Optex OA-FLEXT Specsheet

Active Infrared Door Sensors
FOR SLIDE DOOR
FOR SWING DOOR
OA-FLEX T
Flexibility for More Safety and More Reliability
Whole presence detection capability OA-FLEX T can use detection area as presence detection area and possible to utilize for various applications.
Adapted in Cold District
-31°F to 131°F
Active Infrared
How it Works: When the approach area detects a person or object, the sensor will activate the door and turn on the “BLUEZONE” which detects through the threshold. As long as someone is in
the detection area, the sensor will keep the door in the open position. Once the area is cleared,the “BLUEZONE” will ignore the door panels and allow the door to safely close.
Complied with
New ANSI
standard
Monitoring Capability
OA-FLEX T has built-in “monitoring capability”. The OA-FLEX T monitors all its critical functions and noties compatible controls when an error occurs.
Self monitoring capability ensures a higher level of performance over the life of the sensor.
Detection Area
Door Sensors
Dimensions
)
"
36(1 7/16") 43(1 11/16")
7.5(5/16
)
"
68(2 11/16
OA-FLEX T
245(9 10/16
125(4 15/16
"
)
"
61/7 1(73)
)
"
[mm (inch)]
BLUEZONE
(1st row)
2nd row
3rd row
4th row
5th row
6th row
Specifications
Model
Cover color
Mounting height
Detection area
Detection method
Area angle adjustment
Power supply (*2 )
Power consumption
Operation indicator
Operating humidity
H
I
J
OA-FLEX T
Black
2.0 m (6'7") to 2.5 m (8'2")
See DETECTION AREA
Active infrared reflection(*1)
Depth : -8° to +8°
Width : ±7°
( 2 clicks with 3.5°every click-Left/Right )
12 to 24 VAC ±10% (50 / 60 Hz)
12 to 30 VDC ±10%
< 2.0 W (< 5 VA at AC)
See Operation indicator table
< 80%
A
X
B
C
D
E
F
Test intput
Activation output
Safety output
Operating temperature
Noise level
Output hold time
Response time
IP rate
Weight
: Emitting spots
: Emitting spots (can be eliminated)
: Detection Area
G
Opto coupler
Voltage / 5 to 30 VDC
Current / 6 mA Max. (30 VDC)
Form A relay
50 V 0.3 A Max. (Resistance load)
Form A relay
50 V 0.3 A Max. (Resistance load)
-35 to +55°C (-31 to 131°F)
< 70 dBA
Approx. 0.5 sec.
< 0.3 sec.
IP54
220 g (7.8 oz)
Emitting area
A
2.00 (6'7")
B
0.13 (5")
C
0.38 (1'3")
D
0.71 (2'4")
E
0.84 (2'9")
F
1.34 (4'5')
G
1.75 (5'9")
H
0.92 (3')
I
1.49 (4'11")
J
2.06 (6'9")
[ m (feet,inch) ]
2.30 (
7'7"
) 2.50 (
8'2"
) 3.00 (
9'10"
)
'11"
'10"
0.21 (
8"
)
0.60 (1
'8"
)
'12"
)
1.13 (3
'1"
)
'7"
)
'9"
)
'6"
)
)
'5"
)
)
1.31 (4
2.11 (6
2.75 (9
1.45 (4
2.34 (7
3.23 (10
'11"
'8"
)
'4"
)
)
'
)
'9"
)
'8"
)
'7"
)
0.16 (
0.46 (1
0.86 (2
1.01 (3
1.62 (5
2.11 (6
1.11 (3
1.80 (5
2.48 (8
Charts show the values in the following area angle adjustment settings ; Depth : 0°
Width : 0°
Accessories
*1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence
detection function.
*2 : When using this sensor, the sensor has to be connected to
a door system which has the SELV circuit.
*3 : Overcurrent protection with less than 2A.
'10"
'11"
'11"
0.17 (7")
6"
)
0.50 (1
'6"
)
0.94 (3
)
1.09 (3
'4"
)
1.76 (5
'4"
)
2.29 (7
)
1.20 (3
'8"
)
1.95 (6
)
2.69 (8
'2"
)
1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m(9'10")
(8 × 0.22 mm AWG24 ) (*3 )
Manufacturer / Asia sales Div.
OPTEX CO.,LTD.
5-8-12 Ogoto Otsu Shiga 520-0101 Japan TEL.: +81-77-579-8360 FAX.: +81-77-579-8190
Asia Sales Div.
TEL.: +81-77-579-8030 FAX.: +81-77-579-8136 WEBSITE: www.optex.co.jp/as/eng/index.html
North and South American Subsidiary
OPTEX INCORPORATED.
AMERICAS HEADQUARTERS
18730 South Wilmington Ave. Suite 100 Rancho Dominguez, CA 90220 U.S.A. TOLL-FREE: 800 877 6656 FAX.: +1 310 214 8655 WEBSITE: www.optextechnologies.com
East Coast Office
8510 McAlpines Park Drive, Suite 108 Charlotte, NC 28211 U.S.A. TOLL-FREE: 800 877 6656 FAX.: +1 704 365 0818 WEBSITE: www.optextechnologies.com
European Subsidiary
OPTEX Technologies B.V.
Henricuskade 17, 2497 NB The Hague, The Netherlands TEL.: +31(0)70 419 41 00 FAX.: +31(0)70 317 73 21 E-MAIL: info@optex.eu WEBSITE:
www.optex.eu
Copyright (C) 2016 OPTEX CO., LTD. No.77083-17376-00-1606