OptiPure FXI-22P User Manual

Model FXI-22P
Performance Data Sheet
Item# 160-50120
The OptiPure FXI-22P water treatment system is Tested and Certi ed by NSF International.
Functional Data
The contaminant reduction capabilities of the system’s combined water treatment technologies offer a wide range of bene ts that include:
Filters out dirt, sediment, rust and other particulate matter.
Takes out disinfectant chlorine and the taste and odor associated with chlorine.
Inhibits corrosion and the formation of scale (lime-scale/calcium carbonate).
Rated Capacity/Service Life: 60,000 gallons (227,100 liters)
Service Flow Rate: 6 gpm (22.7 lpm)
NSF/ANSI Certi ed Performance
This system has been tested according to NSF/ANSI 42 for reduction of the substances listed below. The concentration of the indicated substances in water than or equal to the permissible limit for water leaving the system, as speci ed in NSF/ANSI 42.
Average
Reduction Analysis
Chlorine 1.9 mg/l 0.06 mg/l 50% 96.8%
Taste & Odor
Particulate 0.5 to <1 um 3633333 244000 85% 93.2%
Challenge
entering the system was reduced to a concentration less
Average
Ef uent
Reduction
Requirement
Percent
Reduction
NOTE: Testing was performed under standard laboratory conditions, actual performance may vary. It is recommended that you have your water supply tested to determine your actual water treatment requirements.
NSF’s Certification Program is accredited by the American National Standards Institute (ANSI) and Standards Council of Canada (SCC) for the reduction of claims specified in this Performance Data Sheet.
Replacement Cartridge(s):
Quantitiy Cartridge Item #
2 CTOS-20 252-20220
System Tested and Certi ed by
NSF International against NSF / ANSI
Standard 42 for the reduction of:
Standard 42: AESTHETIC EFFECTS
Chlorine Reduction:
Capacity - 60,000 gallons (227,100 liters)
Taste and Odor Reduction
Particulate Reduction: Class I
Manufactured by FilterXpress div. of Procam Controls Inc. 2605 Technology Dr. Bldg. 300, Plano, TX 75074
(972) 881-9797 Fax (972) 422-6262 www. lterxpress.com
OptiPure Model FXI-22P – Performance Data Sheet
General Installation Requirements
System Dimensions: 26.5” H x 12.5” W x 9.75” D (add a minimum 3” to height to allow for lter sump removal and cartridge replacement). Shipping weight is 24 lbs.
System includes inlet shut-off valve / inlet & outlet are ” NPTF (female).
System feed must be cold water only.
Flush the system for 2 minutes to allow air and any carbon nes to escape. NO ACTIVATION PROCESS OR EXTENDED FLUSHING IS REQUIRED FOR OPTIPURE SYSTEMS TO PERFORM AS CERTIFIED.
Check operating requirements of equipment serviced before shutting off water supply.
System operating range: Pressure: 10-125 psi (0.7-8.6 bar) Temperature: 10-100°F (2 – 38°C)
This product is for commercial use only and must be installed and maintained according to manufacturers
guidelines.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
General Operation & Maintenance Requirements
System will deliver measurable performance for up to six months between lter changes when installed according to application guidelines. Change lters every six months, when capacity is reached or when efuent ow becomes inadequate.
Replacement lter perfromance is assured without activation or extended ushing.
Check operating requirements of equipment serviced before shutting off water supply.
Installation and operation & maintenance manuals are provided with the system and include parts and service availability.
Warranty Information
OptiPure systems carry a three year limited warranty for defects in materials and workmanship when installed and maintained in accordance with manufacturers recommended procedures and guidelines. For complete warrany information refer to the warranty statement included with each system or contact FilterXpress.
NOTE: The FXI-22P utilizes IsoNet (patent pending) to provide protection against corrosion and the
formation & build-up of calcium (lime-scale) on equipment surfaces. Scale and corrosion inhibition is not tested and certied by NSF.
PDS03-FXI22P