Optex OP-08CBL, OP-08CW Installation

(01.03) 2.2.4 / pag. 1
Before using, read this instruction manual thoroughly for proper installation procedures.
[!] CAUTION
BE CAREFUL NOT TO BE STRUCK BY THE DOOR
This product is a door activating non-contact sensor which is to be mounted to/into the transom of an automatic door or to
the ceiling. Do not use it for other applications.
D etection Area
D etection Method of O P-08C
This product outputs a signal when there is a difference in temperature between the floor surface of the detection area and
an entering person.
Actual D etection: D etection may be difficult in the following cases:
-When the floor temperature has increased to a point where there is little difference between the person and floor surface.
-When someone approaches the door from a direction other than the front.
[!] ATTENTION
* Do not install the OP-08C beyond a distance of 4 m.
The sensor may not be able to detect a human body at distances greater than 4 meters. * Be sure to use a beam switch in combination with the OP-08C to provide a back-up safety device.
Even if there is a person standing near the door, it may start closing. * Affix the accessory area masking seal properly. If it is not affixed properly, sensitivity will be reduced dramatically and an entering person may be struck by the door.
PASSIVE INFRARED SENSOR
PEOPLE FRIENDLY
©
READ FIRST
INSTRUCTION MANUAL
O P-08CW (White)
O P-08CBL (Blac k)
[!] ATTENTION
WATCH OUT FOR THE DOOR
Do not use the OP-08C to detect the objects (push cart, etc.) other than human bodies.
The OP-08C must recognize a temperature change to activate. A push cart may or may not have the required temperature
change to activate the sensor.
N ote: This p roduct d etects only changes in temperature and will not d etect a m otionless object!
SPECIFICATIONS
M odelOP-08C
Mounting Height Within 4.0 m.
Detection Method Passive infrared detection
Current Draw 50 mA Max.(at 24 V DC)
Power Supply 12-24 V AC/DC
Detection area See drawing on page 3.
Output ContactForm C Relay, 24 V DC, w ithin 1 A (Resistance Load)
Power/Operating Indicator
LED ON: Standby
LED OFF: Detection
Relay Hold Time Approx. 1.5s
Operating Temperature -20°C ~ +55°C (-4°F ~ +131°F)
Weight 90g (3.2oz)
Accessories
2 m Connection Cable, 2 Mounting Screws, Mounting Template, Area Masking S eal
Specification subject to change without prior notice.
(01.03) 2.2.4 / pag. 3
BC DEF
2.5(8.2) 0.3(1.0) 1.8(5.9) 3.6(11.8) 0.8(2.6) 2.3(7.5)
A 3.0(9.8) 0.4(1.3) 2.1(6.9) 4.3(14.1) 1.0(3.3) 2.8(9.2)
4.0(13.1) 0.5(1.6) 2.9(9.5)5.7(18.7) 1.3(4.3) 3.7(12.1)
ADJUSTMENT (Turn on the power )
Confirmation of the detection area
This product is made up of the detection area shown in the diagrams
above.
A Mounting Height
B Area Width
C Area Width
D Area Width
E Area Depth
F Area Depth
A Mounting Height
B Area Width
C Area Width
D Area Width
BC DEFG H
2.5(8.2) 0.5(1.6) 1.5(4.9) 2.5(8.2) 1.4(4.6) 3.3(10.8) 3.0(9.8) 5.0(16.4)
A 3.0(9.8)0.6(2.0) 1.8(5.9) 2.9(8.5) 1.6(5.2) 3.9(12.8) 3.7(12.1) 6 .0(19.7)
4.0(13.1) 0.8(2.6) 2.5(8.2) 3.9(12.8) 2.2(7.2) 5 .2(17.1) 4.9(16.1) 8 .1(26.6)
W ide and Deep D etection A rea
Standard D etection A rea
< Caut ion >
This p roduct uses a m ethod of detecting the change in
temperature w hen a person enters the detection area.
A ccording to the background temperature, the detection
s ensitivity may b ecome higher or l ower.
Further, b ecause only changes in temperature are detected,
a person w ho is not moving will not be detected.
Selection of the w ide & Deep detection area and s tandard detection area.
In this product, it is possible to change between the wide & deep d etection area
and standard detection area by inserting the lens. When shipped from the factory, the product is set to the standard detection area.
< To set to the wide & deep detection area>
(1)Remove the panel cover.
(2)
(3)
(4)
the mounting surface side
.
Area Depth
Area Depth
Area Width
Area Width
E
F
G
H
k
n
mar
k
(01.03) 2.2.4 / pag. 2
CONSTRUCTION
(1)
Main body
(2)
Relais inversion switch
(3)
(4)
(5)
(6)
(7)
INSTALLATION
Installing the main body
(1)Affix the mounting template to your desired position on the transom or ceiling
(mounting height within 4.0m).
(2)Drill mounting holes (Ø 3.4 mm) as indicated on the mounting template. If
concealed wiring is preferred, drill a wiring hole (Ø 8 mm.) After drilling holes,
remove the mounting template.
(5)Connect the connector for the main body to that of that wiring cord. To disconnect
them, press both knobs and pull them apart.
< Connecting the Connectors >
Insert the connectors deeply into each other. Otherwise, the OP-08C may malfunction due to a contact failure.
(4)As shown in the left figure, remove the housing cover. Using the accessory
mounting template, affix the main body. Attach the main body to the transom, leaving about 10 mm. of the screws's threads exposed.
Grey: Power source
Grey: Power source
White: COM
Yellow:
Green:
12 to 24 V. AC/DC
4 m
(13,1 ft)
max.
< Precautions for M ounting >
- Do not place swaying objects, such as a potted plant, flag or banner in the
detection area. The sensor may not function properly.
-When using wiring knockout, be sure to install the OP-08C in a location
protected from rain. If exposed to rain, water may enter the housing and
damage the device.
(3)Connect a wiring cord to the door controller.
N ote that the wiring method differs depending on setting of the
r elay inversion switch.
< When the relay inversion switch is "Fail-Safe" >
Install the main body in such a manner that the connector can be connected easily.
Grey: Power source
Grey: Power source
White: COM
Yellow:
Green:
< When the relay inversion switch is "Fail-Secure">
12 to 24 V. AC/DC
N.O.
N.C.
N.O.
N.C.
Sensitivity selector switch
Transom mounting hole
Overhead mounting hole Lens Power/Operation indicator lamp (Green indicator lamp)
re
y
Whit
e
ree
n
Yell
ow
To Door Controller
N.O.
N.C.