Optex OA-FLEX AIR T User Manual

5923780 AUG 2015
MANUFACTURER'S STATEMENT
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise it may cause electric shock or breakdown of the equipment.
Danger of electric shock.
WARNING
NOTE
Disregard of warning may cause the improper operation causing death or serious injury of a person.
Special attention is required to the section of this symbol.
Disregard of caution may cause the improper operation causing injury of a person or damage to objects.
NOTE
Read this operation manual carefully before use to ensure proper operation of this product. Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the changed settings and the date shall be registered in the maintenance logbook accompanying the door.
NOTE
The following conditions are not suitable for sensor installation :
- Fog or exhaust emission around the door.
- Wet floor.
- Moving objects or objects that emit light near the detection field.
- Highly reflecting floor or highly reflecting objects around the door.
- Grating floor.
It is required to check the operation manual if this symbol is shown on the product.
1
CAUTION
Risk of getting caught.
Make sure to affix the mounting template as described in the above chart , otherwise it can be dangerous since there may be no detection area around the threshold. Install the sensor as low as possible on the header.
H : Height from the floor to the bottom of the header Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
(The mounting height is "H + Y".)
Maximum mounting distance (Y)
X
H
Y
Sensor
Door
Header
Floor
X
2.00 (6'7")
2.30 (7'7") 2.50 (8'2")
0
No limit
0.05 (2")
0.20 (8") 0.20 (8")
0.10 (4") 0.20 (8")
0.20 (8") 0.20 (8")
0.15 (6") 0.13 (5")
0.15 (6") 0.19 (7")
0.20 (8")
-
0.12 (5") 0.14 (6")
0.25 (10")
0.30 (12") -
H
0.20 (8")
-
--
- 0.11 (4")
[m (feet,inch)]
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø3.4mm (ø1/8").
3. To pass the cable through the header, drill a wiring hole of ø10mm (ø3/8").
4. Remove the mounting template.
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
NOTE
Make sure not to mount the sensor lower than the bottom of header.
WARNING
Danger of electric shock.
Do not use the sensor without the cover. When using the cable knockout, install the sensor indoors or use the rain-cover (Separately available) otherwise electric shock or breakdown of the sensor may occur.
4
Place the housing cover. If wiring is to be exposed, break the knockout.
2
3
BLUEZONE AREA
When dipswitch 15 is set to "ON", the BLUEZONE area, that provides extra safety over the threshold, is activated. In case the BLUEZONE function is not required, set dipswitch 15 to "OFF". Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.
BLUEZONE (1st row)
2nd row
3rd row
BLUEZONE (1st row)
2nd row
3rd row
INSTALLATION
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches. (See ADJUSTMENTS 4. Dipswitch settings)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON. When turning the power ON or after adjusting the settings, do not enter the detection area for more than 10 seconds in order to enable the presence detection.
OA-FLEX AIR T
OUTER DIMENSIONS AND PART NAMES
(1) Connector (2) Mounting holes (3) Operation indicator (4) Function switch
(8) Area angle adjustment screws (9) Area width adjustment screws
(5) FLEX EYE Width angle adjustment screw (6) FLEX EYE Depth angle adjustment screw (7) Dipswitches
(10) Detection window (11) Area adjustment tool
Touchless plate
245(9 10/16") 37(1 7/16")
7.5(5/16
"
)
68(2 11/16
"
)
36(1 7/16") 43(1 11/16")
125(4 15/16")
(1) (2)
(3) (9)(8)(5) (6) (7) (10)
(11)
(4)
This sensor is designed to detect a hand approaching to a touchless plate as a knowing act activation device. Please make sure to understand the following working principle. If FLEX EYE mode is enabled (Dipswitch 14 is set to "ON"), this sensor an activation output when both FLEX EYE and 2nd to 4th row of detection area detect some objects. FLEX EYE means an area for the hand detection.
Safety output is designed to be used on door system that enables only while the door is open. When FLEX EYE is enabled (Dipswitch 14 is set to "ON"), detection area (of 2nd to 6th row) is
safety output area.
BLUEZONE is only activated while Activation output is emitted. When no detection, BLUEZONE is deactivated.
123456123456
FLEX EYE
123456
WORKING PRINCIPLE
Model Cover color Mounting height Detection area Detection method
FLEX EYE angle adjustment
Power supply (*2) Power consumption
Operation indicator
Activation output
: OA-FLEX AIR T : Silver / Black : 2.0m(6'7") to 2.5m(8'2") : See DETECTION AREA : Active infrared reflection(*1)
: Depth : -14° to +2° Width : ±42° (7 clicks with 6°every click-Left/Right)
: < 2.5W (< 6VA at AC) : See Operation indicator table
Output hold time
Operating temperature Operating humidity
IP rate
Weight Accessories
: Approx. 0.5 sec.
Noise level : < 70dBA Response time : < 0.3 sec.
: -20 to +55°C (-4 to 131°F) : < 80%
: IP54
: 230g (8.1oz) : 1 Operation manual 2 Mounting screws 1 Mounting template
The specifications herein are subject to change without prior notice due to improvements.
NOTE
*1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function. *2 : When using this sensor, the sensor has to be connected to a door system which has the SELV circuit. *3 : Overcurrent protection with less than 2A.
*4 : See BLUEZONE AREA
SPECIFICATIONS
1 Area adjustment tool 1 Cable 3m(9'10")
Area angle adjustment
Width : ±7° (2 clicks with 3.5°every click-Left/Right)
: Depth : -8° to +8°
: Form A relay 50V 0.3A Max. (Resistance load)
Safety output
: Opto coupler (NPN) Voltage / 5 to 50VDC Current / 100mA Max. (Resistance load) Dark current / 600nA Max.
Safety intput : Opto coupler
Voltage / 5 to 30VDC Current / 6mA Max. (30VDC)
: 12 to 24VAC ±10% (50 / 60Hz) 12 to 30VDC ±10%
Operation indicator table
1sec. 1sec.
Status
Stand-by (Operation mode)
Set-up
BLUEZONE (1st row) detection (*4)
2nd row detection 3rd row detection
4th-6th row detection
Operation indicator color
Yellow Blinking
Green
Blue
Red Blinking
Red
Orange
Signal saturation
Signal saturation (FLEX EYE)
Sensor failure
Slow Green Blinking Slow Purple Blinking Fast Green Blinking
Setting error Red & Green Blinking
Stand-by (Installation mode) Yellow
FLEX EYE detection
FLEX EYE & 2nd-4th row detection
Fast Purple Blinking
Purple
Category Performance level
: 2 (EN ISO 13849-1 : 2008/AC:2009) : d (EN ISO 13849-1 : 2008/AC:2009)
ESPE : Type2
(8 × 0.22mm² AWG24) (*3)
ENGLISH
NI-0066-0
Original instructions
To the connector of the sensor
Power supply
12 to 24VAC±10% /12 to 30VDC±10%
}
1.White
2.Brown
3.Green
4.Yellow
5.Pink (+)
6.Blue (-)
7.Red (+)
8.Black (-)
Safety output
Opto coupler(NPN) / Voltage: 5 to 50VDC
Activation output
Form A relay 50V 0.3A Max.
Safety input
Opto coupler / Voltage: 5 to 30VDC
Before starting the procedure, make sure that the power is turned OFF. When passing the cable through the hole, do not tear the shield. otherwise it may cause electric shock or breakdown of the sensor.
WARNING
Danger of electric shock.
COMPLIED STANDARDS AND EXTRACT FROM EC DECLARATION OF CONFORMITY
Notified Body 0044 : TÜV NORD CERT GmbH, Langemarckstr. 20, 45141, Essen, Germany EC-type examination certificate No. 44 205 13 099217 For technical document,see European Subsidiary
A. Maekawa General Manager OPTEX CO., LTD. Quality Control Dept.
DIN 18650-1:2010 Chapter 5.7.4 ESPE
EN 12978:2003 +A1:2009 EN ISO 13849-1:2008/AC:2009 EN ISO 13849-2:2012
Machinery Directive 2006/42/ECEN 16005:2012 Chapter 4.6.8 and Annex C EMC Directive 2004/108/EC EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3 EN 61000-6-2:2005 EN 61000-6-3:2007 +A1:2011
B
C
D
E
F
G
H
I
J
BLUEZONE
(1st row)
2nd row 3rd row 4th row 5th row 6th row
FLEX EYE
A
X
DETECTION AREA
The actual detection area may become smaller depending on the ambient light, the color / material of the object or the floor as well as the entry speed of the object. The sensor may not be activated when the entering speed of the object or a person is slower than 50mm / sec. or faster than 1500mm / sec.
NOTE
[ m (feet,inch) ]
Charts show the values in the following area angle adjustment settings ; Depth : 8° Width : 0°
: Emitting spots : Emitting spots
(can be eliminated)
Test conditions required by EN 16005
The values above are those of the Detection area when tested referring to the test conditions of EN 16005. (The emitting area is as shown in Emitting area above.)
To comply with EN 16005, make sure that the detection area is within the values of the chart below.
Detection area
A X H J
2.30 (7'7")2.00 (6'7")
0.24 (9")
0.85 (2'9")
2.01 (6'7")
0.25 (10")
0.91 (2'12")
2.20 (7'3")
2.50 (8'2")
0.23 (9")
0.96 (3'2")
2.44 (8')
Floor :Grey paper Detection object : EN 16005 CA reference body Sensitivity : High Speed of detection object : 50mm / sec.
: Detection Area
Emitting area
B C D E F
G
H
I
J
A
2.00 2.30 2.50
0.38 0.46 0.50
2.06 2.48 2.69
1.49 1.80 1.95
0.92 1.11 1.20
1.75 2.11 2.29
1.34 1.62 1.76
0.84 1.01 1.09
0.71 0.86 0.94
0.13
(6
'7"
)
(1
'3"
)
(6
'9"
)
(4
'11"
)
(3
'
)
(5
'9"
)
(4
'5"
)
(2
'9"
)
(2
'4"
)
(5") 0.16
(7
'7"
)
(1
'6"
)
(8
'2"
)
(5
'11"
)
(3
'8"
)
(6
'11"
)
(5
'4"
)
(3
'4"
)
(2
'10"
)
(6") 0.17
(8
'2"
)
(1
'8"
)
(8
'10"
)
(6
'5"
)
(3
'11"
)
(7
'6"
)
(5
'9"
)
(3
'7"
)
(3
'1"
)
(7")
FLEX EYE
BLUEZONE BLUEZONE
FLEX EYE
KnockoutKnockout
NOTE
Do not touch the dipswitches before turning the power ON, otherwise an error occurs. When changing the settings of dipswitch, see ADJUSTMENTS 4. Dipswitch settings
ø
83 (ø3 4/16")
1
ADJUSTMENTS
Dipswitch settings
Area angle adjustment
FLEX EYE angle adjustment
4
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When the operation indicator blinks Green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
WARNING
1. When turning the power ON, always walk-test the detection area to ensure the proper operation.
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
*1
: Activation output shows the status of when FLEX EYE mode is enabled. (Dipswitch 14 is set to "ON".)
*2
: When dipswitch 15 is set to "ON".
NOTE
NOTE
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
CHECKING
Outside of
detection area
Entry
Entry to
4th to 6th row
Entry to 3rd row
Entry to 2nd row
Entry to
FLEX EYE
only
Entry to
FLEX EYE
and
2nd to 4th row
Entry to
BLUEZONE
(*2)
Power off
Outside of
detection area
Check the operation according to the chart below.
ON
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
Image
Operation
indicator
None
Green
Green
Orange Red Red Blinking Purple
Fast Purple
Blinking
Blue
Activation output (
*1)
Safety
output
Safety
output
Entry
Image
Operation
indicator
1-2.Area width angle adjustment
The angle of the detection area can both be moved 7° either left or right in 2 steps.
[m(feet,inch)]
[m(feet,inch)]
1-1.Area depth angle adjustment
Left
Right
Deep
Shallow
6°×7 6°×7
+2°-14°
3-1.FLEX EYE width angle adjustment
Make sure to adjust the FLEX EYE angle depending on the door type and the intended touchless plate position otherwise the sensor may not detect when a hand is approached.
Double slide door Single slide door
1 2 7 8
Left
eliminated
Right
eliminated
3-2.FLEX EYE depth angle adjustment
After adjusting the angle, make sure that the FLEX EYE is placed on the proper position for your use. Affix the touchless plate on the appropriate position after adjusting the FLEX EYE.
Make sure to affix the touchless plate where a hand is not caught by the door during door opening and closing.
CAUTION
Risk of getting caught.
NOTE
NOTE
NOTE
3
Area width adjustment2
The presence timer is applied to BLUEZONE(1st row), 2nd row and 3rd row. The presence timer can be selected from 4 settings.
When using more than one sensor close to each other, set the frequency different for each sensor.
Set the depth rows with dipswitches 6 and 7.
Row adjustment
BLUEZONE
(1st row)
Function
Dipswitch
1
Dipswitch
2
Dipswitch
3
Dipswitch
4
Dipswitch
5
Dipswitch
6
Dipswitch
7
Dipswitch
8
Dipswitch
9
Dipswitch
10
Dipswitch
11
Dipswitch
12
Set the detection area sensitivity according to the mounting height.
Setting
Comment
Installation mode
Set dipswitch 16 to "ON" to adjust the 2nd row. During the installation mode only the 2nd row remains active and the operation indicator shows yellow. After setting the row switch dipswitch 16 "OFF".
Dipswitch
16
Sensitivity
Dipswitch settings table
Presence timer
Frequency
Immunity
Activation output
When dipswitch 15 is set to "ON", the BLUEZONE (1st row) is active and looks through the threshold.
Adjust sensitivity for FLEX EYE.
Select the FLEX EYE mode "ON" or "OFF". ON : Activation output is emitted when a detection occurs in FLEX EYE and the 2nd to 4th row. OFF : Activation output is emitted when a detection occurs in the 2nd to 6th row.
32
30sec.3260sec.
32
180sec. 600sec.
32
A54B54C
54
D
54
6rows675rows674rows673rows
67
ON
8
OFF
8
High
1
Low
1
N.C.
9
N.O.
9
Self Monitoring
Disable
10
Enable
10
Safety output
Low
11
High
11
Safety input
Low
12
High
12
Dipswitch
13
FLEX EYE
Sensitivity
High
13
Low
13
Dipswitch
14
Dipswitch
15
FLEX EYE
mode
OFF
14
ON
14
ON
15
OFF
15
ON
16
OFF
16
Set dipswitch 8 to "ON" when the sensor operates by itself (Ghosting).
Dipswitch 9 is for the Activation output to door controller.
Dipswitch 11 is for the Safety output (to door controller).
Dipswitch 12 is for the Safety input (from door controller).
When the door remains open and the operation indicator shows Fast/Slow Green Blinking, refer to TROUBLESHOOTING. If the door still remains open, set dipswitch 10 to "Disable".To comply with EN 16005, set dipswitch 10 to "Enable".
Area depth adjustment with INFRARED FINDER (Separately available)
INFRARED FINDER
Detection area
Detection area
1.Turn the depth angle adjustment screw to the right (Deep) to place the detection area most away from the door.
2. Set INFRARED FINDER sensitivity to "H" (High) and place it on the floor as shown below.
3. Turn the depth angle adjustment screw to the left (Shallow) until the emitting area is placed at the position where INFRARED FINDER is in the low detection status (Slow Red Blinking).
REFERENCE
Left Right
Adjust the detection area width with the adjustment screws.
When setting the detection area width, make sure to turn the adjustment screws until it clicks. cannot be eliminated separately, neither can
7
8
1
2
Make sure that the detection area does not overlap with the door / header, and there is no highly reflecting object near the detection area otherwise ghosting / signal saturation may occur.
When adjusting the 2nd row close to the door, see dipswitch 16 in Dipswitch settings table and REFERENCE for the easier adjustment.
Deep
Operation indicator :
Purple
Shallow
High
11
Low
11
ON
ON
OFF
OFF
N.O.
9
N.C.
9
High
11
Low
11
N.O.
9
N.C.
9
Activation output (
*1)
ON
OFF
After changing the dipswitch settings, make sure to push the function switch for 2 seconds.
push 2 seconds
[m(feet,inch)]
1 2 3 4 5 6 7 8
Front view
2.0(6'7")
2.5(8
'2"
)
2.0
(6'7")
2.0
(6'7")
1.0
(3'3")
1.0
(3'3")
0
2.0(6'7")
2.5(8
'2"
)
3.0
(9
'10"
)
2.0
(6'7")
1.0
(3'3")
0
[m(feet,inch)]
[m(feet,inch)]
2.0(6'7")
2.5(8
'2"
)
2.0
(6
'7"
)
1.0
(3'3")
-1.0 (3'3")
0
[m(feet,inch)]
2.0(6'7")
2.5(8
'2"
)
2.0
(6
'7"
)
1.0
(3'3")
1.0
(3'3")
0
[m(feet,inch)]
2.0(6'7")
2.5(8
'2"
)
2.0
(6
'7"
)
1.0
(3'3")
1.0
(3'3")
0
TROUBLESHOOTING
Deep
-8° +8°
Shallow
3.5°×2
3.5°×2
Left
Right
* : After changing the dipswitch settings, make sure to push the function switch for 2 seconds.
Unstable
Waterdrops on the detection window. Use the rain-cover (Separately available).
Wipe the detection window with a damp cloth. Do not use any cleaner or solvent. Install in a place keeping the waterdrops off.
The detection area overlaps with that ofanother sensor.
Check ADJUSTMENT 4 dipswitch 4,5.(*)
Check ADJUSTMENT 4 dipswitch 14.(*)
Check ADJUSTMENT 4 dipswitch 9,11,12.(*)
Objects that move or emit light in the detection area.
Remove the objects.
The detection area overlaps with the door/header. Adjust the detection area to "Deep"(Outside). Sensitivity of detection area is too high. Set the detection area sensitivity lower.
Wrong wiring or connection failure. FLEX EYE function is not working.
(Dipswitch 15 is up side position)
Check the wires and connector.
Door operation
Operation
indicator
Possible cause Possible countermeasures
None
Wrong power supply voltage.
Set to the stated voltage.
Wrong wiring or connection failure. Check the wires and connector.
Check ADJUSTMENT 1,2,3.(*)
Door does not open when a person enters the detection area and FLEX EYE.
Unstable
Wrong detection area(2nd to 4th row) and FLEX EYE positioning.
Sensitivity of detection area(2nd to 4th row) is too low.
Set the detection area sensitivity higher.
Short presence timer. Set the presence timer longer.
Proper
Dirty detection window.
Wipe the detection window with a damp cloth. Do not use any cleaner or solvent.
Door opens when a person enters the detection area.
Proper
Sensitivity of FLEX EYE is too low. Set the FLEX EYE sensitivity higher.
Sensitivity of FLEX EYE is too high. Set the FLEX EYE sensitivity lower.
Proper
Wrong setting of dipswitches.
Sensor failure.
Wrong wiring or connection failure. Check the wires and connector.
Dirty detection window. Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Sensitivity of detection area is too low. Set the detection area sensitivity higher.
Contact your installer or service engineer.
Door remains open
Sudden change in the detection area. Check ADJUSTMENT 4 dipswitch 1 to 3.(*)
If the problem still persists, hard-reset the sensor.(Turn the power OFF and ON again.)
Slow
Green
Blinking
Proper
Proper operation
Installation mode is set to "ON". Set dipswitch 16 to
"
OFF".(*)
Yellow
Sensitivity of FLEX EYE is too low. Set the FLEX EYE sensitivity higher.
Slow
Purple
Blinking
Remove highly reflecting objects from the FLEX EYE. Lower the FLEX EYE sensitivity. Change the area depth angle for FLEX EYE.
Signal saturation. (FLEX EYE)
FLEX EYE overlaps with the header. Adjust FLEX EYE to "Deep" (Outside).
Fast
Green
Blinking
Door opens when no one is in the detection area. (Ghosting)
Remove highly reflecting objects from the detection area. Lower the sensitivity.(*) Change the area depth angle.
Signal saturation.
(4th, 5th, 6th row and/or BLUEZONE)
Others Set dipswitch 8 to "ON".(*)
Signal saturation. (2nd and/or 3rd row)
The detection area overlaps with the door/header. Adjust the detection area to "Deep" (Outside).
Slow
Green
Blinking
Remove highly reflecting objects from the detection area. Lower the sensitivity.(*) Change the area depth angle.
Setting error.
Red & Green
Blinking
After changing the dipswitch settings, make sure to push the function switch for 2 seconds.
OPTEX Co.,LTD.
Manufacturer
5-8-12 Ogoto Otsu 520-0101, Japan TEL.: +81(0)77 579 8700 FAX.: +81(0)77 579 7030 WEBSITE: www.optex.co.jp/as/eng/index.html
OPTEX Technologies B.V.
European Subsidiary
Henricuskade 17, 2497 NB The Hague, The Netherlands TEL.: +31(0)70 419 41 00 FAX.: +31(0)70 317 73 21 E-MAIL: info@optex.eu WEBSITE: www.optex.eu
1.1
(3'7")
0.08 (3")
0.08 (3")
1.1
(3
'
7
"
)
5923710 MAY 2015
MANUFACTURER'S STATEMENT
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise it may cause electric shock or breakdown of the equipment.
Danger of electric shock.
WARNING
NOTE
Disregard of warning may cause the improper operation causing death or serious injury of a person.
Special attention is required to the section of this symbol.
Disregard of caution may cause the improper operation causing injury of a person or damage to objects.
NOTE
Read this operation manual carefully before use to ensure proper operation of this product. Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the changed settings and the date shall be registered in the maintenance logbook accompanying the door.
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door.
-Wet floor.
-Vibrating header or mounting surface.
-Moving objects or objects that emit light near the detection area.
-Highly reflecting floor or highly reflecting objects around the door.
NOTE
1
CAUTION
Risk of getting caught.
Make sure to affix the mounting template as described in the above chart , otherwise it can be dangerous since there may be no detection area around the threshold. Install the sensor as low as possible on the header.
H : Height from the floor to the bottom of the header Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
(The mounting height is "H + Y".)
Maximum mounting distance (Y)
X
H
Y
Sensor
Door
Header
Floor
X
6'7" (2.00)
7'7" (2.30) 8'2" (2.50)
9'2" (2.80)
0
No limit
2" (0.05)
8" (0.20) 8" (0.20)
8" (0.20)
4" (0.10) 8" (0.20)
8" (0.20) 8" (0.20)
8" (0.20)
6" (0.15) 5" (0.13)
6" (0.15) 7" (0.19)
8" (0.20)
8" (0.20)
-
5" (0.12) 6" (0.14)
6" (0.15)
10" (0.25)
5" (0.12)
12" (0.30) -
-
H
8" (0.20)
-
--
- 4" (0.11)
[feet,inch (m)]
9'10" (3.00)
0 0 0 0 0
-
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø1/8" (ø3.4mm).
3. To pass the cable through the header, drill a wiring hole of ø3/8" (ø10mm).
4. Remove the mounting template.
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
NOTE
Make sure not to mount the sensor lower than the bottom of header.
WARNING
Danger of electric shock.
Do not use the sensor without the cover. When using the cable knockout, install the sensor indoors or use the rain-cover (Separately available) otherwise electric shock or breakdown of the sensor may occur.
4
Place the housing cover. If wiring is to be exposed, break the knockout.
Wire the Power & Primary Activation output cable and Secondary Activation output cable to the door controller properly as shown in the drawing below. The Secondary Activation output requires an input at the door control that is inhibited(ignored) when the door controller has a safety beam input.If not then install a position / inhibit switch in series with the blue wire output(see drawing below).
Power &
Primary Activation
output cable
Secondary
Activation
output cable
Activate input
Power supply
Secondary
Activation
output
Power
Inhibit switch status
Primary Activation output
Yellow
Grey
AIR-SLIDE 2
Inhibit switch
when door
is closed
Door controller
Blue
Grey
Door controller without
safety beam input
Door controller
with
safety beam input
2
3
BLUEZONE
When dipswitch 11 is set to ON, the BLUEZONE area, that provides extra safety over the threshold, is activated. In case the BLUEZONE function is not required, set dipswitch 11 to OFF. Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 11.
BLUEZONE (1st row)
2nd row
3rd row
BLUEZONE (1st row)
2nd row
3rd row
INSTALLATION
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches. (See ADJUSTMENTS 4. Dipswitch settings)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON. When turning the power ON or after adjusting the settings, do not enter the detection area for more than 10 seconds in order to enable the presence detection.
AIR-SLIDE 2
KnockoutKnockout
Dipswitch 15 can adjust the FLEX EYE function ON or OFF.
- FLEX EYE mode ON.(Dipswitch 15 OFF)
- FLEX EYE mode OFF.(Dipswitch 15 ON) You can use AIR-SLIDE 2 as normal Autodoor activation sensor. You do not need to adjust FLEX EYE function.
During FLEX EYE and Secondary Activation area are both working, Primary Activation output is emited. When only one function is working, Primary Activation output is not emited.
FLEX EYE MODE
FLEX EYE
Secondary
Activation area
OUTER DIMENSIONS AND PART NAMES
(2) Secondary Activation output Connector
(1) Power & Primary Activation output Connector (3) Mounting holes
(4) Operation indicator
(8) Secondary Activation area angle adjustment screw (9) Secondary Activation area width adjustment screws
(5) FLEX EYE Width angle adjustment screw (6) FLEX EYE Depth angle adjustment screw (7) Dipswitches
(10) Detection window (11) Area adjustment tool
Touchless plate
9 10/16” (245) 1 7/16” (37)
5/16” (7.5)
2 11/16” (68)
1 7/16” (36) 1 11/16” (43)
4 15/16” (125)
4” (102)
4” (102)
(1) (2) (3)
(4) (9)(8)(5) (6) (7) (10)
(11)
This sensor is designed to detect a hand approaching to a touchless plate as a knowing act activation device. Please make sure to understand the following working principle. This sensor sends primary activation output when both "FLEX EYE and 2nd to 4th row" detect some object. After the detection until the door fully closes, 2nd to 6th rows work as a Secondary Activation output. "FLEX EYE" means a detection area for the hand. Secondary Activation area is from the 2nd row to the 6th row.
BLUEZONE
(1st row) 2nd row 3rd row 4th row 5th row 6th row
FLEX EYE
123456
FLEX EYE
123456
FLEX EYE
WORKING PRINCIPLE
Model Cover color Mounting height Detection area Detection method FLEX EYE angle adjustment
Power supply Power consumption
Operation indicator Primary, Secondary Activation output
: AIR-SLIDE 2 : Black : 6'7"(2.0m) to 9'10"(3.0m) : See DETECTION AREA : Active infrared reflection(*1) : Depth : -14° to +2° Width : ±42° ( 7 clicks with 6°every one click-Reft/Light )
: < 2.0W (< 3VA at AC) : See Operation indicator table
Output hold time Operating temperature
Operating humidity IP rate Weight Accessories
: Approx. 0.5 sec.
Response time : < 0.3 sec.
: -4 to 131°F (-20 to +55°C) : <80% : IP44 : 8.8oz (250g) : 1 Operation manual 2 Mounting screws 1 Mounting template
The specifications herein are subject to change without prior notice due to improvements.
NOTE
*1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function. *2 : See BLUEZONE *3 : See FLEX EYE MODE
SPECIFICATIONS
1 Area adjustment tool 1 Power & Primary Activation output cable 8'2" (2.5m) 1 Secondary Activation output cable 8'2" (2.5m)
Secondary Activation area angle adjustment
Width : ±7° ( 2 clicks with 3.5°every one click-Reft/Light )
: Depth : -16° to +0°
: Form A relay 50V 0.3A Max. (Resistance load)
: 12 to 24V AC ±10% (50/60Hz) 12 to 30V DC ±10%
Operation indicator table
1sec. 1sec.
Status
Stand-by (Operation mode)
Set-up
BLUEZONE (1st row) detection (*2)
2nd row detection 3rd row detection
4th-6th row detection
Operation indicator color
Yellow Blinking
Green
Blue
Red Blinking
Red
Orange
Signal saturation(Secondary Activation area)
Signal saturation (FLEX EYE)
Sensor failure
Slow Green Blinking Slow Purple Blinking Fast Green Blinking
Stand-by (Installation mode) Yellow
FLEX EYE detection (*3)
FLEX EYE & 2nd-4th row detection
Fast Purple Blinking
Purple
B
C
D
E
F
G
H
I
J
BLUEZONE
(1st row)
2nd row 3rd row 4th row 5th row 6th row
FLEX EYE
A
DETECTION AREA
The actual Secondary Activation area may become smaller depending on the ambient light, the color / material of the object or the floor as well as the entry speed of the object. The sensor may not be activated when the entering speed of the object or a person is slower than 50mm / sec. or faster than 1500mm / sec.
NOTE
B C D E F G H
I
J
A
[ feet,inch (m) ]
6’7” (2.00) 7’7” (2.30) 8’2” (2.50) 9’10”(3.00)
1’8” (0.45) 1’8” (0.52) 1’10” (0.56) 2’3”(0.68)
7’5” (2.26) 8’6” (2.60) 9’3” (2.82) 11’1”(3.39)
5’8” (1.72) 6’6” (1.98) 7’11” (2.15) 8’6”(2.59)
3’5” (1.04) 3’11” (1.20) 4’8” (1.43) 5’1”(1.56)
6’7” (2.00) 7’7” (2.30) 8’2” (2.50) 9’11”(3.01)
5’ (1.53) 5’9” (1.76) 6’4” (1.92) 7’7”(2.30)
3’7” (1.09) 4’1” (1.25) 4’6” (1.36) 5’4”(1.63)
2’7” (0.80) 3’ (0.92) 3’4” (1.01) 3’12”(1.21)
8” (0.20) 9” (0.23) 10” (0.26) 1’(0.31)
Charts show the values in the following Secondary Activation area angle adjustment settings ; Depth :0° Width :0°
Secondary
Activation
output
Power Primary Activation output
AIR-SLIDE 2
: Emitting spots : Emitting spots
(can be eliminated)
1
ADJUSTMENTS
Dipswitch settings
Secondary Activation area angle adjustment
FLEX EYE angle adjustment
4
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When the operation indicator blinks Green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
WARNING
1. When turning the power ON, always walk-test the detection area to ensure the proper operation.
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
NOTE
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
CHECKING
Outside of
detection area
Entry
Entry to
4th to 6th row
Entry to 3rd row
Entry to 2nd row
Entry to
FLEX EYE
only
Entry to
FLEX EYE
and
2nd to 4th row
Entry to
BLUEZONE
Power off
Outside of
detection area
No output is made when sensor detects an object in the BLUEZONE(1st row).
Check the operation according to the chart below.
ON
ON
ON
ONON
OFF OFF OFF
OFF
OFF
ON
OFF OFF
OFF
OFF
OFF
OFF
ON
Image
Operation
indicator
None
Green
Green
Orange Red Red Blinking Purple
Purple BlinkingBlue
Primary Activation
output
Secondary
Activation
output
Primary Activation
output
Secondary
Activation
output
Entry
Image
Operation
indicator
6’7” (2.0)
9’10”
(3.0)
6’7” (2.0)
3’3”
(1.0)
3’3” (1.0)
0
6’7” (2.0)
9’10” (3.0)
6’7” (2.0)
3’3”
(1.0)
3’3” (1.0)
0
1-2.Secondary Activation area width angle adjustment
The width of the activation Secondary Activation area can both be moved at the same time 7° either left or right in 2 step.
[feet,inch(m)]
[feet,inch(mm)]
[feet,inch(mm)]
[feet,inch(m)][feet,inch(m)]
6’7” (2.0)
9’10” (3.0)
6’7”
(2.0)
6’7”
(2.0)
3’3” (1.0)
3’3”
(1.0)
0
1 2 3 4 5 6 7 8
6’7” (2.0)
9’10”
(3.0)
9’10”
(3.0)
6’7” (2.0)
3’3”
(1.0)
0
[feet,inch(m)] [feet,inch(m)]
6’7” (2.0)
9’10”
(3.0)
6’7” (2.0)
3’3” (1.0)
3’3”
(1.0)
0
1-1.Secondary Activation area depth angle adjustment
Deep
Shallow
+2°-14°
3-1.FLEX EYE width adjustment
Make sure to select the FLEX EYE angle depending on the door type and the intended touchless plate position otherwise the sensor does not send an output when a hand is waved.
Double slide door Single slide door
1 2 7 8
Left
eliminated
Right
eliminated
3-2.FLEX EYE Depth adjustment
3-3.Affix the touchless plate on the appropriate position after adjusting the FLEX EYE.
After adjust the angle, please check the FLEX EYE is on the best position for your use. Please check the door will be open, when you are detected in the area between 2nd to 4th row. Operation indicator color will be purple, when all the adjustment are OK.
Make sure to affix the touchless plate where a head is not caught by the door during door closing.
CAUTION
Risk of getting caught.
NOTE
NOTE
NOTE
3
Secondary Activation area width elimination2
NOTE
All rows have the presence detection function. The presence timer can be selected from 4 settings.
When using more than one sensor close to each other, set the frequency different for each sensor.
Set the depth rows with dipswitches 9 and 10.
When dipswitch 11 is set to ON, the BLUEZONE (1st row) is active and looks through the threshold.
Row adjustment
BLUEZONE
(1st row)
Secondary
Activation output
FLEX EYE Sensitivity
Function
Dipswitch
1
Dipswitch
2
Dipswitch
3
Dipswitch
4
Dipswitch
5
Dipswitch
6
Dipswitch
7
Dipswitch
8
Dipswitch
9
Dipswitch
10
Dipswitch
11
Dipswitch
12
Dipswitch
13
Dipswitch
14
Dipswitch
15
Set the sensitivity according to the mounting height. Values below dipswitch are reference only.
Setting
Comment
Set this switch to Rain if the sensor is used in a region with a lot of rain.
Set this switch to Snow if the sensor is used in a region with snow or a lot of insects.
6’7” to 8’2”
21
Low
43
30sec.
Setting1
65
6’7” to 8’2”
21
Middle
43
60sec.
Setting2
65
7’7” to 8’10”
21
High
43
180sec.
Setting3
65
8’2” to 9’10”
21
S-High
43
600sec.
Setting4
65
Normal
7
Rain
7
Normal
8
Snow
8
Set dipswitch 16 to ON to adjust the 2nd row. During the installation mode only the 2nd row remains active and the operation indicator shows yellow. After setting the row switch dipswitch 16 OFF.
Installation mode
Dipswitch
16
OFF
11
ON
11
N.O.12N.C.
12
OFF
15
ON
15
OFF16ON
16
Secondary
Activation area
Sensitivity
Dipswitch settings table
Presence timer
FLEX EYE mode
Frequency
Rain mode
Snow mode
Select "N.O."/"N.C." for Secondary Activation output.
Adjust sensitivity for “FLEX EYE” detection.
Select the FLEX EYE mode ON or OFF. See FLEX EYE MODE.
Low
1413
Middle
1413
High
1413
S-High
1413
6rows
910
5rows
910
4rows
910
3rows
910
Unstable
TROUBLESHOOTING
Waterdrops on the detection window. Use the rain-cover (Separately available).
Or wipe the detection window with a damp cloth. Do not use any cleaner or solvent. Or install in a place keeping the waterdrops off.
The Secondary Activation area overlaps with that ofanother sensor.
Check ADJUSTMENT 1. Or change Frequency setting.
Check FLEX EYE MODE.
Check ADJUSTMENT 4.
Objects that move or emit light in the Secondary Activation area.
Remove the objects.
The Secondary Activation area overlaps with the door/header.
Adjust the Secondary Activation area to "Deep" (Outside).
Sensitivity of Secondary Activation area is too high.
Set the Secondary Activation area sensitivity lower.
Wrong wiring or connection failure. FLEX EYE function is working.
(Dipswitch 15 is down side position)
Check the wires and connector.
Door operation
Operation
indicator
Possible cause Possible countermeasures
None
Wrong power supply voltage.
Set to the stated voltage.
Wrong wiring or connection failure. Check the wires and connector.
Check ADJUSTMENT 1.
Door does not open when a person enters the Secondary Activation area.
Unstable Wrong Secondary Activation area
positioning. Sensitivity of Secondary Activation area
is too low.
Set the Secondary Activation area sensitivity higher.
Short presence timer. Set the presence timer longer.
Proper
Dirty detection window. Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Sensitivity of FLEX EYE is too low. Set the FLEX EYE sensitivity higher.
Sensitivity of FLEX EYE is too high. Set the FLEX EYE sensitivity lower.
Proper Wrong setting of dipswitches.
Sensor failure.
Wrong wiring or connection failure. Check the wires and connector.
Dirty detection window. Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Sensitivity of Secondary Activation area is too low.
Set the Secondary Activation area sensitivity higher.
Contact your installer or service engineer.
Adjust the Secondary Activation area to "Deep" (Outside).
Door remains open
Sudden change in the Secondary Activation area.
Check ADJUSTMENT 1. If the problem still persists, hard-reset the sensor. (Turn the power OFF and ON again.)
Slow
Green
Blinking
Remove highly reflecting objects from the Secondary Activation area. Or lower the Secondary Activation area sensitivity. Or change the area depth angle for Secondary Activation.
Proper
Proper operation
Installation mode is set to "ON".
Set dipswitch 16 to
"
OFF
"
.
Yellow
Sensitivity of FLEX EYE is too low. Set the FLEX EYE sensitivity higher.
Signal saturation. (Secondary Activation area)
Secondary Activation area overlaps with the door/header.
Slow
Purple
Blinking
Remove highly reflecting objects from the FLEX EYE. Or lower the FLEX EYE sensitivity. Or change the area depth angle for FLEX EYE.
Signal saturation. (FLEX EYE)
FLEX EYE overlaps with the header.
Access setting website from here.
Adjust FLEX EYE to "Deep" (Outside).
Fast
Green
Blinking
Door opens when no one is in the Secondary Activation area. (Ghosting)
INFRARED FINDER
Secondary Activation area
Secondary Activation area
1.Turn the depth angle adjustment screw to the right (Deep) to place the Secondary Activation area most away from the door.
2. Set INFRARED FINDER sensitivity to "H" (High) and place it on the floor as shown below.
Area depth adjustment with INFRARED FINDER (Separately available)
REFERENCE
3. Turn the depth angle adjustment screw to the left (Shallow) until the emitting area is placed at the position where INFRARED FINDER is in the low detection status (Slow Red Blinking).
OPTEX Co.,LTD.
Manufacturer
5-8-12 Ogoto Otsu 520-0101, Japan TEL.: +81(0)77-579-8700 FAX.: +81(0)77-579-7030 WEBSITE: www.optex.co.jp/as/eng/index.html
East coast office
8510 McAlpines Park Drive, Suite 108 Charlotte, NC 28211 U.S.A. TEL.: +1-800-877-6656 FAX.: +1(704)365-0818 WEBSITE: www.optextechnologies.com
OPTEX INCORPORATED
North and South America Subsidiary
18730 S. Wilmington Avenue, Suite 100 Rancho Dominguez CA 90220 U.S.A TEL.: +1-800-877-6656 FAX.: +1(310)214-8655 WEBSITE: www.optextechnologies.com
3’ 7”
(1100)
3”
(80)3”(80)
Left
7° to Left
Front view
Deep
-16°
Shallow
Right
Left Right
7° to Right
To adjust the Secondary Activation area width, use the adjustment screws.
When setting the Secondary Activation area width, make sure to turn the adjustment screws until it clicks. cannot be eliminated separately, neither can
7
8
1
2
Make sure that the Secondary Activation area does not overlap with the door / header, and there is no highly reflecting object near the detection area otherwise ghosting / signal saturation may occur.
When adjusting the 2nd row close to the door, see Dipswtich settings table dipswitch16 for the easier adjustment.
Deep
Operation indicator :
Purple
Shallow
3’7”
(1100)
N.O.
12
N.C.
12
N.O.
12
N.C.
12