Optex OA-72C Specsheet

Ceiling-mount
Door Sensor
C
2
7
-
A
O
Quality Easy Adjustment Presence Detection
Flexible Concealed
SafetyCeiling mounted
The OPTEX OA-72C Active Infrared Sensor is
a ceiling-mount type sensor for automatic
doors. Its stylish design and flexible detection
area setting fit to any existing entrance.
Safe and Stable Operation
The OPTEX OA-72C has the ability to detect the pres-
ence of a person or object within its field of view, thus keeping the door open anytime someone is near. The presence timer can be adjusted for 2, 30 or 60 seconds. In addition, snow mode is built-in to add stability in locations where the sensor is exposed to harsh envi­ronments.
Flexible Detection Area
Adjust the detection area Left and Right and move it
closer or farther away from the door. Adjustment is ac­complished by the movement of independent thresh­old and approach areas. Fine adjusters allow for ad­justment within 1 inch of the moving face of the door.
High Mount Capability
High ceilings are not a problem for the OA-72C. The sensor can be mounted as high as 13 feet above the floor.
Ceiling-mount Door Sensor
Model Cover color Mounting height Detection method Detection angle adjustment
Specifications
Wide angle adjustment Power supply
Power consumption Operation LED
Output
Output hold time Response time Operating temperature Weight Accessories
OPTEX Inc.
Americas Headquarters 18730 S. Wilmington Ave, Unit 100 Rancho Dominguez, CA 90220 Ph 310 214-8644 Fax 310 214-8655 Toll free 800 877-6656
OA-72C Silver
2.0 m (6’7”) to 4.0 m (13’1”) Active Infrared reflection
-15° to +10°
-10° to +10° 12 to 24V AC (±10%) 12 to 30V DC (±10%) <1.5 W (<5 VA at AC) Green: stand-by Red: 1st row detection Orange: 2nd to 5th row detection Form C relay 50V 0.3A max. (resis­tance load) Approx. 0.5 sec. <0.3 sec.
-4°F to 131°F 320g (11.2 oz.) 3 m (9’10”) connection cable, mounting template, operation manual
(East Coast Office) 8510 McAlpine Park Dr., Suite 108 Charlotte, NC 28211
www.optexamerica.com
Easy Installation
The OA-72C comes with built-in mounting flanges.
Simply cut the hole, connect the wires and pop the sensor into place.
Detection Area Chart
Dimensions in this chart are based on factory default settings and sensor mounted 11 3/4” from face of moving panel to center of sensor.
Mounting Height A 8’ 2” 9’ 10” 11’ 6” 13’ 1”
Area Depth B
Area Depth C
Area Depth D 2’ 4” 2’ 10” 3’ 4” 3’ 10”2’ 1”
Area Depth E 3’ 6” 4’ 2” 4’ 11” 5’ 7”3’ 1”
Area Depth F
Area Width G
Area Width H
Area Width I
The actual detection area may vary slightly based upon environmental conditions. Installer must perform walk test to verify conformance with minimum requirement of the current ANSI Standard.
7’ 3”
5.9” 7.1” 8.3” 9.24”5.1”
1’ 5” 1’ 8” 2’ 2’ 3”1’ 3”
4’ 8” 5’ 7” 6’ 6” 7’ 5”4’ 1”
4’ 1” 4’ 10” 5’ 8” 6’ 6”3’ 7”
6’ 2” 7’ 5” 8’ 8” 9’ 10”5’ 5”
8’ 5” 10’ 1” 11’ 9” 13’ 5”7’ 5”