Optimum OP-SBWF01 Installation Instructions Manual

WiFi Socket Box
Time Switch
For general purpose use
Installation instructions
OP-SBWF01 WiFI Socket Box Timer
Min switching 1 Minute
1. Installation procedure
2. Backplate wiring Example
3. Backplate wiring Example
(Volt Free)
4. Specification
3,
Backplate wiring: Example (Volt Free)
Wiring diagram (Volt Free)
M
~
12345
5 4 3 2 1 E
LN
Live out to
appliance
230V AC
mains supply
Live In to
timer
To appliance
230V AC Supply
OP-SBWF01 Installation InstructionsOP-SBWF01 Installation Instructions
Power / Set-up
Button
WiFi Signal
Indicator
Specification
Class II control / Protection class IP20
Complies with European Norm
EN 61058-1:2002+A2:2008 Switches for Appliances: General Requirements,and European Directives:
LVD; EMC; RoHS; RED
www.tfc-group.co.uk
TFC Group LLP Tonbridge TN9 1TB
WiFi ISM 2.4GHz; WLAN 802.11 b/g/n 20 On/Off Programmes Countdown On or Off Output switches randomly during set period.
A repeating cycle that can be set between the ON and OFF times.
92 x 92 x 60 170g 1vA @ 230V 50Hz 16 Amperes 4 Amperes (cos Ø 0.6)
-10T55 Internet Synchronised 1 Minute On / Timed / Off
COMMS:
PROG CAPACITY:
COUNTDOWN:
RANDOM:
REPEAT:
DIMENSIONS:
WEIGHT:
POWER:
RESISTIVE LOAD:
INDUCTIVE LOAD:
TEMP RATING:
ACCURACY:
MIN. SWITCHING:
OVERRIDE:
screws, in accordance with circuit diagram label beneath terminals.
Note: Do not connect unprepared
stranded wires. Use ferrules supplied to crimp stranded wire terminations.
3. Fix backplate to socket box.
4. Connect wiring in accordance with wiring diagram.
5. Fit cover over module and reassemble to backplate. Ensuring fixed blue wires are stowed neatly without being trapped.
6. Re-fit and tighten two screws.
7. Switch on mains.
2.
The timer should not be mounted on an unearthed metal or metallised surface.
If the timer is to be connected to an appliance that is required to be earthed the supply earthing conductor and the appliance earthing conductor should be terminated together in the earth terminal provided within the timer.
1. Installation procedure
1. Switch the supply off at the mains. Means of disconnection from the supply having at least 3 mm contact separation in all poles must be incorporated in the fixed wiring mains supply.
2. Unscrew the two screws located top right and bottom left of front module cover; remove cover and gently pull module from backplate. Do not put undue stress on, ‘or’ interfere with fixed connecting wires. Bare wires back for 6 mm (1/4 inch) maximum; insert into terminals and secure with the
Please read the instructions fully
before attempting installation.
IMPORTANT
Installation must be carried out in
accordance with the current edition of
the I.E.E. Wiring Regulations. It is
recommended that installation is
undertaken only by a qualified
electrician.
Timer must not be mounted on a flammable surface.
Ensure that the timer does not come into contact with any combustible materials such as towels or bedding.
Ensure at least a 300 mm air space is allowed around the timer.
OP-SBWF01 Installation Instructions
Backplate wiring: Example (230V AC 50-60Hz)
Wiring diagram (230V AC 50-60Hz)
M
~
12345
5 4 3 2 1 E
L N L N
to appliance mains supply