Calibration
1. Install the pole for the sensor in the following layout configuration. Installation height: 500mm(19.69in.) from the ground to the bottom of the sensor Installation angle: 90 degrees to the vehicle direction of travel.
Vehicle Path
90°
Sensor
Two way traffic lane : Install the sensor on the the lane of traffic you wish to monitor. The sensor cannot detect a vehicle in the opposite lane.
Road not to be detected
Road not to be detected
500mm(19.69in.)
[4] Fix the base using 4 screws.
[6] Attach the sensor body to the base
and adjust the sensor angle.
[5] Connect wires.
Power Output1 Output2
Applicable Wire
Single conductor: 0.5-1.2mm (equivalent to CPEV) Stranded wire: 0.3-2.0sq
Non-Voltage Relay Output N.O./N.C. Switchable 30VDC 0.3A or less (resistance load)
Non-Voltage Relay Output N.O./N.C. Switchable 30VDC 0.3A or less (resistance load)
Power Supply 12-24VDC
3.
Set the Microwave maximum range. Recommended to set the range 1m(3.28ft.) shorter than the actual width of the road.
Maximum Range (m)
Output1
1 2 3 4 5 6 7 8
Output2 N.O. N.C.
N.O. N.C.
Maximum Range Botton
Road to be detected
2. Install the sensor, wire it and apply power.
[1] Make holes to mount the sensor.
5(0.20)
Depending on the
cable diameter
M4 Tap
Mounting
GL+588(23.15)
Pitch 32±1
(1.26±0.04)
[Unit : mm(inch)]
[2] Run a cable thru the post or pole.
Mounting Pitch
70±1(2.76±0.04)
Road to be detected
Hold here and pull forward
[3] Loosen the retaining screws on the bottom
of the front cover and remove the front cover, detach the sensor unit.
4. Perform calibration in order to memorize the
5. System operation check.
background of the detection area. Ensure no pedestrians or vehicles are present.
Standby Area Check Detection Calibration
Calibration Area Check
1. Press the Calibration button.
2. Operation indicator blinks in blue.
3. Step away from sensor and outside detection area.
4. Green LED lights when done correctly.
6. Put the front cover on the top of the base first, and attach it while spreading it open and pushing down the front cover.
Check the entire coverage area by using actual vehicle.
Left side of the lane
Center of the lane
Right side of the lane
Sensor
7. Tighten the front cover retaining screw.