Optex X-Zone T Quick Setup Manual

Sensor Mounting Location
Sensor Settings
OPTEX X-Zone T Quick Setup Guide
For detailed information, please refer to the installation manual supplied with each sensor and notes please refer to the X-Zone T Connection Matrix.
2”
1/4”
Align with center of clear door opening
Use supplied Mounting Template. Place template so that it is in the center of the clear door opening and so that the bottom of the tem­plate is between 1/4” and 2” from the bottom edge of the header.
Drill (2) 1/8” holes and (1) 5/16” hole as indi­cated on the template. Remove template from header. Remove the cover from the sensor. Fasten the sensor securely to the header using the supplied screws (do not over-torque screws or sensor body may distort).
Remove the cover and unfold the label.
Ensure sensors are properly set to factory defaults as shown and described below.
NOTE: If uni-directional motion detection is desired, move dipswitches 9 UP.
1. Dipswitch settings
Refer to instruction manual for details on all dipswitch settings.
2. AIR Area Width
Set shutters to Wide Position
3. AIR (Presence) and Microwave Angle Adjustments
4. Microwave Sensitivity
5. Walk Test
AIR Angle Adjust
Set Red Ring at –2 degrees
(Arrow at Approx. 10 o’ clock)
Set to 10 o’clock (two dots at top)
Microwave Angle Adjust
Set center Philips adjuster to 38 degrees
(Blue Dots are at 2 o’ clock)
Power up sensors and wait 10 seconds to test presence area. Perform walk test procedure to verify substantial compliance with ANSI A156.10 section 8.
18730 Wilmington Ave, Unit 100 Rancho Dominguez, CA 90220 Ph 310 214-8644 Fax 310 898-1098 Toll free 800 877-6656 www.ot-inc.com
OPTEX Technologies Inc.
8510 McAlpine Park Dr. Suite 108 Charlotte, NC 28211
OPTEX Technical Support (800) 877-6656 East Coast: Perry Watkins, Ext. 220 Central U.S.: Jason Kirn, Ext. 201 Support: Refugio Guadaljara, Ext. 202
WARNING: To comply with ANSI A156.10, if the reveal on the door (mounting surface of sensor to face of sliding panel) is great­er than 2½”, turn the AIR adjuster (Red Ring) CCW (Shallow) until the door recycles on the closing cycle. Then refer to step 2 under troubleshooting to properly adjust the AIR angle.
Troubleshooting
1. Operation LED turns solid Orange then
door reopens (Microwave Motion Detecting
Door)
2. Operation LED turns Flashing Red, then door reopens
(Row 2 Presence Detecting Door)
a. Reduce sensitivity: turn sensitivity po-
tentiometer CCW.
b. Adjust Microwave angle towards deep
(Clockwise) slightly.
a. Move AIR angle adjustment
(Red Ring) slightly Clockwise until
ghosting stops.
NOTE: When changing the AIR angle, sensor may go into detection
and hold door open. In this case, reset sensor by moving any dip-
switch, then move it back.
Door reopens on closing cycle:
Wiring Diagram
Door Controller
Note: For OEM manufacturer
specific connections, refer to the
X-Zone T Connection Matrix.
24 VDC
0 VDC
GND
Interior Activation
GND
Presence 1
+24 VDC
-0 VDC (Test Output/Monitored)
24 VDC
0 VDC
GND
Exterior Activation
GND
Presence 2
Power Supply 1
Activation Output 2
Presence Output 3
Test Input 4
Power Supply 1
Activation Output 2
Presence Output 3
Test Input 4
Gray
Gray
Gray
Gray
White
White
Yellow
Yellow
Yellow/Black
Yellow/Black
White/Black
White/Black
Red (+)
Black(-)
Red (+)
Black(-)
Interior Sensor
Exterior Sensor
Notes:
1. Dipswitch 14 must be set ON (UP) for simultaneous output.
2. With Dipswitch 15 ON (UP) the BLUEZONE (Row 1) will be active.
3. When installing two or more sensors in close proximity to each other, vary the frequency settings for each
sensor (dipswitches 5 & 6).
4. Dipswitch 11 Activation output standby mode relay logic, "N.O. OFF" or "N.C. ON".
5. Dipswitch 12 Safety output standby mode relay logic, "N.O. OFF" or "N.C. ON".
6. Red & Black wires (Test Input) are only used when the control box has monitoring capability.