* Control Power Switch of Remote Equipment via network or phone voice to replace the presence of the personnel * LED face board to inspect current equipment ID, Main Current and each Router Current directly * Execute Power On / Off Reboot via console to manage its performance * Detect whether two sets of power circuit are normal automatically * It can be linked with 16 sets monitors at maximum to control up to 128 sets of connected devices * It can be attached temperature detector to control the power switch according to environment change * It is equipped with overloading electric breaking protector to avoid overloading to cause device damage * Support nearby Manual Power Switch * Support Wake on Ring function. ATX equipment can be started normally * Provide 20 sets of accounts and passwords for your own setting to manage different power switches * Record the user’s operating message and abnormal message to provide the user to check the case afterwards * Support Power Start sequence setting to prevent all of switches from starting simultaneously to cause sudden overloading and effect equipment working * Provide API interface. The manager can develop the control software by himself * Support Windows, Linux to execute the safety shutdown and avoid system damage * Pre-set Switch Start Time and arrange the working schedule for power supply * Each rout can detect UPS low power signal to provide safety shutdown management for the equipment * Detect whether the power current of all routes are normal or not to avoid current overloading to damage the device * By brief message and email warning to practice the instant surveillance and warning to important equipment * Provide remote net firmware to renew the function * Provide the function of IP and MAC address filter that prevent unauthorized user from access the device
Smart Power Series - SP2L / SP4L / SP8H / SP8L
Digital Monitor PDU for the cabinet of Datacenter
Features
* The Master or Slave that setup in the cabinet can connect up to 6 unit PDU * The Master/Slave RJ45 socket in the back end can connect 6 PDU * The Master/Slave has 6 button that sign 1-6 separately. It can check all connected PDU’s current. The scan button can show every connected PDU’s current alternately * The Master/Slave build-in the sensor of temperature/humidity and show it on LCD panel. Administrator can learned about temperature/humidity of cabinet from LCD panel * Every Slave can daisy-chain to Master by the RJ11 PORT(UP&DOWN) in the front end. Any of Slave breakdown don’t affect other Slave’s data transmitter, all Slave’s data will bypass to the Master
Central monitor software
Master1......Master8