove existing TDS (total dissolved solids) and
provide a consistent balance of buffered TDS to
minimize problems associated with high TDS, high
hardness, high chlorides or any other TDS-related
problems.
Installation Tips
Feed-water connection to system should be COLD only.
Do not exceed system specifications for temperature
and pressure.
Provide a dedicated 1/2” water line to the unit for
consistent flow and pressure to the system.
Allow 3” clearance below system for filter cartridge
removal and replacement.
Connect filtered water line to steam production
connections only. Do not use for condenser water.
Detailed installation, operation & maintenance manual
is included with each system.
Mount the OP1200/50 where it can be easily serviced.

Foodservice Filtration Systems
Model: OP1200/50
Part #: 164-15250
Specifications
System
Dimensions
RO Processor
Repressurization/StorageTank
Connection - Feedwater 1/2” Push Fit Tubing
Feed-Water Pressure Range 30-90 psi at 2.5 gpm
Inlet Water Temperature Range 40o -100
Shipping Weight 100 lbs.
Drain Connection (Within 5’ of unit)
Performance
Typical TDS* Rejection 97+%
Product Water Production (at
77ºF, 60psi)
Production rate is strictly dependent on feed
water temperature and pressure.
Typical Optimized Water TDS 40-80 ppm
34”h x30”w x8.5”d
51.5”h x 26.5” dia.
(3.5 -5.9 bar)
o
F
o
(4o -38
C)
5 GPM Minimum Flow
1200 gals/day
50 gals/hr
0.833 gpm
Dealer/Distributor Info:
Repressurization/Storage
Tank Assembly
Note: Repressurization Pump/
Buffer Tank Stand Assembly
can be removed from top of
tank and placed on floor or
shelf in close proximity of the
tank. Use Remote Kit PN:
164-89150.
Feed-Water Chemistry
Feed TDS Up to 1200 ppm
Feed pH 6-10
Hardness* 12 grains or less
Free Chlorine <2 mg/l
Iron 0.1 mg/l max
Turbidity 0.05 NTU
Manganese 0.05 mg/l max
Hydrogen Sulfide 0.0 mg/l
*For water outside of these parameters call OptiPure technical service.
Replacement Media
Description Part Number Qty
CTO-Q Pre-Filters 300-05830 3
AMS-QT Membrane 204-44021 1
MA-Q15 Post-Treatment 300-05855 1
It is recommended that Pre-Filters and Mineral Addition
Cartridge be changed every 6 months, when capacity
is reached or when feedwater pressure or flow becomes
inadequate. Membrane life varies from 24-60+months
depending on feedwater conditions and PreFilter
maintenance.
Options
Description Part Number
QTPT-1 CTO Post-Treatment 160-52120
FX-11CR Chloramine Reduction System 160-50011
This product is for commercial use only and must be installed
maintained according to manufacturers guidelines.
Do not use on water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
and
Mfg. by OptiPure div. of Procam Controls, Inc.
2605 Technology Dr., Bldg 300 Plano, TX 75074
p: 972.881.9797; f: 972.422.6262
e: info@optipure.net www.optipurewater.com
Warranty
Systems have a 1 year warranty against defects in material and
workmanship. Warranty does not include filters or membranes. For
complete warranty information contact OptiPure customer service or
go to the OptiPure website.
OP1200_50specRev0