Optima Home Scales PROFILE, ESSENCE User Manual

version:1.0
OPTIMA HOME SCALES
User Manual
Body Scale
PROFILE
OPTIMA HOME SCALES PO BOX 1526 CUMMING GA 30028, UNITED STATES
TEL:888-688-4833 www.optimahomescales.com
Thank you very much for selecting the OHS Body Scale PROFILE. Please read the user manual carefully and thoroughly to ensure the safe
usage of this product and keep the manual for further reference in case you have problems.
Table of Contents
Safety Information
Safety and Usage Information ........................................................................................................2
Your Scale and Its Environment .....................................................................................................3
Efficient Use of Your Scale .............................................................................................................3
Overview
Device Components .......................................................................................................................4
Function Indication .........................................................................................................................4
List ..................................................................................................................................................4
LCD Display ....................................................................................................................................5
Initial Start-Up
Insert the Battery
Start Measuring
...................................................................................................................
6
Select Measurement Unit ...............................................................................................................7
Initializing Your Scale
.................................................................................................................... 8
Start Measuring
.............................................................................................................................. 8
Troubleshooting
Error Prompt ................................................................................................................................... 9
Specifications ................................................................................................................................... 10
Maintenance ..................................................................................................................................... 11
Warranty............................................................................................................................................ 11
Appendix
EMC Guidance
.............................................................................................................................. 12
1
Table of Contents
Safety and Usage Information
The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury. Please kindly find the meanings of the warning signs and symbols, which you may encounter in the label and user manual, as follows:
Symbol for “THE OPERATION GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Symbol for “DIRECT CURRENT”
Symbol for “ENVIRONMENT
PROTECTION – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local
authority or retailer for recycling advice”
Symbol for “COMPLIES WITH EU REQUIREMENTS”
Symbol for “SERIAL NUMBER”
Your Scale and Its Environment
To ensure your safety as well as the service life of your scale, please avoid using
the scale under the following circumstances:
Slippery floor such as tile floor Jumping onto the platform immediately after bath or with wet feet Near a cell phone or microwave oven
Avoid storage in the following locations:
Where there is water Where the device may be exposed to extreme temperatures, humidity, moisture, direct
sunlight, dust, or salt air Where there is risk of shock or drop Where you store chemicals or full of corrosive gases Where in reach of the infants or children
Efficient Use of Your Scale
To ensure the accuracy of measurement, please follow below instructions when
you start measurement.
Place the scale on a flat, hard surface. Soft surface such as carpet will affect the performance of the scale.
Start measurement at least two hours after Getting up or Dining. Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and
dining. Always start measurement in the same time slot and on the same scale located on the
same flat, hard surface. To ensure the accuracy of weighing, when you move the scale or haven’t used the scale
for a long time, please turn on the scale first, wait until it turns off, then you can stand on the platform again and measure your weight.
When you don’t use the scale, keep it in a safe place. Do not store anything on your scale.
Any information provided by this scale is in no way meant to treat, cure or prevent any disease or illness from happening. If in doubt, contact your physician.
It is intended for use in the domestic setting only.
2
3
Safety Information
Safety Information
Device Components LCD Display
LCD Display
Battery Compartment
UNIT Button
Function Indication
UNIT Button: Press “UNIT Button” to select desired unit in weighing mode.
or
Press “UNIT Button” to turn on the scale.
List
1. Body Scale PROFILE
2. One CR2032 Battery (3V)
3. User Manual
4 5
Overview
Overview
Kilogram
Pound
Insert the Battery
Open the battery door in the back of the scale.
Insert the battery (1 x CR2032) into the battery compartment according to the polarity indications marked inside the compartment.
* All the digits will be shown on the LCD.
Close the battery door and wait until the digits “0.0kg” are shown on the LCD.
Select Measurement Unit
With battery correctly installed, press “UNIT” button in the back of the scale to select
measurement unit. The default measurement unit is “kilogram”. You may press “UNIT”
button to choose among kilogram and stone.
6
7
Initial Start-Up
Start Measuring
CAUTION
When the symbol appears, the device will power off in four seconds. When this happens replace with a new battery. Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries.
Initializing Your Scale
1. Press the platform center and remove your foot or
Press UNIT button to turn on the scale.
2. “0.0” will be displayed.
3. The scale will switch off and is now ready for use.
This initialization process must be repeated if the scale is moved. At all other times step straight on the scale.
Error Prompt
Error
Description
Solution
Overload. The device will
power off.
Stop using this scale for
measurement.
Low Battery. The device will power off in four seconds.
Replace with 1xCR2032 new battery. Please purchase the authorized batteries for replacement.
Start Measuring
1. Place the scale flatly on a hard surface.
2. Step onto the platform and stand still until the numeral on the LCD stops blinking, then the weight is locked.
3. The measuring result is displayed for about 10 seconds, and then it will turn off.
Note: If there is no operation in 10 seconds when the scale is on, it will turn off automatically.
8 9
Start Measuring
Troubleshooting
Specifications
Maintenance
Product Name
PROFILE
Dimension
Scale: 300x300x19mm (Approximately)
Net Weight
Approximately 1.52kg (Excluding the cell)
Display
Digital LCD
Measurement Unit
Kilogram / Stone
Measurement Range
5kg~180kg
Division
0.1kg / 0.2 lb
Accuracy
50kg: ±0.3kg; 100kg: ±0.4kg; 150kg: ±0.5kg;
Working Environment
Temperature: 5to 40Relative Humidity: 90% RH
Atmospheric pressure: 86kPa to 106kPa
Storage Environment
Temperature: -20to 60Relative Humidity: 90% RH
Atmospheric pressure: 50kPa to 106kPa
Power Source
3V (One CR2032 Battery)
Auto-ON
SENSE ON technology
Auto-OFF
The scale will turn off after about 10s if there is no operation.
Accessories
1. One CR2032 Battery
2. User Manual
Mode of Operation
Continuous Operation
About the Accuracy of This Product
This product passes strict inspection before delivery and therefore its accuracy is guaranteed by the manufacturer.
Please refer to the above table for the descriptions on accuracy.
This product is specially designed for body scale as well as weight measurement. It should NOT be used by anyone
during the process of transaction for verification of goods’ weight.
When carrying out usual maintenance, please ensure practice of the following Do’s and
Don’ts:
DO use a dry soft cloth to wipe the dust. DO use a wet soft cloth, dipped into water and wrung out, to wipe the dirt. Then use a
dry soft cloth to dry up the device.
DON’T wash the device with water or immerse it in water.
DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of
discolor or malfunction. DON’T disassemble this device. If you have any problems, please contact OHS.
(Please refer to Warranty for contact information)
Warranty
OHS warrants its products free of defects in materials and workmanship in normal use for a period of TEN years from the date of retail purchase. This warranty does NOT cover damages caused by misuse or abuse, including but not limited to:
Failure caused by unauthorized repairs or modifications; Damage caused by shock or drop during transportation; Failure caused by improper operation inconsistent with the instructions stated in this user manual; Malfunction or damage from failure to provide the recommended maintenance; Damage caused by improper use of power supply.
Should this device require maintenance (or replacement at our option) under warranty, please deliver the original package to OPTIMA HOME SCALES prepaid. Please return the store receipt (with the retail purchase date) and a note with reasons to return on it as well.
10
11
Specifications
Maintenance
OPTIMA HOME SCALES
PO BOX 1526 CUMMING GA 30028 UNITED STATES TEL: 888-688-4833 www.optimahomescales.com
EMC Guidance
1. MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS.
2. Wireless communications equipment such as wireless home network devices, mobile phones, cordless telephones and their base stations, walkie-talkies can affect this equipment and should be kept at least a distance d = 3,3 m away from the equipment. (Note. As indicated in Table 6 of IEC 60601-1-2:2007 for ME EQUIPMENT, a typical cell phone with a maximum output power of 2 W yields d = 3,3 m at an IMMUNITY LEVEL of 3 V/m)
12
Appendix
Loading...